Imaging Performance for Two Row-Column Arrays

被引:30
|
作者
Bouzari, Hamed [1 ,2 ]
Engholm, Mathias [3 ]
Nikolov, Svetoslav Ivanov [4 ]
Stuart, Matthias Bo [1 ]
Thomsen, Erik Vilain [3 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] Fingerprint Cards AB, DK-2730 Herlev, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] BK Med, DK-2730 Herlev, Denmark
关键词
3-D imaging; beamforming; row-column arrays; volumetric ultrasound imaging; CYSTIC RESOLUTION; SAFETY ASSESSMENT; ADDRESSED ARRAYS; CMUT ARRAYS; 2-D ARRAY; TRANSDUCER; DESIGN; SYSTEM;
D O I
10.1109/TUFFC.2019.2914348
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study evaluates the volumetric imaging performance of two prototyped 62 + 62 row-column-addressed (RCA) 2-D array transducer probes using three synthetic aperture imaging (SAI) emission sequences and two different beamformers. The probes are fabricated using capacitive micromachined ultrasonic transducer (CMUT) and piezoelectric transducer (PZT) technology. Both have integrated apodization to reduce ghost echoes and are designed with similar acoustical features, i.e., 3-MHz center frequency, lambda/2 pitch, and 24.8 x 24.8 mm(2) active footprint. Raw RF data are obtained using an experimental research ultrasound scanner, SARUS. The SAI sequences are designed for imaging down to 14 cm at a volume rate of 88 Hz. Two beamforming methods, spatial matched filtering and row-column adapted delay-and-sum, are used for beamforming the RF data. The imaging quality is investigated through simulations and phantom measurements. Both probes on average have similar lateral full-width at half-maximum (FWHM) values, but the PZT probe has 20% smaller cystic resolution values and 70% larger contrast-to-noise ratio (CNR) compared to the capacitive micromachined ultrasonic transducer (CMUT) probe. The CMUT probe can penetrate down to 15 cm, and the PZT probe down to 30 cm. The CMUT probe has 17% smaller axial FWHM values. The matched filter focusing shows an improved B-mode image for measurements on a cyst phantom with an improved speckle pattern and better visualization of deeper lying cysts. The results of this study demonstrate the potentials of RCA 2-D arrays against fully addressed 2-D arrays, which are low channel count (e.g., 124 instead of 3844), low acoustic intensity mechanical index (MI <= 0.88 and spatial-peak-temporal-average intensity I-spta <= 5.5 mW/cm(2)), and high penetration depth (down to 30 cm), which makes 3-D imaging at high volume rates possible with equipment in the price range of conventional 2-D imaging.
引用
收藏
页码:1209 / 1221
页数:13
相关论文
共 50 条
  • [41] Construction of row-column factorial designs
    Godolphin, J. D.
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 2019, 81 (02) : 335 - 360
  • [42] SOME AUGMENTED ROW-COLUMN DESIGNS
    FEDERER, WT
    NAIR, RC
    RAGHAVARAO, D
    [J]. BIOMETRICS, 1975, 31 (02) : 361 - 373
  • [43] ROW-COLUMN DESIGNS WITH VARYING REPLICATIONS
    Kumari, S.
    Mehta, B. D.
    Saxena, K. K.
    [J]. STATISTICA, 2006, 66 (01): : 51 - 57
  • [44] Row-column visibility graph approach to two-dimensional landscapes
    Xiao Qin
    Pan Xue
    Li Xin-Li
    Stephen, Mutua
    Yang Hui-Jie
    Jiang Yan
    Wang Jian-Yong
    Zhang Qing-Jun
    [J]. CHINESE PHYSICS B, 2014, 23 (07)
  • [45] Volumetric Ultrasound Imaging with Row-Column Addressed 2-D Arrays Using Spatial Matched Filter Beamforming
    Bouzari, Hamed
    Engholm, Mathias
    Christiansen, Thomas Lehrmann
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [46] Experimental 3-D Vector Velocity Estimation with Row-Column Addressed Arrays
    Holbek, Simon
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [47] A Row-Column Summing Readout Architecture for SiPM based PET Imaging Systems
    Dey, Samrat
    Myers, Edward
    Lewellen, Thomas K.
    Miyaoka, Robert S.
    Rudell, Jacques C.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [48] SOME OPTIMAL NESTED ROW-COLUMN DESIGNS
    CHANG, JY
    NOTZ, WI
    [J]. STATISTICA SINICA, 1994, 4 (01) : 249 - 263
  • [49] METHOD FOR COMBINED ROW-COLUMN REDUCTION OF FLOWTABLES
    GRASSELL.A
    LUCCIO, F
    [J]. AUTOMATION AND REMOTE CONTROL, 1968, (08) : 1283 - &
  • [50] CONNECTEDNESS AND OPTIMALITY OF A CLASS OF ROW-COLUMN DESIGNS
    RUSSELL, KG
    [J]. COMMUNICATIONS IN STATISTICS PART A-THEORY AND METHODS, 1976, A 5 (15): : 1479 - 1488