Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

被引:39
|
作者
Ciftci, E [1 ]
Anik, Y [1 ]
Arslan, A [1 ]
Akansel, G [1 ]
Sarisoy, T [1 ]
Demirci, A [1 ]
机构
[1] Kocaeli Univ, Sch Radiol, TR-41100 Kocaeli, Turkey
关键词
magnetic resonance imaging; 3D turbo spin echo sequence; trigerninat nerve; abducens nerve; facial nerve; vestibulocochlear nerve;
D O I
10.1016/j.ejrad.2003.10.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P < 0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE(.)in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 50 条
  • [21] T2-WEIGHTED MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A RAPID 3D-PSIF SEQUENCE IN 72 PATIENTS
    TAUPITZ, MC
    SPEIDEL, A
    HAMM, B
    DEIMLING, M
    BOCK, A
    WOLF, K
    RADIOLOGY, 1992, 185 : 140 - 140
  • [22] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03): : 395 - 400
  • [23] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Peng Lv
    Yuanyuan Dai
    Jiang Lin
    Weisheng Zhang
    Hao Liu
    Hui Liu
    Xiao Tang
    The International Journal of Cardiovascular Imaging, 2017, 33 : 395 - 400
  • [24] Clinical Value of 3D T2*-weighted Imaging with Multi-echo Acquisition: Comparison with Conventional 2D T2*-weighted Imaging and 3D Phase-sensitive MR Imaging
    Kunimatsu, Akira
    Suzuki, Yuichi
    Hagiwara, Kazuchika
    Sasaki, Hiroki
    Mori, Harushi
    Katsura, Masaki
    Ohtomo, Kuni
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (03) : 205 - 211
  • [25] Diagnosis of spinal dural arteriovenous fistula using 3D T2-weighted imaging
    Kralik, Stephen F.
    Murph, Daniel
    Mehta, Peter
    O'Neill, Darren P.
    NEURORADIOLOGY, 2017, 59 (10) : 997 - 1002
  • [26] Diagnosis of spinal dural arteriovenous fistula using 3D T2-weighted imaging
    Stephen F. Kralik
    Daniel Murph
    Peter Mehta
    Darren P. O’Neill
    Neuroradiology, 2017, 59 : 997 - 1002
  • [27] Comparison of FSE T2W and 3D FIESTA sequences in the evaluation of posterior fossa cranial nerves with MR cisternography
    Hatipoglu, Hatice Guel
    Durakoglugil, Tugba
    Ciliz, Deniz
    Yueksel, Enis
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2007, 13 (02): : 56 - 60
  • [28] Lateral lipomyelomeningocele of the hemicord with split cord malformation type I revealed by 3D heavily T2-weighted MR imaging
    Nobuya Murakami
    Takato Morioka
    Masako Ichiyama
    Ryoko Nakamura
    Nobuko Kawamura
    Child's Nervous System, 2017, 33 : 993 - 997
  • [29] Lateral lipomyelomeningocele of the hemicord with split cord malformation type I revealed by 3D heavily T2-weighted MR imaging
    Murakami, Nobuya
    Morioka, Takato
    Ichiyama, Masako
    Nakamura, Ryoko
    Kawamura, Nobuko
    CHILDS NERVOUS SYSTEM, 2017, 33 (06) : 993 - 997
  • [30] Preliminary Clinical Experience at 3 T With a 3D T2-Weighted Sequence Compared With Multiplanar 2D for Evaluation of the Female Pelvis
    Hecht, Elizabeth M.
    Yitta, Silaja
    Lim, Ruth P.
    Fitzgerald, Erin F.
    Storey, Pippa
    Babb, James S.
    Bani-baker, Kamil O.
    Bennett, Genevieve L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W346 - W352