Comparison of BioFire FilmArray gastrointestinal panel versus Luminex xTAG Gastrointestinal Pathogen Panel (xTAG GPP) for diarrheal pathogen detection in China

被引:16
|
作者
Zhan, Zhifei [1 ]
Guo, Jiayin [2 ]
Xiao, Yong [3 ]
He, Zixiang [1 ]
Xia, Xin [1 ]
Huang, Zheng [2 ]
Guan, Hongxia [3 ]
Ling, Xia [3 ]
Li, Jie [4 ]
Diao, Baowei [4 ]
Zhao, Hongqun [4 ]
Kan, Biao [4 ,5 ]
Zhang, Jingyun [4 ]
机构
[1] Hunan Prov Ctr Dis Control & Prevent, Changsha, Peoples R China
[2] Shanghai Changning Dist Ctr Dis Control & Prevent, Shanghai, Peoples R China
[3] Wuxi Ctr Dis Control & Prevent, Wuxi, Jiangsu, Peoples R China
[4] Chinese Ctr Dis Control & Prevent, Natl Inst Communicable Dis Control & Prevent, State Key Lab Infect Dis Prevent & Control, 155 Changbai Rd, Beijing 102206, Peoples R China
[5] Collaborat Innovat Ctr Diag & Treatment Infect Di, Hangzhou, Peoples R China
关键词
xTAG GPP; FilmArray GI; Diarrhea; Pathogen detection; Stool specimen; REAL-TIME PCR; CLOSTRIDIUM-DIFFICILE; ENTERIC PATHOGENS; ASSAY; GASTROENTERITIS; QUANTIFICATION; IDENTIFICATION; NOROVIRUS; DIAGNOSIS; TESTS;
D O I
10.1016/j.ijid.2020.08.020
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objectives: To compare the performance of two syndromic panels: Luminex xTAG Gastrointestinal Pathogen Panel (GPP) and FilmArray Gastrointestinal (GI) panel. Methods: A total of 243 diarrhea specimens were detected by two panels in parallel, and the inconsistent results were analyzed by real-time PCR or reverse transcription PCR (RT-PCR). The target concentration in specimens was examined by comparing the crossing point values of FilmArray, the median fluorescence intensity of xTAG and the cycle threshold values in any discrepancies. Results: For pathogens detected by both panels, the positive rates of FilmArray GI and xTAG GPP were 65.0% and 48.6%, respectively. The two panels showed high consistency (kappa >= 0.74) in detecting norovirus, rotavirus and Campylobacter, while there was low consistency (kappa <= 0.40) in detecting Cryptosporidium, Salmonella, Shiga toxin-producing Escherichia coli (STEC) and enterotoxigenic Escherichia coli (ETEC). Samples with low concentration targets were more often detected by FilmArray than with xTAG GPP. The xTAG GPP was more likely to be affected by amplification inhibitors. Several defects of xTAG GPP were found in detecting ETEC. Conclusions: FilmArray was more sensitive. For specimens with low target concentrations or containing ETEC heat stable enterotoxin, the false negatives of xTAG GPP need to be considered. (C) 2020 The Authors. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:414 / 420
页数:7
相关论文
共 50 条
  • [21] Comparison of Luminex NxTAG Respiratory Pathogen Panel and xTAG Respiratory Viral Panel FAST Version 2 for the Detection of Respiratory Viruses
    Lee, Chun Kiat
    Lee, Hong Kai
    Ng, Christopher Wei Siong
    Chiu, Lily
    Tang, Julian Wei-Tze
    Tze Ping Loh
    Koay, Evelyn Siew-Chuan
    ANNALS OF LABORATORY MEDICINE, 2017, 37 (03) : 267 - 271
  • [22] Detection of Norovirus by BD MAX™, Xpert® Norovirus, and xTAG® Gastrointestinal Pathogen Panel in stool and vomit samples
    McHugh, Martin P.
    Guerendiain, Daniel
    Hardie, Alison
    Kenicer, Juliet
    MacKenzie, Laura
    Templeton, Kate E.
    JOURNAL OF CLINICAL VIROLOGY, 2018, 105 : 72 - 76
  • [23] Comparison of the Biofire FilmArray RP, Genmark eSensor RVP, Luminex xTAG RVPv1, and Luminex xTAG RVP Fast Multiplex Assays for Detection of Respiratory Viruses
    Popowitch, Elena B.
    O'Neill, Stacey S.
    Miller, Melissa B.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (05) : 1528 - 1533
  • [24] Comparison of the Luminex xTAG Respiratory Viral Panel with xTAG Respiratory Viral Panel Fast for Diagnosis of Respiratory Virus Infections
    Pabbaraju, Kanti
    Wong, Sallene
    Tokaryk, Kara L.
    Fonseca, Kevin
    Drews, Steven J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (05) : 1738 - 1744
  • [25] Characterization of GenMark ePlex Respiratory Pathogen Panel and Comparison to BioFire FilmArray RP Panel
    Schroeder, A. R.
    Osato, D.
    Henthorn, K.
    Moberly, J.
    Wong, K.
    Mohamed, N.
    Hoeft, C.
    Vansickle, R.
    Safavi, A.
    Borillo, G.
    Kulkarni, S.
    Le, P.
    Freeman-Cook, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2016, 18 (06): : 984 - 985
  • [26] Comparative Performance of the Luminex NxTAG Respiratory Pathogen Panel, GenMark eSensor Respiratory Viral Panel, and BioFire FilmArray Respiratory Panel
    Popowitch, Elena B.
    Kaplan, Sam
    Wu, Zenglin
    Tang, Yi-Wei
    Miller, Melissa B.
    MICROBIOLOGY SPECTRUM, 2022, 10 (04):
  • [27] Performance of the xTAG® Gastrointestinal Pathogen Panel, a Multiplex Molecular Assay for Simultaneous Detection of Bacterial, Viral, and Parasitic Causes of Infectious Gastroenteritis
    Claas, Eric C.
    Burnham, Carey-Ann D.
    Mazzulli, Tony
    Templeton, Kate
    Topin, Francois
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2013, 23 (07) : 1041 - 1045
  • [28] Clinical and Histologic Correlates of the FilmArray BioFire Gastrointestinal Panel
    Mowers, Jonathan
    Lamps, Laura W.
    Greenson, Joel
    Bachman, Michael
    LABORATORY INVESTIGATION, 2018, 98 : 290 - 290
  • [29] Clinical and Histologic Correlates of the FilmArray BioFire Gastrointestinal Panel
    Mowers, Jonathan
    Lamps, Laura W.
    Greenson, Joel
    Bachman, Michael
    MODERN PATHOLOGY, 2018, 31 : 290 - 290
  • [30] Comparison of xTAG RVP Fast Assay (Luminex) to the eSensor RVP (GenMark Dx) and FilmArray RP (BioFire)
    Ratner, C.
    Saxena, S. S.
    Henry, R.
    Naeem, R. C.
    Fox, A. S.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2015, 17 (06): : 795 - 795