Imaging Performance for Two Row-Column Arrays

被引:30
|
作者
Bouzari, Hamed [1 ,2 ]
Engholm, Mathias [3 ]
Nikolov, Svetoslav Ivanov [4 ]
Stuart, Matthias Bo [1 ]
Thomsen, Erik Vilain [3 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] Fingerprint Cards AB, DK-2730 Herlev, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] BK Med, DK-2730 Herlev, Denmark
关键词
3-D imaging; beamforming; row-column arrays; volumetric ultrasound imaging; CYSTIC RESOLUTION; SAFETY ASSESSMENT; ADDRESSED ARRAYS; CMUT ARRAYS; 2-D ARRAY; TRANSDUCER; DESIGN; SYSTEM;
D O I
10.1109/TUFFC.2019.2914348
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study evaluates the volumetric imaging performance of two prototyped 62 + 62 row-column-addressed (RCA) 2-D array transducer probes using three synthetic aperture imaging (SAI) emission sequences and two different beamformers. The probes are fabricated using capacitive micromachined ultrasonic transducer (CMUT) and piezoelectric transducer (PZT) technology. Both have integrated apodization to reduce ghost echoes and are designed with similar acoustical features, i.e., 3-MHz center frequency, lambda/2 pitch, and 24.8 x 24.8 mm(2) active footprint. Raw RF data are obtained using an experimental research ultrasound scanner, SARUS. The SAI sequences are designed for imaging down to 14 cm at a volume rate of 88 Hz. Two beamforming methods, spatial matched filtering and row-column adapted delay-and-sum, are used for beamforming the RF data. The imaging quality is investigated through simulations and phantom measurements. Both probes on average have similar lateral full-width at half-maximum (FWHM) values, but the PZT probe has 20% smaller cystic resolution values and 70% larger contrast-to-noise ratio (CNR) compared to the capacitive micromachined ultrasonic transducer (CMUT) probe. The CMUT probe can penetrate down to 15 cm, and the PZT probe down to 30 cm. The CMUT probe has 17% smaller axial FWHM values. The matched filter focusing shows an improved B-mode image for measurements on a cyst phantom with an improved speckle pattern and better visualization of deeper lying cysts. The results of this study demonstrate the potentials of RCA 2-D arrays against fully addressed 2-D arrays, which are low channel count (e.g., 124 instead of 3844), low acoustic intensity mechanical index (MI <= 0.88 and spatial-peak-temporal-average intensity I-spta <= 5.5 mW/cm(2)), and high penetration depth (down to 30 cm), which makes 3-D imaging at high volume rates possible with equipment in the price range of conventional 2-D imaging.
引用
收藏
页码:1209 / 1221
页数:13
相关论文
共 50 条
  • [31] ROW-COLUMN ALPHA-DESIGNS
    JOHN, JA
    ECCLESTON, JA
    [J]. BIOMETRIKA, 1986, 73 (02) : 301 - 306
  • [32] THE ROW-COLUMN PIVOTING STRATEGY ON MULTICOMPUTERS
    ANGELACCIO, M
    COLAJANNI, M
    [J]. PARALLEL COMPUTING, 1994, 20 (02) : 197 - 213
  • [33] Structurally incomplete row-column designs
    Parsad, R
    Gupta, VK
    Prasad, NSG
    [J]. COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2003, 32 (01) : 239 - 261
  • [34] Row-column response surface designs
    Gilmour, SG
    Trinca, LA
    [J]. JOURNAL OF QUALITY TECHNOLOGY, 2003, 35 (02) : 184 - 193
  • [35] A class of saturated row-column designs
    Qu, Xianggui
    Ogunyemi, Theophilus
    Kushler, Robert
    [J]. JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 2010, 140 (03) : 781 - 790
  • [36] A novel Row-Column Addressed stack architecture for enhanced cardiac imaging
    Ferin, Guillaume
    Dumoux, Marie-Coline
    Flesch, Martin
    Montauban, Emmanuel
    Lejeune, Agnes
    Rosinski, Bogdan
    Mateo, Tony
    Poree, Jonathan
    Sauvage, Jack
    Deffieux, Thomas
    Pemot, Mathieu
    Tanter, Mickael
    An Nguyen-Dinh
    [J]. 2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [37] Row-column designs with minimal units
    Qu, Xianggui
    [J]. JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 2011, 141 (09) : 3193 - 3200
  • [38] Generalized confounded row-column designs
    Datta, Anindita
    Jaggi, Seema
    Varghese, Eldho
    Varghese, Cini
    [J]. COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2017, 46 (12) : 6213 - 6221
  • [39] Validating a model of row-column scanning
    Mankowski, Robert
    Simpson, Richard C.
    Koester, Heidi H.
    [J]. DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2013, 8 (04) : 321 - 329
  • [40] A class of saturated row-column designs
    Kashinath Chatterjee
    Aloke Dey
    [J]. Indian Journal of Pure and Applied Mathematics, 2010, 41 : 293 - 302