Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study

被引:25
|
作者
Yan, Shuang G. [1 ,2 ]
Chevalier, Yan [2 ]
Liu, Fanxiao [2 ,3 ]
Hua, Xingyi [1 ]
Schreiner, Anna [4 ]
Jansson, Volkmar [2 ]
Schmidutz, Florian [2 ,4 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, 1 Baicao Rd, Hefei 230088, Peoples R China
[2] Univ Munich LMU, Dept Orthopaed Surg Phys Med & Rehabil, Munich, Germany
[3] Shandong First Med Univ, Shandong Prov Hosp, Dept Orthopaed, 324 Rd Jing Wu Wei Qi, Jinan 250021, Shandong, Peoples R China
[4] Eberhard Karls Univ Tuebingen, BG Trauma Ctr Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
关键词
Stress shielding; Finite element analysis; Total hip arthroplasty; SHA; Stem; METHA SHORT STEM; PRIMARY STABILITY; DXA; AGE;
D O I
10.1186/s13018-020-02027-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Short stem total hip arthroplasty (SHA) preserves femoral bone stock and is supposed to provide a more natural load transfer compared to standard stem total hip arthroplasty (THA). As comparative biomechanical reference data are rare we used a finite element analysis (FEA) approach to compare cortical load transfer after implantations of a metaphyseal anchoring short and standard stem in native biomechanical femora. Methods The subject specific finite element models of biomechanical femora, one native and two with implanted metaphyseal anchoring SHA (Metha, B. Braun Aesculap) and standard THA (CLS, Zimmer-Biomet), were generated from computed tomography datasets. The loading configuration was performed with an axial force of 1400 N. Von Mises stress was used to investigate the change of cortical stress distribution. Results Compared to the native femur, a considerable reduction of cortical stress was recorded after implantation of SHA and standard THA. The SHA showed less reduction proximally with a significant higher metaphyseal cortical stress compared to standard THA. Moreover, the highest peak stresses were observed metaphyseal for the SHA stem while for the standard THA high stress pattern was observed more distally. Conclusions Both, short and standard THA, cause unloading of the proximal femur. However, the metaphyseal anchoring SHA features a clearly favorable pattern in terms of a lower reduction proximally and improved metaphyseal loading, while standard THA shows a higher proximal unloading and more distal load transfer. These load patterns implicate a reduced stress shielding proximally for metaphyseal anchoring SHA stems and might be able to translate in a better bone preservation.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Comparison of manual rasping and robotic milling for short metaphyseal-fitting stem implantation in total hip arthroplasty: a cadaveric study
    Lim, Seung-Jae
    Kim, Sang-Min
    Lim, Byung-Ho
    Moon, Young-Wan
    Park, Youn-Soo
    COMPUTER AIDED SURGERY, 2013, 18 (1-2) : 33 - 40
  • [22] Comparison of two metaphyseal-fitting (short) femoral stems in primary total hip arthroplasty: study protocol for a prospective randomized clinical trial with additional biomechanical testing and finite element analysis
    Tatani, I.
    Panagopoulos, A.
    Diamantakos, I.
    Sakellaropoulos, G.
    Pantelakis, Sp
    Megas, P.
    TRIALS, 2019, 20 (1)
  • [23] Comparison of two metaphyseal-fitting (short) femoral stems in primary total hip arthroplasty: study protocol for a prospective randomized clinical trial with additional biomechanical testing and finite element analysis
    I. Tatani
    A. Panagopoulos
    I. Diamantakos
    G. Sakellaropoulos
    Sp Pantelakis
    P. Megas
    Trials, 20
  • [24] Stress Analysis in Conversion Total Hip Arthroplasty: A Finite Element Analysis on Stem Length and Distal Screw Hole
    Shimasaki, Koshiro
    Nishino, Tomofumi
    Yoshizawa, Tomohiro
    Watanabe, Ryunosuke
    Hirose, Fumi
    Yasunaga, Shota
    Mishima, Hajime
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (01)
  • [25] Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty A FINITE ELEMENT ANALYSIS
    Kwak, D-K
    Bang, S-H
    Lee, S-J
    Park, J-H
    Yoo, J-H
    BONE & JOINT RESEARCH, 2021, 10 (04): : 250 - 258
  • [26] Load Dispersion Effects of Acetabular Reinforcement Devices Used in Revision Total Hip Arthroplasty A Simulation Study Using Finite Element Analysis
    Kawanabe, Keiichi
    Akiyama, Haruhiko
    Goto, Koji
    Maeno, Sumihiko
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1061 - 1066
  • [27] Long-term follow-up result of short metaphyseal femoral stem in primary total hip arthroplasty: A retrospective study
    Kumar, Manoj
    Sharma, Ayush
    Ksheerasagar, Vivek P.
    Ghosh, Akash K.
    Lal, Mukund
    WORLD JOURNAL OF ORTHOPEDICS, 2025, 16 (01):
  • [28] Analysis of the physiological load on lumbar vertebrae in patients with osteoporosis: a finite-element study
    Kang, Sungwook
    Park, Chan-Hee
    Jung, Hyunwoo
    Lee, Subum
    Min, Yu-Sun
    Kim, Chul-Hyun
    Cho, Mingoo
    Jung, Gu-Hee
    Kim, Dong-Hee
    Kim, Kyoung-Tae
    Hwang, Jong-Moon
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [29] Analysis of the physiological load on lumbar vertebrae in patients with osteoporosis: a finite-element study
    Sungwook Kang
    Chan-Hee Park
    Hyunwoo Jung
    Subum Lee
    Yu-Sun Min
    Chul-Hyun Kim
    Mingoo Cho
    Gu-Hee Jung
    Dong-Hee Kim
    Kyoung-Tae Kim
    Jong-Moon Hwang
    Scientific Reports, 12
  • [30] Static structural analysis of different stem designs used in total hip arthroplasty using finite element method
    Chethan, K. N.
    Zuber, Mohammad
    Bhat, Shyamasunder N.
    Shenoy, Satish B.
    Kini, Chandrakant R.
    HELIYON, 2019, 5 (06)