On the correlation between crystal morphology and X-ray performance of a CdZnTe detector

被引:2
|
作者
Bavdaz, M
Peacock, A
Nenonen, S
Jantunen, MA
Gagliardi, T
Tuomi, T
Hjelt, KT
Juvonen, M
Rantamaki, R
Kraft, S
Wedowski, M
Scholze, F
Ulm, G
McNally, PJ
Curley, J
Danilewsky, AN
机构
关键词
X-ray detectors; CdZnTe; X-ray astronomy; compound semiconductors;
D O I
10.1117/12.278895
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Using a CdZnTe sample detector, a variety of diagnostic tools are applied, so as to assess the crystal characteristics and to compare these to the X-ray response measured with synchrotron radiation. Correlations are found, such that X-ray response degrading processes can be identified. In this respect the performance of the detector is found to be limited by both large scale defects such as some grain boundaries and also pipes and by crystal imperfections, together with impurities and other crystal defects, both at the surface and in the bulk crystal. The relatively soft CdZnTe crystals are very sensitive to improper handling, producing particularly surface damage, which in turn deteriorates the detector performance, as is rather clearly established by photoluminescence measurements.
引用
收藏
页码:322 / 332
页数:11
相关论文
共 50 条
  • [31] X-ray diffraction topography and etched surface morphology of CdZnTe single crystals
    Sun Shi-Wen
    Sui Song-Yin
    He Li
    We Yan-Feng
    Zhou Chang-He
    Yu Hui-Xian
    Xu Chao
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2015, 34 (03) : 291 - 296
  • [32] SINGLE CRYSTAL CDS AS SOFT X-RAY DETECTOR
    HENRY, B
    COLE, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (02): : 90 - 92
  • [33] Spectrometric Performances of CdTe and CdZnTe Semiconductor Detector Arrays at High X-ray Flux
    Brambilla, A.
    Boudou, C.
    Ouvrier-Buffet, P.
    Mougel, F.
    Gonon, G.
    Rinkel, J.
    Verger, L.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1753 - +
  • [34] Large-area CdZnTe thick film based array X-ray detector
    Gao, Xiuying
    Sun, Hui
    Yang, Dingyu
    Wangyang, Peihua
    Zhang, Chaofu
    Zhu, Xinghua
    [J]. VACUUM, 2021, 183
  • [35] Progress in development of combined x-ray CT and SPECT system using CdZnTe detector
    Iwata, K
    Hasegawa, BH
    Boles, CD
    Bennett, PR
    Shah, KS
    Boser, BE
    [J]. MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 80 - 88
  • [36] Multiple-pixel x-ray linear detector based on single cdznte crystals
    Dvoryankin V.F.
    Dvoryankina G.G.
    Dikaev Y.M.
    Kudryashov A.A.
    Petrov A.G.
    Telegin A.A.
    [J]. Russian Microelectronics, 2015, 44 (4) : 241 - 243
  • [37] Combined x-ray CT and SPECT system using pixellated CdZnTe detector.
    Iwata, K
    Hasegawa, BH
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 32P - 32P
  • [38] Correlation between X-ray and γ-ray for Fermi blazars
    Bijun Li
    Haojing Zhang
    Xiong Zhang
    Dingrong Xiong
    Wenguang Liu
    YongJuan Cha
    Jin Li
    [J]. Astrophysics and Space Science, 2013, 347 : 349 - 355
  • [39] Correlation between X-ray and γ-ray for Fermi blazars
    Li, Bijun
    Zhang, Haojing
    Zhang, Xiong
    Xiong, Dingrong
    Liu, Wenguang
    Cha, YongJuan
    Li, Jin
    [J]. ASTROPHYSICS AND SPACE SCIENCE, 2013, 347 (02) : 349 - 355
  • [40] Charge-pump detector for X-ray correlation spectroscopy
    Carini, Gabriella A.
    Rehak, Pavel
    Chen, Wei
    Siddons, D. Peter
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 649 (01): : 75 - 77