Comparison of the Accuracies of CBCT, Radiography, and Four Electronic Apex Locators in Working Length Determination

被引:0
|
作者
Ozata, Merve Yeniceri [1 ]
Falakaloglu, Seda [2 ]
Kaya, Sadullah [1 ]
机构
[1] Dicle Univ, Fac Dent, Dept Endodont, TR-21280 Diyarbakir, Turkey
[2] Afyonkarahisar Hlth Sci Univ, Fac Dent, Dept Endodont, TR-03200 Afyon, Turkey
来源
MAKARA JOURNAL OF HEALTH RESEARCH | 2022年 / 26卷 / 01期
关键词
COMPUTED-TOMOGRAPHY; TEETH; RELIABILITY; SIZE;
D O I
10.7454/msk.v26i1.1334
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: One of the significant stages during endodontic procedures is determining the correct working length (WL). This study aimed to evaluate the accuracy of four electronic apex locators (EALs) (Root ZX mini, Raypex 6, Propex Pixi, and E-Pex Pro) and cone-beam computed tomography (CBCT) and radiographic measurement in determining the actual WL (A-WL). Methods: Thirty extracted single- root mandibular premolars were selected and flattened at the crown. The WL was determined by advancing the #15 K file until its tip was visible from the apical, and the A-WL was established by subtracting 0.5 mm from this length. The WL was also determined using periapical radiography, four EALs, and CBCT. The differences in all measurements were compared with the A-WL. The data were statistically analyzed using one-way analysis of variance (Welch) and Tamhane's test. The significance level was set at p < 0.05. Results: Compared with other measurement methods, CBCT gave shorter values than the A-WL, and this finding was statistically significant compared with those of the PR and Propex Pixi groups (p = 0.009) (p = 0.024). No significant difference was observed between the other groups (p > 0.05) except the CBCT group (p < 0.05). Conclusions: Root ZX mini and Raypex 6 made measurements close to the A-WL.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [41] Influence of Open Apex on Working Length Determination Using Cone-Beam Computed Tomography and Apex Locators: A Comparative In Vitro Study
    Srivastava, Swati
    Alharbi, Hanan M.
    Soliman, Mai
    Eldwakhly, Elzahraa
    Abdelhafeez, Manal M.
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [42] Comparative study for working length determination due to digital radiography and apex locator methods
    Custódio, AF
    Davidowicz, H
    Morelli, CG
    Moura, AAM
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1002 - 1002
  • [43] In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique
    Altunbas, D.
    Kustarci, A.
    Arslan, D.
    Er, K.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2014, 17 (06) : 706 - 710
  • [44] A comparison between two electronic apex locators:: an in vivo investigation
    Venturi, M
    Breschi, L
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (01) : 36 - 45
  • [45] Accuracy of Three Electronic Apex Locators Compared with Digital Radiography: An Ex Vivo Study
    Cianconi, Luigi
    Angotti, Vincenzo
    Felici, Roberto
    Conte, Gabriele
    Mancini, Manuele
    JOURNAL OF ENDODONTICS, 2010, 36 (12) : 2003 - 2007
  • [46] Effectiveness of four electronic apex locators to determine distance from the apical foramen
    Stoll, R.
    Urban-Klein, B.
    Roggendorf, M. J.
    Jablonski-Momeni, A.
    Strauch, K.
    Frankenberger, R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (09) : 808 - 817
  • [47] Comparative Assessment of Working Length Determination: Apex Locators versus Endomotor with Built-in Apex Locator in Single-Rooted Permanent Teeth
    Chhabra, Ajay
    Prathap, B. Saravana
    Ramya, K. P.
    Yadav, Priyanka
    Mehra, Himani
    Parvathy, Sona J.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2892 - S2894
  • [48] Effect of chloroform, orange solvent and eucalyptol on the accuracy of four electronic apex locators
    Al-Hadlaq, Solaiman M.
    AUSTRALIAN ENDODONTIC JOURNAL, 2013, 39 (03) : 112 - 115
  • [49] In vitro evaluation of the ability of three apex locators to determine the working length during retreatment
    Goldberg, F
    Marroquín, BB
    Frajlich, S
    Dreyer, C
    JOURNAL OF ENDODONTICS, 2005, 31 (09) : 676 - 678
  • [50] A comparison between two electronic apex locators:: an ex vivo investigation
    Venturi, M.
    Breschi, L.