Comparison of the Accuracies of CBCT, Radiography, and Four Electronic Apex Locators in Working Length Determination

被引:0
|
作者
Ozata, Merve Yeniceri [1 ]
Falakaloglu, Seda [2 ]
Kaya, Sadullah [1 ]
机构
[1] Dicle Univ, Fac Dent, Dept Endodont, TR-21280 Diyarbakir, Turkey
[2] Afyonkarahisar Hlth Sci Univ, Fac Dent, Dept Endodont, TR-03200 Afyon, Turkey
来源
MAKARA JOURNAL OF HEALTH RESEARCH | 2022年 / 26卷 / 01期
关键词
COMPUTED-TOMOGRAPHY; TEETH; RELIABILITY; SIZE;
D O I
10.7454/msk.v26i1.1334
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: One of the significant stages during endodontic procedures is determining the correct working length (WL). This study aimed to evaluate the accuracy of four electronic apex locators (EALs) (Root ZX mini, Raypex 6, Propex Pixi, and E-Pex Pro) and cone-beam computed tomography (CBCT) and radiographic measurement in determining the actual WL (A-WL). Methods: Thirty extracted single- root mandibular premolars were selected and flattened at the crown. The WL was determined by advancing the #15 K file until its tip was visible from the apical, and the A-WL was established by subtracting 0.5 mm from this length. The WL was also determined using periapical radiography, four EALs, and CBCT. The differences in all measurements were compared with the A-WL. The data were statistically analyzed using one-way analysis of variance (Welch) and Tamhane's test. The significance level was set at p < 0.05. Results: Compared with other measurement methods, CBCT gave shorter values than the A-WL, and this finding was statistically significant compared with those of the PR and Propex Pixi groups (p = 0.009) (p = 0.024). No significant difference was observed between the other groups (p > 0.05) except the CBCT group (p < 0.05). Conclusions: Root ZX mini and Raypex 6 made measurements close to the A-WL.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [21] Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters
    Ebrahim, A. K.
    Wadachi, R.
    Suda, H.
    AUSTRALIAN DENTAL JOURNAL, 2006, 51 (03) : 258 - 262
  • [22] Accuracy of four electronic apex locators:: an in vitro evaluation
    De Moor, RJG
    Hommez, GMG
    Martens, LC
    De Boever, JG
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1999, 15 (02): : 77 - 82
  • [23] Integrated electronic apex locators for determining working length: a systematic review of in-vitro studies
    La Rosa, Giusy Rita Maria
    Angjelova, Angela
    Jovanova, Elena
    Apostolska, Sonja
    Santos, Joao Miguel
    Pedulla, Eugenio
    ODONTOLOGY, 2024,
  • [24] In vitro evaluation and comparison of four apex locators.
    Austin, BP
    White, PW
    Dhuru, VB
    Walia, HD
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2844 - 2844
  • [25] Determination of location of root perforations by electronic apex locators
    Fuss, Z
    Assooline, LS
    Kaufman, AY
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 82 (03): : 324 - 329
  • [26] An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files
    Chaudhary, Sanjeeb
    Gharti, Archana
    Adhikari, Bhawana
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2018, 10 : 75 - 82
  • [27] An ex vivo comparison of root canal length determination by three electronic apex locators at positions short of the apical foramen
    de Vasconcelos, Bruno Carvalho
    do Vale, Taina Macedo
    Teixeira de Menezes, Antonio Sergio
    Pinheiro-Junior, Elilton Cavalcante
    Vivacqua-Gomes, Nilton
    Bernardes, Ricardo Affonso
    Hungaro Duarte, Marco Antonio
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (02): : E57 - E61
  • [28] An ex vivo comparison of three electronic apex locators
    Baginska, Joanna
    Linczuk, Ewa
    Botulinski, Bartlomiej
    Kierklo, Anna
    HEALTHMED, 2012, 6 (10): : 3275 - 3280
  • [29] Comparison of two electronic apex locators on human cadavers
    Luca Marigo
    Gian Luca Gervasi
    Francesco Somma
    Giuseppe Squeo
    Raffaella Castagnola
    Clinical Oral Investigations, 2016, 20 : 1547 - 1550
  • [30] Performance of the Working Length Determination using Cone Beam Computed Tomography, Radiography and Electronic Apex Locator, in Comparisons to Actual Length
    Yildirim, Cihan
    Aktan, Ali Murat
    Karataslioglu, Emrah
    Aksoy, Fatih
    Isman, Ozlem
    Culha, Emre
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (01)