Dose and image quality of electron-beam CT compared with spiral CT

被引:13
|
作者
Weisser, G
Lehmann, KJ
Scheck, R
Coppenrath, E
Georgi, M
机构
[1] Univ Heidelberg, Klinikum Mannheim, Inst Klin Radiol, Fac Clin Med Mannheim,Dept Clin Radiol,Med Sch, D-68167 Mannheim, Germany
[2] Univ Munich, Klinikum Innenstadt, Inst Radiol Diagnost, D-8000 Munich, Germany
关键词
CT; electron beam; helical; radiation exposure;
D O I
10.1097/00004424-199906000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO examine dose and image quality of electron-beam CT (EBCT) with continuous volume scan versus spiral CT. METHODS. An EBCT scanner was compared with a spiral CT (SCT) scanner. Three phantoms were used to measure low-contrast resolution, high-contrast resolution, slice width, and dose. RESULTS. The EBCT scans showed 30% lower high-contrast resolution for most settings. The dose was comparable to that of spiral CT with 3 mm collimation and 76%/106% higher with EBCT for 1.5 mm/6 mm collimation. Low-contrast resolution was comparable to that of spiral CT using 3 mm collimation, slightly worse for 1.5 mm, and bad for 6 mm EBCT collimation (four times higher dose to reach comparable contrast-to-noise ratio). CONCLUSION. Significant restrictions were found using EBCT with continuous volume scan. The authors found that 3 mm collimation can yield acceptable high-contrast resolution and good low-contrast resolution compared with spiral CT. The use of 6 mm or 1.5 mm collimation needs to be restricted to selected cases.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 50 条
  • [1] Diagnosis of pulmonary embolism with spiral and electron-beam CT
    Schoepf, UJ
    Brüning, RD
    Becker, CR
    Konschitzky, H
    Mühling, O
    Stäbler, A
    Knez, A
    Helmberger, T
    Holzknecht, N
    Haberl, R
    Reiser, MF
    [J]. RADIOLOGE, 1998, 38 (12): : 1036 - 1044
  • [2] Radiation dose from electron-beam CT
    Schoepf, T
    Recheis, WA
    Knapp, R
    Bangerl, I
    ZurNedden, D
    [J]. RADIOLOGY, 1996, 201 : 1071 - 1071
  • [3] Effect of CT acquisition parameters of spiral CT on image quality and radiation dose
    Manmadhachary, A.
    Kumar, Y. Ravi
    Krishnanand, L.
    [J]. MEASUREMENT, 2017, 103 : 18 - 26
  • [4] CT imaging of the abdomen: Electron-beam versus spiral and sequential scanning
    Schoepf, UO
    Bruening, RD
    Becker, CR
    Rogalla, P
    Georgi, M
    Reiser, MF
    [J]. RADIOLOGY, 1998, 209P : 409 - 409
  • [5] Spiral versus electron-beam CT for coronary artery calcium scoring
    Goldin, JG
    Yoon, HC
    Greaser, LE
    Heinze, SB
    McNitt-Gray, MM
    Brown, MS
    Sayre, JW
    Emerick, AM
    Aberle, DR
    [J]. RADIOLOGY, 2001, 221 (01) : 213 - 221
  • [6] Electron-beam CT symposium
    Stanford, W
    [J]. ACADEMIC RADIOLOGY, 1999, 6 (02) : 83 - 83
  • [7] Head and neck effective dose and quantitative assessment of image quality: a study to compare cone beam CT and multislice spiral CT
    Nardi, Cosimo
    Talamonti, Cinzia
    Pallotta, Stefania
    Saletti, Paola
    Calistri, Linda
    Cordopatri, Cesare
    Colagrande, Stefano
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (07)
  • [8] Segmental and subsegmental pulmonary arteries: Evaluation with electron-beam versus spiral CT
    Schoepf, UJ
    Helmberger, T
    Holzknecht, N
    Kang, DS
    Bruening, RD
    Aydemir, S
    Becker, CR
    Muehling, O
    Knez, A
    Haberl, R
    Reiser, MF
    [J]. RADIOLOGY, 2000, 214 (02) : 433 - 439
  • [9] BREAST DOSE DURING ELECTRON-BEAM CT - MEASUREMENT WITH FILM DOSIMETRY
    MCCOLLOUGH, CH
    LIU, HH
    [J]. RADIOLOGY, 1995, 196 (01) : 153 - 157
  • [10] Chances and problems electron-beam CT
    Georgi, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 413 - 415