Comparison of BioFire FilmArray gastrointestinal panel versus Luminex xTAG Gastrointestinal Pathogen Panel (xTAG GPP) for diarrheal pathogen detection in China

被引:16
|
作者
Zhan, Zhifei [1 ]
Guo, Jiayin [2 ]
Xiao, Yong [3 ]
He, Zixiang [1 ]
Xia, Xin [1 ]
Huang, Zheng [2 ]
Guan, Hongxia [3 ]
Ling, Xia [3 ]
Li, Jie [4 ]
Diao, Baowei [4 ]
Zhao, Hongqun [4 ]
Kan, Biao [4 ,5 ]
Zhang, Jingyun [4 ]
机构
[1] Hunan Prov Ctr Dis Control & Prevent, Changsha, Peoples R China
[2] Shanghai Changning Dist Ctr Dis Control & Prevent, Shanghai, Peoples R China
[3] Wuxi Ctr Dis Control & Prevent, Wuxi, Jiangsu, Peoples R China
[4] Chinese Ctr Dis Control & Prevent, Natl Inst Communicable Dis Control & Prevent, State Key Lab Infect Dis Prevent & Control, 155 Changbai Rd, Beijing 102206, Peoples R China
[5] Collaborat Innovat Ctr Diag & Treatment Infect Di, Hangzhou, Peoples R China
关键词
xTAG GPP; FilmArray GI; Diarrhea; Pathogen detection; Stool specimen; REAL-TIME PCR; CLOSTRIDIUM-DIFFICILE; ENTERIC PATHOGENS; ASSAY; GASTROENTERITIS; QUANTIFICATION; IDENTIFICATION; NOROVIRUS; DIAGNOSIS; TESTS;
D O I
10.1016/j.ijid.2020.08.020
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objectives: To compare the performance of two syndromic panels: Luminex xTAG Gastrointestinal Pathogen Panel (GPP) and FilmArray Gastrointestinal (GI) panel. Methods: A total of 243 diarrhea specimens were detected by two panels in parallel, and the inconsistent results were analyzed by real-time PCR or reverse transcription PCR (RT-PCR). The target concentration in specimens was examined by comparing the crossing point values of FilmArray, the median fluorescence intensity of xTAG and the cycle threshold values in any discrepancies. Results: For pathogens detected by both panels, the positive rates of FilmArray GI and xTAG GPP were 65.0% and 48.6%, respectively. The two panels showed high consistency (kappa >= 0.74) in detecting norovirus, rotavirus and Campylobacter, while there was low consistency (kappa <= 0.40) in detecting Cryptosporidium, Salmonella, Shiga toxin-producing Escherichia coli (STEC) and enterotoxigenic Escherichia coli (ETEC). Samples with low concentration targets were more often detected by FilmArray than with xTAG GPP. The xTAG GPP was more likely to be affected by amplification inhibitors. Several defects of xTAG GPP were found in detecting ETEC. Conclusions: FilmArray was more sensitive. For specimens with low target concentrations or containing ETEC heat stable enterotoxin, the false negatives of xTAG GPP need to be considered. (C) 2020 The Authors. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:414 / 420
页数:7
相关论文
共 50 条
  • [31] Diagnostic performance of the Luminex xTAG gastrointestinal pathogens panel to detect rotavirus in Ghanaian children with and without diarrhoea
    Leva, Amelie
    Eibach, Daniel
    Krumkamp, Ralf
    Kaesmaier, Julia
    Rubbenstroth, Dennis
    Adu-Sarkodie, Yaw
    May, Juergen
    Tannich, Egbert
    Panning, Marcus
    VIROLOGY JOURNAL, 2016, 13
  • [32] Diagnostic performance of the Luminex xTAG gastrointestinal pathogens panel to detect rotavirus in Ghanaian children with and without diarrhoea
    Amelie Leva
    Daniel Eibach
    Ralf Krumkamp
    Julia Käsmaier
    Dennis Rubbenstroth
    Yaw Adu-Sarkodie
    Jürgen May
    Egbert Tannich
    Marcus Panning
    Virology Journal, 13
  • [33] The limit of detection of the BioFire® FilmArray® gastrointestinal panel for the foodborne parasite Cyclospora cayetanensis
    Peterson, Anna
    Richins, Travis
    Houghton, Katelyn
    Mishina, Margarita
    Sharma, Suresh
    Sambhara, Suryaprakash
    Jacobson, David
    Qvarnstrom, Yvonne
    Cama, Vitaliano
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2023, 107 (02)
  • [34] Clinical Performance of xTAG® GPP Multiplexed Gastrointestinal Panel for the Simultaneous Detection and Identification of Viral Bacterial and Parasitic Pathogens in Stool Specimens
    Yaghoubian, S.
    Himsworth, D.
    Dey, C.
    Lan, L.
    Bussel, M. V.
    Claas, E. C.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2010, 12 (06): : 881 - 881
  • [35] Impact of the BioFire FilmArray gastrointestinal panel on patient care and infection control
    Machiels, Julian D.
    Cremers, Amelieke J. H.
    van Bergen-Verkuyten, Muriel C. G. T.
    Paardekoper-Strijbosch, Sandra J. M.
    Frijns, Kelly C. J.
    Wertheim, Heiman F. L.
    Rahamat-Langendoen, Janette
    Melchers, Willem J. G.
    PLOS ONE, 2020, 15 (02):
  • [36] Comparison of Respiratory Pathogen Detection in Upper versus Lower Respiratory Tract Samples Using the BioFire FilmArray Respiratory Panel in the Immunocompromised Host
    Azadeh, Natalya
    Sakata, Kenneth K.
    Saeed, Ali
    Mullon, John J.
    Grys, Thomas E.
    Limper, Andrew H.
    Binnicker, Matthew J.
    CANADIAN RESPIRATORY JOURNAL, 2018, 2018
  • [37] Verification of the BioFire FilmArray Pneumonia Plus Panel for pathogen screening of respiratory specimens
    Sparks, Rebecca
    Balgahom, Rifky
    Janto, Catherine
    Polkinghorne, Adam
    Branley, James
    PATHOLOGY, 2021, 53 (07) : 919 - 922
  • [38] The Impact of a Positive Biofire® FilmArray® Gastrointestinal Panel Result on Clinical Management and Outcomes
    Carmon, David
    Rohana, Hanan
    Azrad, Maya
    Peretz, Avi
    DIAGNOSTICS, 2023, 13 (06)
  • [39] Comparative Evaluation of Luminex xTAG® Gastrointestinal Pathogen Panel and Direct-From-Stool Real-Time PCR for Detection of C. difficile Toxin tcdB in Stool Samples from a Pediatric Population
    Tyrrell, Hannah
    Morin, Sarah B. N.
    Lloyd, Colin D.
    Parsons, Brendon
    Stokowski, Taryn
    Xie, Jianling
    Zhuo, Ran
    Lee, Bonita E.
    Pang, Xiao-Li
    Freedman, Stephen B.
    Chui, Linda
    MICROORGANISMS, 2022, 10 (11)
  • [40] Clinical and Histologic Features of Patients Tested Using the BioFire FilmArray Gastrointestinal Panel
    Mowers, J. C.
    Chain, K.
    Bachman, M.
    Greenson, J.
    Lamps, L. W.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2019, 21 (06): : 1158 - 1158