Anatomic and Functional Imaging Using Row-Column Arrays

被引:19
|
作者
Jensen, Jorgen Arendt [1 ]
Schou, Mikkel [1 ]
Jorgensen, Lasse Thurmann [1 ]
Tomov, Borislav G. [1 ]
Stuart, Matthias Bo [1 ]
Traberg, Marie Sand [1 ]
Taghavi, Iman [1 ]
Oygaard, Sigrid Huesebo [2 ]
Ommen, Martin Lind [3 ]
Steenberg, Kitty [3 ]
Thomsen, Erik Vilain [3 ]
Panduro, Nathalie Sarup [4 ]
Nielsen, Michael Bachmann [5 ]
Sorensen, Charlotte Mehlin [4 ]
机构
[1] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] Dolphitech, N-2815 Gjovik, Norway
[3] Tech Univ Denmark, Dept Hlth Technol, MEMS Grp, DK-2800 Lyngby, Denmark
[4] Univ Copenhagen, Dept Biomed Sci, DK-2100 Copenhagen, Denmark
[5] Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
基金
欧洲研究理事会;
关键词
Beam forming; row-column (RC) arrays; super resolution; ultrasound; velocity measurement; ADDRESSED 2-D ARRAYS; ACOUSTIC SUPERRESOLUTION; MOTION-CORRECTION; CMUT ARRAYS; ULTRASOUND; VELOCITY; TRANSDUCER; DESIGN; SYSTEM;
D O I
10.1109/TUFFC.2022.3191391
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator's workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below 20 mu m. RC arrays can, thus, yield full 3-0 imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.
引用
收藏
页码:2722 / 2738
页数:17
相关论文
共 50 条
  • [1] Imaging Performance for Two Row-Column Arrays
    Bouzari, Hamed
    Engholm, Mathias
    Nikolov, Svetoslav Ivanov
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (07) : 1209 - 1221
  • [2] Conformable Row-Column Ultrasound Arrays for Abdominal Imaging
    Lu, Jian-yu
    Jiang, Xiaoning
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1753 - 1756
  • [3] Row-Column Addressed Arrays for Nondestructive Evaluation Applications
    Kirkpatrick, James P.
    Wilcox, Paul D.
    Smith, Robert A.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (06) : 1119 - 1128
  • [4] ROW-COLUMN DISCRETE PHASING OF ANTENNA-ARRAYS
    ANTIPIN, AG
    ANTOSHKOVA, IM
    PUZANKOV, AF
    [J]. TELECOMMUNICATIONS AND RADIO ENGINEERING, 1986, 40-1 (12) : 117 - 119
  • [5] Row-Column Beamformer for Fast Volumetric Imaging
    Jorgensen, Lasse Thurmann
    Proesius, Sebastian Kazmarek
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (07) : 668 - 680
  • [6] ROW-COLUMN BEAMFORMER FOR FAST VOLUMETRIC IMAGING
    Jorgensen, Lasse Thurmann
    Praesius, Sebastian Kazmarek
    Panduro, Nathalie Sarup
    Andersen, Sofie Bech
    Sorensen, Charlotte Mehlin
    Jensen, Jorgen Arendt
    [J]. 2023 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING WORKSHOPS, ICASSPW, 2023,
  • [7] High-Voltage Bias-Switching Electronics for Volumetric Imaging Using Electrostrictive Row-Column Arrays
    Ilkhechi, Afshin Kashani
    Palamar, Randy
    Sobhani, Mohammad Rahim
    Dahunsi, Darren
    Ceroici, Christopher
    Ghavami, Mahyar
    Brown, Jeremy
    Zemp, Roger
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (04) : 324 - 335
  • [8] 4D Functional Imaging of the Rat Brain Using a Large Aperture Row-Column Array
    Sauvage, Jack
    Poree, Jonathan
    Rabut, Claire
    Ferin, Guillaume
    Flesch, Martin
    Rosinski, Bogdan
    An Nguyen-Dinh
    Tanter, Mickael
    Pernot, Mathieu
    Deffieux, Thomas
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 1884 - 1893
  • [9] Wafer Level Characterization of Row-Column Addressed CMUT Arrays
    Thomsen, Erik. V.
    Steenberg, Kitty
    Petersen, Magnus G.
    Weile, Mads
    Havreland, Andreas
    Ommen, Martin L.
    Grass, Rune S.
    Engholm, Mathias
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 770 - 773
  • [10] Volumetric Ultrasound Imaging with Row-Column Addressed 2-D Arrays Using Spatial Matched Filter Beamforming
    Bouzari, Hamed
    Engholm, Mathias
    Christiansen, Thomas Lehrmann
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,