Clinical Performance of Narrow-Diameter Titanium-Zirconium Implants: A Systematic Review

被引:19
|
作者
Badran, Zahi [1 ,2 ]
Struillou, Xavier [1 ,2 ]
Strube, Nicolas [1 ]
Bourdin, David [1 ]
Dard, Michel [3 ,4 ]
Soueidan, Assem [2 ]
Hoornaert, Alain [1 ]
机构
[1] Univ Nantes, Fac Dent Surg, Dept Oral Implantol, Nantes, France
[2] CHU Nantes, Fac Dent Surg, Dept Periodontol, INSERM,U791,UIC 11, Nantes, France
[3] NYU, Coll Dent, Dept Periodontol & Implant Dent, New York, NY USA
[4] Inst Straumann, Basel, Switzerland
关键词
Roxolid; dental implant; bone augmentation; RANDOMIZED CONTROLLED-TRIAL; DENTAL IMPLANTS; FOLLOW-UP; RADIOGRAPHIC EVALUATION; MECHANICAL-PROPERTIES; DOUBLE-BLIND; GRADE IV; ALLOY; SURVIVAL; SUCCESS;
D O I
10.1097/ID.0000000000000557
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Implant-supported prosthetic rehabilitations are in constant augmentation in everyday dental practice. This is largely due to increasing demand from patients for fixed or implant-stabilized prosthesis, although they are frequently reticent to complex preimplant bone augmentation surgeries, whenever bone volume is lacking. Narrow-diameter implants (NDI; 3.5 mm) have been developed to offer relatively simple implant solutions in challenging bone-deficient sites. However, concerns regarding their mechanical properties have been raised. Special titanium-zirconium material (Ti-Zr), with superior mechanical resistance, compared with pure titanium alloys has been introduced into the market. The purpose of this systematic review was to determine the available data on clinical performance of Ti-Zr NDI.Materials and Methods:A literature search of all available clinical articles dealing with Ti-Zr NDI has been carried out. After including only prospective clinical trials, 14 papers were retrieved for thorough reviewing.Conclusion:Short-term results from preliminary clinical reports are quite promising, although the number of published studies and the follow-up periods are still insufficient to determine the real benefit of this hybrid material compared with titanium, especially when using NDI.
引用
下载
收藏
页码:316 / 323
页数:8
相关论文
共 50 条
  • [41] Clinical performance of monolithic zirconia crowns on titanium-zirconium reduced-diameter implants in the molar area: Interim data at three years of a randomized controlled trial
    Zumstein, K.
    Waller, T.
    Hammerle, C. H. F.
    Jung, R. E.
    Benic, G.
    Muhlemann, S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (12) : 1354 - 1362
  • [42] Radiographic Evaluation of Narrow-Diameter Implants After 5 Years of Clinical Function: A Retrospective Study
    Geckili, Onur
    Munncu, Emre
    Bilhan, Hakan
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 : 273 - 279
  • [43] Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study
    Smeets, Ralf
    Schoellchen, Maximilian
    Gauer, Tobias
    Aarabi, Ghazal
    Assaf, Alexandre T.
    Rendenbach, Carsten
    Beck-Broichsitter, Benedicta
    Semmusch, Jan
    Sedlacik, Jan
    Heiland, Max
    Fiehler, Jens
    Siemonsen, Susanne
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (02)
  • [44] A Prospective Noninterventional Study to Evaluate Survival and Success of Reduced Diameter Implants Made From Titanium-Zirconium Alloy
    Al-Nawas, Bilal
    Domagala, Peter
    Fragola, Giuliano
    Freiberger, Philip
    Ortiz-Vigon, Alberto
    Rousseau, Paul
    Tondela, Joao
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (04) : E118 - E125
  • [45] Narrow diameter titanium-zirconium tissue-level implants supporting multi-unit FDPs in the anterior area: A 5-year prospective study
    Altuna, Pablo
    Fernandez-Villar, Sandra
    Barroso-Panella, Albert
    Ortiz-Puigpelat, Octavi
    Hernandez-Alfaro, Federico
    Nart, Jose
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (07) : 751 - 767
  • [46] The Clinical Performance of Narrow Diameter Implants Versus Regular Diameter Implants: A Meta-Analysis
    Ma, Meng
    Qi, Mengxing
    Zhang, Dongsheng
    Liu, Hongchen
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (06) : 503 - 508
  • [47] Strength of titanium-zirconium alloy implants with a conical connection after implantoplasty
    Shah, Sweety D.
    Zheng, Fengyuan
    Seghi, Robert R.
    Lee, Damian J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03): : 593 - 599
  • [48] Clinical and radiographic evaluation of early loaded narrow-diameter implants: 3 years follow-up
    Maiorana, Carlo
    King, Paul
    Quaas, Sebastian
    Sondell, Katarina
    Worsaae, Nils
    Galindo-Moreno, Pablo
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (01) : 77 - 82
  • [49] Clinical performance of narrow-diameter implants with hydrophobic and hydrophilic surfaces with mandibular implant overdentures: 1-year results of a randomized clinical trial
    Bielemann, Amalia Machado
    Schuster, Alessandra Julie
    Possebon, Anna Paula da Rosa
    Schinestsck, Andre Ribeiro
    Chagas-Junior, Otacilio Luiz
    Faot, Fernanda
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (01) : 21 - 32
  • [50] A prospective clinical study evaluating the safety and effectiveness of narrow-diameter threaded implants in the anterior region of the maxilla
    Andersen, E
    Saxegaard, E
    Knutsen, BM
    Haanæs, HR
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (02) : 217 - 224