Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

被引:39
|
作者
Ciftci, E [1 ]
Anik, Y [1 ]
Arslan, A [1 ]
Akansel, G [1 ]
Sarisoy, T [1 ]
Demirci, A [1 ]
机构
[1] Kocaeli Univ, Sch Radiol, TR-41100 Kocaeli, Turkey
关键词
magnetic resonance imaging; 3D turbo spin echo sequence; trigerninat nerve; abducens nerve; facial nerve; vestibulocochlear nerve;
D O I
10.1016/j.ejrad.2003.10.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P < 0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE(.)in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 50 条
  • [41] Cerebral microbleeds: Accelerated 3D T2*-weighted GRE MR imaging versus conventional 2D T2*-weighted GRE MR imaging for detection
    Vernooij, Meike W.
    Ikram, M. Arfan
    Wielopolski, Piotr A.
    Krestin, Gabriel P.
    Breteler, Monique M. B.
    van der Lugt, Aad
    RADIOLOGY, 2008, 248 (01) : 272 - 277
  • [42] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [43] Systematical Radiologic Comparison of 3D-T2W MR Sequences for Cranial Nerve Imaging at 3 T
    Wang, Xuan
    Li, Yue-Hua
    Li, Ming-Hua
    Lu, Jing
    NEUROSURGERY QUARTERLY, 2013, 23 (04) : 268 - 274
  • [44] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Cai, Larry
    Yeh, Benjamin M.
    Westphalen, Antonio C.
    Roberts, John
    Wang, Zhen J.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 842 - 850
  • [45] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Larry Cai
    Benjamin M. Yeh
    Antonio C. Westphalen
    John Roberts
    Zhen J. Wang
    Abdominal Radiology, 2017, 42 : 842 - 850
  • [46] High-resolution T2-weighted MR imaging of the inner ear using a long echo-train-length 3D east spin-echo sequence
    Naganawa, S
    Yamakawa, K
    Fukatsu, H
    Ishigaki, T
    Nakashima, T
    Sugimoto, H
    Aoki, I
    Miyazaki, M
    Takai, H
    EUROPEAN RADIOLOGY, 1996, 6 (03) : 369 - 374
  • [47] Delayed echo train turbo spin-echo (DELET-TSE): A new sequence for improved T2-weighted contrast in MR imaging of focal liver lesions
    Taupitz, M
    Deimling, N
    Malcher, R
    Kivelitz, DE
    Hamm, BK
    RADIOLOGY, 1998, 209P : 294 - 294
  • [48] MR imaging of the internal auditory canal and inner ear at 3T: Comparison between 3D driven equilibrium and 3D balanced fast field echo sequences
    Byun, Jun Soo
    Kim, Hyung-Jin
    Yim, You Jeong
    Kim, Sung Tae
    Jeon, Pyoung
    Kim, Keon Ha
    Kim, Sam Soo
    Jeon, Yong Hwan
    Lee, Jiwon
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (03) : 212 - 218
  • [49] Defining the incremental value of 3D T2-weighted imaging in the assessment of prostate cancer extracapsular extension
    Caglic, Iztok
    Brzan, Petra Povalej
    Warren, Anne Y.
    Bratt, Ola
    Shah, Nimish
    Barrett, Tristan
    EUROPEAN RADIOLOGY, 2019, 29 (10) : 5488 - 5497
  • [50] Assessment of regional differences in myocardial blood flow using T2-weighted 3D BOLD imaging
    Wright, KB
    Klocke, FJ
    Deshpande, VS
    Zheng, J
    Harris, KR
    Tang, R
    Finn, JP
    Li, DB
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 573 - 578