Rigid Motion Compensation in Interventional C-arm CT Using Consistency Measure on Projection Data

被引:19
|
作者
Frysch, Robert [1 ]
Rose, Georg [1 ]
机构
[1] Univ Magdeburg, Inst Med Engn, D-39106 Magdeburg, Germany
关键词
D O I
10.1007/978-3-319-24553-9_37
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Interventional C-arm CT has the potential to visualize brain hemorrhages in the operating suite and save valuable time for stroke patients. Due to the critical constitution of the patients, C-arm CT images are frequently affected by patient motion artifacts, which often makes the reliable diagnosis of hemorrhages impossible. In this work, we propose a geometric optimization algorithm to compensate for these artifacts and present first results. The algorithm is based on a projection data consistency measure, which avoids computationally expensive forward-and backprojection steps in the optimization process. The ability to estimate movements with this measure is investigated for different rigid degrees of freedom. It was shown that out-of-plane parameters, i.e. geometrical deviations perpendicular to the plane of rotation, can be estimated with high precision. Movement artifacts in reconstructions are consistently reduced throughout all analyzed clinical datasets. With its low computational cost and high robustness, the proposed algorithm is well-suited for integration into clinical software prototypes for further evaluation.
引用
收藏
页码:298 / 306
页数:9
相关论文
共 50 条
  • [21] Dynamic Iterative Reconstruction for Interventional 4-D C-Arm CT Perfusion Imaging
    Manhart, Michael T.
    Kowarschik, Markus
    Fieselmann, Andreas
    Deuerling-Zheng, Yu
    Royalty, Kevin
    Maier, Andreas K.
    Hornegger, Joachim
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (07) : 1336 - 1348
  • [22] Interventional Procedure under CT-fluoroscopy Combined with C-arm: Application in Lumbar Discography
    Kim, H.
    Lee, S.
    Chung, D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [23] Coping with real world data: Artifact reduction and denoising for motion-compensated cardiac C-arm CT
    Taubmann, Oliver
    Maier, Andreas
    Hornegger, Joachim
    Lauritsch, Guenter
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2016, 43 (02) : 883 - 893
  • [24] Range Imaging for Motion Compensation in C-Arm Cone-Beam CT of Knees under Weight-Bearing Conditions
    Bier, Bastian
    Ravikumar, Nishant
    Unberath, Mathias
    Levenston, Marc
    Gold, Garry
    Fahrig, Rebecca
    Maier, Andreas
    JOURNAL OF IMAGING, 2018, 4 (01)
  • [25] Current role of hybrid CT/angiography system compared with C-arm cone beam CT for interventional oncology
    Tanaka, T.
    Arai, Y.
    Inaba, Y.
    Inoue, M.
    Nishiofuku, H.
    Anai, H.
    Hori, S.
    Sakaguchi, H.
    Kichikawa, K.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041):
  • [26] A Novel Temporal Recovery Technique to Enable Cone Beam CT Perfusion Imaging Using an Interventional C-Arm System
    Tang, Jie
    Xu, Min
    Niu, Kai
    Royalty, Kevin
    Pulfer, Kari
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [27] System to Guide Transcatheter Aortic Valve Implantations Based on Interventional C-Arm CT Imaging
    John, Matthias
    Liao, Rui
    Zheng, Yefeng
    Noettling, Alois
    Boese, Jan
    Kirschstein, Uwe
    Kempfert, Joerg
    Walther, Thomas
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT I, 2010, 6361 : 375 - +
  • [28] Interventional 4-D C-Arm CT Perfusion Imaging Using Interleaved Scanning and Partial Reconstruction Interpolation
    Fieselmann, Andreas
    Ganguly, Arundhuti
    Yu Deuerling-Zheng
    Zellerhoff, Michael
    Rohkohl, Christopher
    Boese, Jan
    Hornegger, Joachim
    Fahrig, Rebecca
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (04) : 892 - 906
  • [29] Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data
    Grass, M
    Koppe, R
    Klotz, E
    Proksa, R
    Kuhn, MH
    Aerts, H
    Op de Beek, J
    Kemkers, R
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (06) : 311 - 321
  • [30] Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions
    Szczykutowicz, Timothy P.
    Labby, Zacariah E.
    Rubert, Nicholas
    Wallace, Charles
    MEDICAL PHYSICS, 2016, 43 (02) : 865 - 869