Imaging Performance for Two Row-Column Arrays

被引:30
|
作者
Bouzari, Hamed [1 ,2 ]
Engholm, Mathias [3 ]
Nikolov, Svetoslav Ivanov [4 ]
Stuart, Matthias Bo [1 ]
Thomsen, Erik Vilain [3 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] Fingerprint Cards AB, DK-2730 Herlev, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] BK Med, DK-2730 Herlev, Denmark
关键词
3-D imaging; beamforming; row-column arrays; volumetric ultrasound imaging; CYSTIC RESOLUTION; SAFETY ASSESSMENT; ADDRESSED ARRAYS; CMUT ARRAYS; 2-D ARRAY; TRANSDUCER; DESIGN; SYSTEM;
D O I
10.1109/TUFFC.2019.2914348
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study evaluates the volumetric imaging performance of two prototyped 62 + 62 row-column-addressed (RCA) 2-D array transducer probes using three synthetic aperture imaging (SAI) emission sequences and two different beamformers. The probes are fabricated using capacitive micromachined ultrasonic transducer (CMUT) and piezoelectric transducer (PZT) technology. Both have integrated apodization to reduce ghost echoes and are designed with similar acoustical features, i.e., 3-MHz center frequency, lambda/2 pitch, and 24.8 x 24.8 mm(2) active footprint. Raw RF data are obtained using an experimental research ultrasound scanner, SARUS. The SAI sequences are designed for imaging down to 14 cm at a volume rate of 88 Hz. Two beamforming methods, spatial matched filtering and row-column adapted delay-and-sum, are used for beamforming the RF data. The imaging quality is investigated through simulations and phantom measurements. Both probes on average have similar lateral full-width at half-maximum (FWHM) values, but the PZT probe has 20% smaller cystic resolution values and 70% larger contrast-to-noise ratio (CNR) compared to the capacitive micromachined ultrasonic transducer (CMUT) probe. The CMUT probe can penetrate down to 15 cm, and the PZT probe down to 30 cm. The CMUT probe has 17% smaller axial FWHM values. The matched filter focusing shows an improved B-mode image for measurements on a cyst phantom with an improved speckle pattern and better visualization of deeper lying cysts. The results of this study demonstrate the potentials of RCA 2-D arrays against fully addressed 2-D arrays, which are low channel count (e.g., 124 instead of 3844), low acoustic intensity mechanical index (MI <= 0.88 and spatial-peak-temporal-average intensity I-spta <= 5.5 mW/cm(2)), and high penetration depth (down to 30 cm), which makes 3-D imaging at high volume rates possible with equipment in the price range of conventional 2-D imaging.
引用
收藏
页码:1209 / 1221
页数:13
相关论文
共 50 条
  • [1] Conformable Row-Column Ultrasound Arrays for Abdominal Imaging
    Lu, Jian-yu
    Jiang, Xiaoning
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1753 - 1756
  • [2] Anatomic and Functional Imaging Using Row-Column Arrays
    Jensen, Jorgen Arendt
    Schou, Mikkel
    Jorgensen, Lasse Thurmann
    Tomov, Borislav G.
    Stuart, Matthias Bo
    Traberg, Marie Sand
    Taghavi, Iman
    Oygaard, Sigrid Huesebo
    Ommen, Martin Lind
    Steenberg, Kitty
    Thomsen, Erik Vilain
    Panduro, Nathalie Sarup
    Nielsen, Michael Bachmann
    Sorensen, Charlotte Mehlin
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (10) : 2722 - 2738
  • [3] Row-Column Addressed Arrays for Nondestructive Evaluation Applications
    Kirkpatrick, James P.
    Wilcox, Paul D.
    Smith, Robert A.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (06) : 1119 - 1128
  • [4] ROW-COLUMN DISCRETE PHASING OF ANTENNA-ARRAYS
    ANTIPIN, AG
    ANTOSHKOVA, IM
    PUZANKOV, AF
    [J]. TELECOMMUNICATIONS AND RADIO ENGINEERING, 1986, 40-1 (12) : 117 - 119
  • [5] Row-Column Beamformer for Fast Volumetric Imaging
    Jorgensen, Lasse Thurmann
    Proesius, Sebastian Kazmarek
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (07) : 668 - 680
  • [6] ROW-COLUMN BEAMFORMER FOR FAST VOLUMETRIC IMAGING
    Jorgensen, Lasse Thurmann
    Praesius, Sebastian Kazmarek
    Panduro, Nathalie Sarup
    Andersen, Sofie Bech
    Sorensen, Charlotte Mehlin
    Jensen, Jorgen Arendt
    [J]. 2023 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING WORKSHOPS, ICASSPW, 2023,
  • [7] Optimal row-column design for two treatments
    Morgan, JP
    Uddin, N
    [J]. JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 2003, 115 (02) : 603 - 622
  • [8] Wafer Level Characterization of Row-Column Addressed CMUT Arrays
    Thomsen, Erik. V.
    Steenberg, Kitty
    Petersen, Magnus G.
    Weile, Mads
    Havreland, Andreas
    Ommen, Martin L.
    Grass, Rune S.
    Engholm, Mathias
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 770 - 773
  • [9] ROBUSTNESS OF ROW-COLUMN DESIGNS
    SINGH, G
    GUPTA, S
    SINGH, M
    [J]. STATISTICS & PROBABILITY LETTERS, 1987, 5 (06) : 421 - 424
  • [10] Optimal row-column designs
    Zhou, Zheng
    Zhou, Yongdao
    [J]. BIOMETRIKA, 2023, 110 (02) : 537 - 549