Improving CdZnTe X-ray detector performance by cooling and rise time discrimination

被引:21
|
作者
Niemela, A
Sipila, H
Ivanov, VI
机构
[1] METOREX INT OY,FIN-2201 ESPOO,FINLAND
[2] BALTIC SCI INSTRUMENTS LTD,LV-1005 RIGA,LATVIA
关键词
D O I
10.1016/0168-9002(96)00028-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have studied several methods for improving CdZnTe detector performance, especially energy resolution and charge collection properties. Energy resolution can be greatly improved by cooling the detector to about -30 degrees C [1-3] which reduces the detector leakage current enabling the use of low-noise, pulsed-optical feedback preamplifiers and higher bias voltages. High bias voltages are necessary for more efficient charge collection which reduces spectrum background and peak tailing. Applying rise time discrimination circuitry to the linear amplifier reduces the tailing effect even further, especially at higher energies. Combining all these methods we tested a 16-mm(2), 3-mm thick Cd0.9Zn0.1Te detector crystal at -30 degrees C, and obtained energy resolutions of 292 eV at the 5.9-keV line of Fe-55, 600 eV at the 59.5-keV line of Am-241, and 780 eV at the 88-keV line of Cd-109. Another 9-mm(2), 3-mm thick Cd0.9Zn0.1Te detector crystal showed a charge collection problem at -30 degrees C which caused all spectrum peaks to be doublets. However, the rise time discriminator removed the ghost peaks form the spectrum almost completely, and improved the energy resolution and background.
引用
收藏
页码:484 / 486
页数:3
相关论文
共 50 条
  • [1] CdZnTe detector as an x-ray spectrometer
    Miyajima, S
    Sakuragi, H
    Matsumoto, M
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 148 - 155
  • [2] High-resolution p-i-n CdTe and CdZnTe X-ray detectors with cooling and rise-time discrimination
    Niemela, A
    Sipila, H
    Ivanov, VI
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1476 - 1480
  • [3] High-resolution p-i-n CdTe and CdZnTe x-ray detectors with cooling and rise-time discrimination
    Niemela, A
    Sipila, H
    Ivanov, VI
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 549 - 553
  • [4] Performance of a prototype CdZnTe detector module for hard X-ray astrophysics
    Slavis, KR
    Dowkontt, P
    Duttweiler, F
    Epstein, JW
    Hink, PL
    Huszar, GL
    Kalemci, E
    Leblanc, PC
    Matteson, JL
    Pelling, MR
    Rothschild, RE
    Stephan, E
    Tümer, T
    Visser, G
    [J]. X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 249 - 256
  • [5] On the correlation between crystal morphology and X-ray performance of a CdZnTe detector
    Bavdaz, M
    Peacock, A
    Nenonen, S
    Jantunen, MA
    Gagliardi, T
    Tuomi, T
    Hjelt, KT
    Juvonen, M
    Rantamaki, R
    Kraft, S
    Wedowski, M
    Scholze, F
    Ulm, G
    McNally, PJ
    Curley, J
    Danilewsky, AN
    [J]. EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 322 - 332
  • [6] CdZnTe detector in mammographic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 3959 - 3972
  • [7] CdZnTe detector in diagnostic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    Matsumoto, M
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1421 - 1429
  • [8] Progress in development on CdZnTe x-ray detector
    Zhou, Yongdong
    Zhou, Ning
    Zhang, Linhu
    Wang, Jin
    Wan, Aihua
    [J]. SEMICONDUCTOR PHOTODETECTORS III, 2006, 6119
  • [9] Temporal pulsed x-ray response of CdZnTe: In detector
    Guo, Rong-Rong
    Xu, Ya-Dong
    Zha, Gang-Qiang
    Wang, Tao
    Jie, Wan-Qi
    [J]. CHINESE PHYSICS B, 2018, 27 (12)
  • [10] X-Ray Spectroscopy with a Room Temperature CdZnTe Detector
    Fritz, S. G.
    Shikhaliev, P. M.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)