Clinical Performance of Narrow-Diameter Titanium-Zirconium Implants: A Systematic Review

被引:19
|
作者
Badran, Zahi [1 ,2 ]
Struillou, Xavier [1 ,2 ]
Strube, Nicolas [1 ]
Bourdin, David [1 ]
Dard, Michel [3 ,4 ]
Soueidan, Assem [2 ]
Hoornaert, Alain [1 ]
机构
[1] Univ Nantes, Fac Dent Surg, Dept Oral Implantol, Nantes, France
[2] CHU Nantes, Fac Dent Surg, Dept Periodontol, INSERM,U791,UIC 11, Nantes, France
[3] NYU, Coll Dent, Dept Periodontol & Implant Dent, New York, NY USA
[4] Inst Straumann, Basel, Switzerland
关键词
Roxolid; dental implant; bone augmentation; RANDOMIZED CONTROLLED-TRIAL; DENTAL IMPLANTS; FOLLOW-UP; RADIOGRAPHIC EVALUATION; MECHANICAL-PROPERTIES; DOUBLE-BLIND; GRADE IV; ALLOY; SURVIVAL; SUCCESS;
D O I
10.1097/ID.0000000000000557
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Implant-supported prosthetic rehabilitations are in constant augmentation in everyday dental practice. This is largely due to increasing demand from patients for fixed or implant-stabilized prosthesis, although they are frequently reticent to complex preimplant bone augmentation surgeries, whenever bone volume is lacking. Narrow-diameter implants (NDI; 3.5 mm) have been developed to offer relatively simple implant solutions in challenging bone-deficient sites. However, concerns regarding their mechanical properties have been raised. Special titanium-zirconium material (Ti-Zr), with superior mechanical resistance, compared with pure titanium alloys has been introduced into the market. The purpose of this systematic review was to determine the available data on clinical performance of Ti-Zr NDI.Materials and Methods:A literature search of all available clinical articles dealing with Ti-Zr NDI has been carried out. After including only prospective clinical trials, 14 papers were retrieved for thorough reviewing.Conclusion:Short-term results from preliminary clinical reports are quite promising, although the number of published studies and the follow-up periods are still insufficient to determine the real benefit of this hybrid material compared with titanium, especially when using NDI.
引用
下载
收藏
页码:316 / 323
页数:8
相关论文
共 50 条
  • [31] The Performance of Titanium-Zirconium Implants in the Elderly: A Biomechanical Comparative Study in the Minipig
    Wen, Bo
    Chen, Jiang
    Dard, Michel
    Cai, Zhiyu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (06) : 1200 - 1209
  • [32] The osseointegration behavior of titanium-zirconium implants in ovariectomized rabbits
    Wen, Bo
    Zhu, Feng
    Li, Zhen
    Zhang, Peng
    Lin, Xingnan
    Dard, Michel
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (07) : 819 - 825
  • [33] Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants
    Hanes, Brenda
    Feitosa, Sabrina
    Phasuk, Kamolphob
    Levon, John A.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 441 - 446
  • [34] Narrow-diameter implants: A restorative option for limited interdental space
    Froum, Stuart J.
    Cho, Sang-Choon
    Cho, Young Sung
    Elian, Nicolas
    Tarnow, Dennis
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2007, 27 (05) : 449 - 456
  • [35] Narrow-Diameter Implants in the Anterior Region: A Meta-analysis
    Parize, Hian Nivaldo
    Lima Bohner, Lauren Oliveira
    Gama, Lorena Tavares
    Porporatti, Andre Luis
    Mendonca Mezzomo, Luis Andre
    Martin, William Christopher
    Simek Vega Goncalves, Thais Marques
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (06) : 1347 - +
  • [36] Clinical performance of zirconium implants compared to titanium implants: a systematic review and meta-analysis of randomized controlled trials
    Duan, Chengchen
    Ye, Li
    Zhang, Mengyun
    Yang, Lei
    Li, Chunjie
    Pan, Jian
    Wu, Yingying
    Cao, Yubin
    PEERJ, 2023, 11
  • [37] Narrow-diameter implants with conical connection for restoring the posterior edentulous region
    Woo I.-H.
    Kim J.-W.
    Kang S.-Y.
    Kim Y.-H.
    Yang B.-E.
    Maxillofacial Plastic and Reconstructive Surgery, 38 (1)
  • [38] Narrow-diameter versus standard-diameter implants placed in horizontally regenerated bone in the rehabilitation of partially and completely edentulous patients: A systematic review
    Valente, Nicola Alberto
    Marchio, Vincenzo
    Troiano, Giuseppe
    Gasparro, Roberta
    Balice, Pierluigi
    Marenzi, Gaetano
    Laino, Luigi
    Sammartino, Gilberto
    Iezzi, Giovanna
    Barone, Antonio
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2022, 15 (01) : 13 - 29
  • [39] Clinical challenges of biomechanical performance of narrow-diameter implants in maxillary posterior teeth in aging patients: A finite element analysis
    Prasitwuttisak, Saranyoo
    Chantarapanich, Nattapon
    Apinyauppatham, Komsan
    Poomparnich, Kopchai
    Inglam, Samroeng
    PLOS ONE, 2024, 19 (03): : 1 - 17
  • [40] Need for lateral bone augmentation at two narrow-diameter implants: A prospective, controlled, clinical study
    Roccuzzo, Andrea
    Imber, Jean-Claude
    Jensen, Simon Storgard
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 511 - 520