Comparison of BioFire FilmArray gastrointestinal panel versus Luminex xTAG Gastrointestinal Pathogen Panel (xTAG GPP) for diarrheal pathogen detection in China

被引:16
|
作者
Zhan, Zhifei [1 ]
Guo, Jiayin [2 ]
Xiao, Yong [3 ]
He, Zixiang [1 ]
Xia, Xin [1 ]
Huang, Zheng [2 ]
Guan, Hongxia [3 ]
Ling, Xia [3 ]
Li, Jie [4 ]
Diao, Baowei [4 ]
Zhao, Hongqun [4 ]
Kan, Biao [4 ,5 ]
Zhang, Jingyun [4 ]
机构
[1] Hunan Prov Ctr Dis Control & Prevent, Changsha, Peoples R China
[2] Shanghai Changning Dist Ctr Dis Control & Prevent, Shanghai, Peoples R China
[3] Wuxi Ctr Dis Control & Prevent, Wuxi, Jiangsu, Peoples R China
[4] Chinese Ctr Dis Control & Prevent, Natl Inst Communicable Dis Control & Prevent, State Key Lab Infect Dis Prevent & Control, 155 Changbai Rd, Beijing 102206, Peoples R China
[5] Collaborat Innovat Ctr Diag & Treatment Infect Di, Hangzhou, Peoples R China
关键词
xTAG GPP; FilmArray GI; Diarrhea; Pathogen detection; Stool specimen; REAL-TIME PCR; CLOSTRIDIUM-DIFFICILE; ENTERIC PATHOGENS; ASSAY; GASTROENTERITIS; QUANTIFICATION; IDENTIFICATION; NOROVIRUS; DIAGNOSIS; TESTS;
D O I
10.1016/j.ijid.2020.08.020
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objectives: To compare the performance of two syndromic panels: Luminex xTAG Gastrointestinal Pathogen Panel (GPP) and FilmArray Gastrointestinal (GI) panel. Methods: A total of 243 diarrhea specimens were detected by two panels in parallel, and the inconsistent results were analyzed by real-time PCR or reverse transcription PCR (RT-PCR). The target concentration in specimens was examined by comparing the crossing point values of FilmArray, the median fluorescence intensity of xTAG and the cycle threshold values in any discrepancies. Results: For pathogens detected by both panels, the positive rates of FilmArray GI and xTAG GPP were 65.0% and 48.6%, respectively. The two panels showed high consistency (kappa >= 0.74) in detecting norovirus, rotavirus and Campylobacter, while there was low consistency (kappa <= 0.40) in detecting Cryptosporidium, Salmonella, Shiga toxin-producing Escherichia coli (STEC) and enterotoxigenic Escherichia coli (ETEC). Samples with low concentration targets were more often detected by FilmArray than with xTAG GPP. The xTAG GPP was more likely to be affected by amplification inhibitors. Several defects of xTAG GPP were found in detecting ETEC. Conclusions: FilmArray was more sensitive. For specimens with low target concentrations or containing ETEC heat stable enterotoxin, the false negatives of xTAG GPP need to be considered. (C) 2020 The Authors. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:414 / 420
页数:7
相关论文
共 50 条
  • [41] Evaluation of the BioFire Gastrointestinal Panel to Detect Diarrheal Pathogens in Pediatric Patients
    Jo, Sung Jin
    Kang, Hyun Mi
    Kim, Jung Ok
    Cho, Hanwool
    Heo, Woong
    Yoo, In Young
    Park, Yeon-Joon
    DIAGNOSTICS, 2022, 12 (01)
  • [42] Multicenter Evaluation of the BioFire FilmArray Gastrointestinal Panel for Etiologic Diagnosis of Infectious Gastroenteritis
    Buss, Sarah N.
    Leber, Amy
    Chapin, Kimberle
    Fey, Paul D.
    Bankowski, Matthew J.
    Jones, Matthew K.
    Rogatcheva, Margarita
    Kanack, Kristen J.
    Bourzac, Kevin M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (03) : 915 - 925
  • [43] Broad reactivity of the Luminex xTAG Respiratory Virus Panel (RVP) assay for the detection of human rhinoviruses
    Chandrasekaran, Alamelu
    Manji, Ryhana
    Joseph, Ansamma
    Zhang, Fan
    Ginocchio, Christine C.
    JOURNAL OF CLINICAL VIROLOGY, 2012, 53 (03) : 272 - 273
  • [44] Partial comparison of the NxTAG Respiratory Pathogen Panel Assay with the Luminex xTAG Respiratory Panel Fast Assay V2 and singleplex real-time polymerase chain reaction for detection of respiratory pathogens
    Esposito, Susanna
    Scala, Alessia
    Bianchini, Sonia
    Presicce, Maria Lory
    Mori, Alessandro
    Sciarrabba, Calogero Sathya
    Fior, Giulia
    Principi, Nicola
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2016, 86 (01) : 53 - 57
  • [45] Evaluation of the DiaSorin NxTAG gastrointestinal pathogen panel (GPP) and its integration into routine diagnostics
    Lugert, Raimond
    Laukat, Yvonne
    Rabenda, Sabine
    Weig, Michael
    Gross, Uwe
    Bohne, Wolfgang
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2025, 111 (03)
  • [46] Antibiotic use for diarrheal illness in patients with a positive molecular gastrointestinal pathogen panel result
    Eiffert, Samantha
    Ciccone, Emily
    Mackow, Natalie
    Kooken, Banks
    Miller, Melissa B.
    Kinlaw, Alan
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2022, 31 : 182 - 182
  • [47] Performance and Impact of the BioFire FilmArray Gastrointestinal Panel on a Large Cyclospora Outbreak in Wisconsin, 2018
    Bateman, Allen C.
    Kim, Youngmi J.
    Guaracao, Ana I.
    Mason, Jordan L.
    Klos, Rachel F.
    Warshauer, David M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (02)
  • [48] Application of Luminex Gastrointestinal Pathogen Panel to human stool samples from Cote d'Ivoire
    Di Cristanziano, Veronica
    Timmen-Wego, Monika
    Luebke, Nadine
    Kaiser, Rolf
    Pfister, Herbert
    Di Cave, David
    Berrilli, Federica
    Kabore, Yolande
    D'Alfonso, Rossella
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2015, 9 (08): : 884 - 889
  • [49] Evaluation of Luminex xTAG Gastrointestinal Pathogen Analyte-Specific Reagents for High-Throughput, Simultaneous Detection of Bacteria, Viruses, and Parasites of Clinical and Public Health Importance
    Navidad, Jose F.
    Griswold, David J.
    Gradus, M. Stephen
    Bhattacharyya, Sanjib
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (09) : 3018 - 3024
  • [50] Preliminary evaluation of BioFire FilmArray® Gastrointestinal Panel for the detection of noroviruses and other enteric viruses from wastewater and shellfish
    Pradip Gyawali
    Dawn Croucher
    Joanne Hewitt
    Environmental Science and Pollution Research, 2018, 25 : 27657 - 27661