Rigid Motion Compensation in Interventional C-arm CT Using Consistency Measure on Projection Data

被引:19
|
作者
Frysch, Robert [1 ]
Rose, Georg [1 ]
机构
[1] Univ Magdeburg, Inst Med Engn, D-39106 Magdeburg, Germany
关键词
D O I
10.1007/978-3-319-24553-9_37
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Interventional C-arm CT has the potential to visualize brain hemorrhages in the operating suite and save valuable time for stroke patients. Due to the critical constitution of the patients, C-arm CT images are frequently affected by patient motion artifacts, which often makes the reliable diagnosis of hemorrhages impossible. In this work, we propose a geometric optimization algorithm to compensate for these artifacts and present first results. The algorithm is based on a projection data consistency measure, which avoids computationally expensive forward-and backprojection steps in the optimization process. The ability to estimate movements with this measure is investigated for different rigid degrees of freedom. It was shown that out-of-plane parameters, i.e. geometrical deviations perpendicular to the plane of rotation, can be estimated with high precision. Movement artifacts in reconstructions are consistently reduced throughout all analyzed clinical datasets. With its low computational cost and high robustness, the proposed algorithm is well-suited for integration into clinical software prototypes for further evaluation.
引用
收藏
页码:298 / 306
页数:9
相关论文
共 50 条
  • [31] Effect of hierarchical deformable motion compensation on image enhancement for DSA acquired via C-ARM
    Wei, Liyang
    Shen, Dinggang
    Kumar, Dinesh
    Turlapati, Ram
    Suri, Jasjit S.
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS VI, 2008, 6812
  • [32] Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP
    Pruemmer, M.
    Wigstroem, L.
    Hornegger, J.
    Boese, J.
    Lauritsch, G.
    Strobel, N.
    Fahrig, R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2620 - 2628
  • [33] Effect of respiratory motion on abdominal C-arm CT angiography using the 4D NCAT phantom
    Fung, G. S. K.
    Segars, W. P.
    Geschwind, J. -F. H.
    Tsui, B. M. W.
    Taguchi, K.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4536 - +
  • [34] Technical Feasibility of CT Perfusion using a C-Arm CBCT System
    Xu, Min
    Tang, Jie
    Royalty, Kevin
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [35] Truncation Correction for VOI C-arm CT using Scattered Radiation
    Bier, Bastian
    Maier, Andreas
    Hofmann, Hannes G.
    Schwemmer, Chris
    Xia, Yan
    Struffert, Tobias
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [36] Breathing motion compensated reconstruction for C-arm cone beam CT imaging: initial experience based on animal data
    Schaefer, D.
    Lin, M.
    Rao, P. P.
    Loffroy, R.
    Liapi, E.
    Noordhoek, N.
    Eshuis, P.
    Radaelli, A.
    Grass, M.
    Geschwind, J. -F. H.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [37] A Realistic Digital Phantom for Perfusion C-arm CT based on MRI Data
    Aichert, Andre
    Manhart, Michael T.
    Navalpakkam, Bharath K.
    Grimm, Robert
    Hutter, Jana
    Maier, Andreas
    Hornegger, Joachim
    Doerfler, Arnd
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [38] Comparing performance of many-core CPUs and GPUs for static and motion compensated reconstruction of C-arm CT data
    Hofmann, Hannes G.
    Keck, Benjamin
    Rohkohl, Christopher
    Hornegger, Joachim
    MEDICAL PHYSICS, 2011, 38 (01) : 468 - 473
  • [40] Image-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees
    Unberath, Mathias
    Choi, Jang-Hwan
    Berger, Martin
    Maier, Andreas
    Fahrig, Rebecca
    MEDICAL IMAGING 2015: IMAGE PROCESSING, 2015, 9413