On the correlation between crystal morphology and X-ray performance of a CdZnTe detector

被引:2
|
作者
Bavdaz, M
Peacock, A
Nenonen, S
Jantunen, MA
Gagliardi, T
Tuomi, T
Hjelt, KT
Juvonen, M
Rantamaki, R
Kraft, S
Wedowski, M
Scholze, F
Ulm, G
McNally, PJ
Curley, J
Danilewsky, AN
机构
关键词
X-ray detectors; CdZnTe; X-ray astronomy; compound semiconductors;
D O I
10.1117/12.278895
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Using a CdZnTe sample detector, a variety of diagnostic tools are applied, so as to assess the crystal characteristics and to compare these to the X-ray response measured with synchrotron radiation. Correlations are found, such that X-ray response degrading processes can be identified. In this respect the performance of the detector is found to be limited by both large scale defects such as some grain boundaries and also pipes and by crystal imperfections, together with impurities and other crystal defects, both at the surface and in the bulk crystal. The relatively soft CdZnTe crystals are very sensitive to improper handling, producing particularly surface damage, which in turn deteriorates the detector performance, as is rather clearly established by photoluminescence measurements.
引用
收藏
页码:322 / 332
页数:11
相关论文
共 50 条
  • [1] The X-ray Radiation Response of CdZnTe Crystal Nuclear Detector
    Dai, X. Y.
    Meng, H.
    Zhang, Y. L.
    Tao, J.
    Xu, R.
    Zhang, J. J.
    Huang, J.
    Wang, L.
    Tang, K.
    Min, J. H.
    Wang, L. J.
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY AND MANAGEMENT SCIENCE (ITMS 2015), 2015, 34 : 1296 - 1299
  • [2] CdZnTe detector as an x-ray spectrometer
    Miyajima, S
    Sakuragi, H
    Matsumoto, M
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 148 - 155
  • [3] Performance of a prototype CdZnTe detector module for hard X-ray astrophysics
    Slavis, KR
    Dowkontt, P
    Duttweiler, F
    Epstein, JW
    Hink, PL
    Huszar, GL
    Kalemci, E
    Leblanc, PC
    Matteson, JL
    Pelling, MR
    Rothschild, RE
    Stephan, E
    Tümer, T
    Visser, G
    [J]. X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 249 - 256
  • [4] CdZnTe detector in mammographic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 3959 - 3972
  • [5] CdZnTe detector in diagnostic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    Matsumoto, M
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1421 - 1429
  • [6] Progress in development on CdZnTe x-ray detector
    Zhou, Yongdong
    Zhou, Ning
    Zhang, Linhu
    Wang, Jin
    Wan, Aihua
    [J]. SEMICONDUCTOR PHOTODETECTORS III, 2006, 6119
  • [7] Improving CdZnTe X-ray detector performance by cooling and rise time discrimination
    Niemela, A
    Sipila, H
    Ivanov, VI
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 484 - 486
  • [8] Temporal pulsed x-ray response of CdZnTe: In detector
    Guo, Rong-Rong
    Xu, Ya-Dong
    Zha, Gang-Qiang
    Wang, Tao
    Jie, Wan-Qi
    [J]. CHINESE PHYSICS B, 2018, 27 (12)
  • [9] X-Ray Spectroscopy with a Room Temperature CdZnTe Detector
    Fritz, S. G.
    Shikhaliev, P. M.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [10] CdZnTe detector for combined x-ray CT and SPECT
    Iwata, K
    Hasegawa, BH
    Heanue, JA
    Bennett, PR
    Shah, KS
    Boles, CD
    Boser, BE
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 740 - 744