Segmental and subsegmental pulmonary arteries: Evaluation with electron-beam versus spiral CT

被引:42
|
作者
Schoepf, UJ
Helmberger, T
Holzknecht, N
Kang, DS
Bruening, RD
Aydemir, S
Becker, CR
Muehling, O
Knez, A
Haberl, R
Reiser, MF
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Dept Biometry & Epidemiol, D-81377 Munich, Germany
[3] Univ Munich, Klinikum Grosshadern, Dept Internal Med, D-81377 Munich, Germany
[4] Kyungpook Natl Univ Hosp, Dept Diagnost Radiol, Taegu, South Korea
关键词
computed tomography (CT); comparative studies; contrast enhancement; electron beam; helical; embolism; pulmonary; pulmonary arteries;
D O I
10.1148/radiology.214.2.r00fe10433
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare contrast agent-enhanced spiral and electron-beam computed tomography (CT) for the analysis of segmental and subsegmental pulmonary arteries. MATERIALS AND METHODS: CT angiography of the pulmonary arteries was performed in 56 patients to rule out pulmonary embolism. Electron-beam CT was performed in 28 patients. The other 28 patients underwent spiral CT with comparable scanning protocols. The depiction of segmental and subsegmental arteries was analyzed by three independent readers. The contrast enhancement in the main pulmonary artery was measured in each patient. RESULTS: Analysis was performed in 1,120 segmental and 2,240 subsegmental arteries. One segmental (RA7, P = .010) and two subsegmental (LA7b, P = .029; RA6a+b, P = .038) arteries in paracardiac and basal segments of the lung were depicted significantly better with electron-beam CT. There was no statistically significant difference between electron-beam and spiral CT in the total number of analyzable peripheral arteries depicted. The mean contrast enhancement in the main pulmonary artery was 362 HU in electron-beam CT studies versus 248 HU in spiral CT Studies. CONCLUSION: Detailed visualization of peripheral pulmonary arteries is well within the scope of advanced CT techniques. Electron-beam CT has minor advantages in analyzing paracardiac arteries, probably because of reduction of motion artifacts and higher contrast enhancement. Further studies are needed to establish whether electron-beam CT allows a more confident diagnosis of emboli in these vessels.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [1] Detection of pulmonary emboli at the segmental and subsegmental level with electron-beam CT: Validation in a porcine model
    Goldin, JG
    Yoon, HC
    Greaser, LE
    Nishimura, EK
    [J]. ACADEMIC RADIOLOGY, 1998, 5 (07) : 503 - 508
  • [2] Diagnosis of pulmonary embolism with spiral and electron-beam CT
    Schoepf, UJ
    Brüning, RD
    Becker, CR
    Konschitzky, H
    Mühling, O
    Stäbler, A
    Knez, A
    Helmberger, T
    Holzknecht, N
    Haberl, R
    Reiser, MF
    [J]. RADIOLOGE, 1998, 38 (12): : 1036 - 1044
  • [3] Peripheral pulmonary arteries: Electron-beam versus helical CT scanning techniques
    Schoepf, UO
    Kang, D
    Helmberger, TK
    Holzknecht, NG
    Bruening, RD
    Reiser, MF
    [J]. RADIOLOGY, 1998, 209P : 495 - 495
  • [4] CT imaging of the abdomen: Electron-beam versus spiral and sequential scanning
    Schoepf, UO
    Bruening, RD
    Becker, CR
    Rogalla, P
    Georgi, M
    Reiser, MF
    [J]. RADIOLOGY, 1998, 209P : 409 - 409
  • [5] Spiral versus electron-beam CT for coronary artery calcium scoring
    Goldin, JG
    Yoon, HC
    Greaser, LE
    Heinze, SB
    McNitt-Gray, MM
    Brown, MS
    Sayre, JW
    Emerick, AM
    Aberle, DR
    [J]. RADIOLOGY, 2001, 221 (01) : 213 - 221
  • [6] Contrast enhanced spiral CT (CT) is comparable to pulmonary angiography for the diagnosis of segmental & subsegmental pulmonary emboli (PE).
    Baile, EM
    King, G
    Paré, PD
    D'yachkova, Y
    Müller, N
    Mayo, J
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A455 - A455
  • [7] Intravenous electron-beam CT based angiography: Segmental analysis of significant disease in the major coronary arteries
    Schmermund, A
    Rensing, BJ
    Sheedy, PF
    Bell, MR
    Rumberger, JA
    [J]. CIRCULATION, 1997, 96 (08) : 1705 - 1705
  • [8] Dose and image quality of electron-beam CT compared with spiral CT
    Weisser, G
    Lehmann, KJ
    Scheck, R
    Coppenrath, E
    Georgi, M
    [J]. INVESTIGATIVE RADIOLOGY, 1999, 34 (06) : 415 - 420
  • [9] CT pulmonary angiography: Normal segmental and subsegmental anatomy and variants
    Furukawa, A
    Lamb, TJ
    Khan, A
    Eacobacci, T
    Herman, PG
    [J]. RADIOLOGY, 1996, 201 : 378 - 378
  • [10] Preview method for electron-beam CT scanning of the coronary arteries
    Bakhsheshi, H
    Mao, SS
    Budoff, MJ
    Bin, L
    Brundage, BH
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (08) : 620 - 626