Occupational eye lens doses in interventional cardiology. A multicentric study

被引:19
|
作者
Sanchez, R. M. [1 ]
Vano, E. [1 ,2 ]
Fernandez, J. M. [1 ,2 ]
Pifarre, X. [3 ]
Ordiales, J. M. [4 ]
Rovira, J. J. [5 ]
Carrera, F. [6 ]
Goicolea, J. [7 ]
Fernandez-Ortiz, A. [8 ]
机构
[1] Hosp Clin San Carlos, Inst Invest Sanitaria, Med Phys, Madrid, Spain
[2] Univ Complutense Madrid, Fac Med, Dept Radiol, E-28040 Madrid, Spain
[3] Hosp Puerta de Hierro, Med Phys, Majadahonda, Spain
[4] Hosp de Merida, Med Phys, Merida, Spain
[5] Hosp Valle De Hebron, Med Phys, Barcelona, Spain
[6] Hosp Juan Ramon Jimenez, Med Phys, Huelva, Spain
[7] Hosp Puerta de Hierro, Intervent Cardiol, Majadahonda, Spain
[8] Hosp Clin San Carlos, Inst Invest Sanitaria, Intervent Cardiol, Madrid, Spain
关键词
radiological protection; interventional cardiology; occupational dose; eye lens; ATOMIC-BOMB SURVIVORS; RADIATION-EXPOSURE; MEDICAL STAFF; PERSONAL DOSIMETERS; BRAIN-TUMORS; RADIOLOGY; CATARACT; PROJECT; PATIENT; ALARM;
D O I
10.1088/0952-4746/36/1/133
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
New European regulation regarding radiological protection of workers and more specifically the new occupational dose limit for the eye lens recently reduced to 20 mSv yr(-1) may affect interventional cardiologists. This paper presents a set of measurements of occupational doses performed in five interventional cardiology centres and then compared with the new dose limit. The measurement of occupational doses was performed over the apron at chest level using electronic dosemeters recording H-p(10). In one of the centres, scatter dose at goggles was also measured with optically stimulated luminescence dosemeters calibrated in terms of H-p(0.07). An average H-p(10) over the apron of 46 mu Sv/procedure was measured for cardiologists. Lower doses were noted in other professionals like second cardiologists, nurses or anaesthetists. Procedures for valvular and other structural heart diseases involved the highest occupational doses, averaging over 100 mu Sv/procedure. Important differences in occupational doses among centres may be indicative of different radiation protection habits. The new occupational dose limit for the eye lens is likely to be exceeded by those among the interventionalists who do not use protection tools (ceiling suspended screen and/or goggles) even with standard workloads.
引用
收藏
页码:133 / 143
页数:11
相关论文
共 50 条
  • [31] Occupational radiation exposure to the lens of the eye in interventional radiology
    Moriarty, Heather K.
    Clements, Warren
    Phan, Tuan
    Wang, Sherry
    Goh, Gerard S.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2022, 66 (01) : 34 - 40
  • [32] Eye Lens Radiation Exposure in Greek Interventional Cardiology Article
    Thrapsanioti, Zoi
    Askounis, Panagiotis
    Datseris, Ioannis
    Diamanti, Ramza Anastasia
    Papathanasiou, Miltiadis
    Carinou, Eleftheria
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 344 - 356
  • [33] Staff eye lens dose in interventional radiology and cardiology in Finland
    Pekkarinen, Antti
    Lindholm, Carita
    Kortesniemi, Mika
    Siiskonen, Teemu
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 98 : 1 - 7
  • [34] REC: Interventional Cardiology. Fulfilling an unmet need
    Perez de Prado, Armando
    Cid, Belen
    Rodriguez Leor, Oriol
    Moreno, Raul
    [J]. REC-INTERVENTIONAL CARDIOLOGY, 2019, 1 (01): : 1 - 1
  • [35] Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures
    Efstathopoulos, E. P.
    Pantos, I.
    Andreou, M.
    Gkatzis, A.
    Carinou, E.
    Koukorava, C.
    Kelekis, N. L.
    Brountzos, E.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997): : 70 - 77
  • [36] OCCUPATIONAL DOSES FOR THE FIRST AND SECOND OPERATORS IN LEBANESE INTERVENTIONAL CARDIOLOGY SUITES
    Rizk, C.
    Farah, J.
    Fares, G.
    Vanhavere, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 438 - 447
  • [37] A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology
    Domienik, J.
    Brodecki, M.
    Rusicka, D.
    [J]. RADIATION MEASUREMENTS, 2012, 47 (02) : 130 - 138
  • [38] Correlation between eye lens doses and over apron doses in interventional procedures
    Gracia-Ochoa, M.
    Candela-Juan, C.
    Vilar-Palop, J.
    Ruiz Rodriguez, J. C.
    Soriano Cruz, A.
    Palma Copete, J. D.
    Pujades Claumarchirant, M. C.
    Llorca Domaica, N.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 10 - 17
  • [39] Current role of intracoronary Doppler flow in interventional cardiology.
    Kern, MJ
    [J]. ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1997, 90 : 41 - 50
  • [40] Assessment of eye doses to staff involved in interventional cardiology procedures in Kuwait
    Alnaaimi, Meshari
    Alduaij, Mousa
    Shenawy, Faisal
    Algaily, Musab
    Mohammedzein, Talal
    Shaaban, Mohamed
    Rehani, Madan M.
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2021, 60 (04) : 639 - 645