Characterization of continuous and pulsed emission modes of a hybrid micro focus x-ray source for medical imaging applications

被引:12
|
作者
Ghani, Muhammad U. [1 ,2 ]
Wong, Molly D. [1 ,2 ]
Ren, Liqiang [1 ,2 ]
Wu, Di [1 ,2 ]
Zheng, Bin [1 ,2 ]
Rong, John. X. [3 ]
Wu, Xizeng [4 ]
Liu, Hong [1 ,2 ]
机构
[1] Univ Oklahoma, Ctr Biomed Engn, Norman, OK 73019 USA
[2] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[4] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35249 USA
关键词
Pulsed beam emission; Spatial resolution; Beam quality; Continuous beam; SPATIAL-RESOLUTION CHARACTERISTICS; HIGH-ENERGY; COMPUTED RADIOGRAPHY; BREAST CT; CONTRAST; TOMOGRAPHY; VASCULATURE; DEPTH; SLIT;
D O I
10.1016/j.nima.2017.02.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study was to quantitatively characterize a micro focus x-ray tube that can operate in both continuous and pulsed emission modes. The micro focus x-ray source (Model L9181-06, Hamamatsu Photonics, Japan) has a varying focal spot size ranging from 16 mu m to 50 mu m as the source output power changes from 10 to 39 W. We measured the source output, beam quality, focal spot sizes, kV accuracy, spectra shapes and spatial resolution. Source output was measured using an ionization chamber for various tube voltages (kVs) with varying current (mu A) and distances. The beam quality was measured in terms of half value layer (HVL), kV accuracy was measured with a non-invasive kV meter, and the spectra was measured using a compact integrated spectrometer system. The focal spot sizes were measured using a slit method with a CCD detector with a pixel pitch of 22 mu m. The spatial resolution teas quantitatively measured using the slit method with a CMOS flat panel detector with a 50 mu m pixel pitch, and compared to the qualitative results obtained by imaging a contrast bar pattern. The focal spot sizes in the vertical direction were smaller than that of the horizontal direction, the impact of which was visible when comparing the spatial resolution values. Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam quality, spectra shape and spatial resolution effects. There were no significantly large differences, thus providing the motivation for future studies to design and develop stable and robust cone beam imaging systems for various diagnostic applications.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [41] BriXS, a new X-ray inverse Compton source for medical applications
    Cardarelli, P.
    Bacci, A.
    Calandrino, R.
    Canella, F.
    Castriconi, R.
    Cialdi, S.
    Del Vecchio, A.
    di Franco, F.
    Drebot, I
    Gambaccini, M.
    Giannotti, D.
    Loria, A.
    Mettivier, G.
    Patern, G.
    Petrillo, V
    Conti, M. Rossetti
    Russo, P.
    Sarno, A.
    Suerra, E.
    Taibi, A.
    Serafini, L.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 127 - 137
  • [42] Laser electron-beam X-ray source for medical applications
    Bessonov, EG
    Vinogradov, AV
    Gorbunkov, MV
    Tur'yanskii, AG
    Feshchenko, RM
    Shabalin, YV
    PHYSICS-USPEKHI, 2003, 46 (08) : 872 - 876
  • [43] Characterization of multilayer coated replicated Wolter optics for imaging X-ray emission from pulsed power experiments
    Ames, A.
    Ampleford, D.
    Bourdon, C.
    Bruni, R.
    Kilaru, K.
    Kozioziemski, B.
    Pivovaroff, M.
    Ramsey, B.
    Romaine, S.
    Vogel, J. K.
    Walton, C.
    Wu, M.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY VIII, 2017, 10399
  • [44] Respiratory-gated micro-CT using a carbon nanotube based micro-focus field emission x-ray source
    Cao, Guohua
    Lee, Yueh Z.
    Liu, Zejian
    Rajaram, Ramya
    Peng, Rui
    Calderon-Colon, Xiomara
    An, Lei
    Wang, Peng
    Phan, Tuyen
    Lalush, David
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [45] Crossed planar X-ray lenses made from nickel for X-ray micro focusing and imaging applications
    Nazmov, V.
    Reznikova, E.
    Last, A.
    Mohr, J.
    Saile, V.
    DiMichiel, M.
    Gottert, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 582 (01): : 120 - 122
  • [46] Imaging micro-well detectors for X-ray and gamma-ray applications
    Black, JK
    Deines-Jones, P
    Hunter, SD
    Jahoda, K
    Huang, J
    Jackson, TN
    Klauk, H
    Qian, W
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 313 - 323
  • [47] X-ray micro-computed tomography imaging for coal characterization
    School of Petroleum Engineering, University of New South Wales, Australia
    不详
    Soc. Pet. Eng. - SPE Asia Pac. Unconv. Resour. Conf. Exhib.,
  • [48] Potential of polycapillary optics for hard x-ray medical imaging applications
    Wang, L
    Gibson, WM
    MacDonald, CA
    EUV, X-RAY, AND NEUTRON OPTICS AND SOURCES, 1999, 3767 : 102 - 112
  • [49] Denoising by using multineural networks for medical X-ray imaging applications
    Li, Yeqiu
    Lu, Jianming
    Wang, Ling
    Takashi, Yahagi
    NEUROCOMPUTING, 2009, 72 (13-15) : 2884 - 2891
  • [50] Spectral and dual-energy X-ray imaging for medical applications
    Fredenberg, Erik
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 74 - 87