Characterization of continuous and pulsed emission modes of a hybrid micro focus x-ray source for medical imaging applications

被引:12
|
作者
Ghani, Muhammad U. [1 ,2 ]
Wong, Molly D. [1 ,2 ]
Ren, Liqiang [1 ,2 ]
Wu, Di [1 ,2 ]
Zheng, Bin [1 ,2 ]
Rong, John. X. [3 ]
Wu, Xizeng [4 ]
Liu, Hong [1 ,2 ]
机构
[1] Univ Oklahoma, Ctr Biomed Engn, Norman, OK 73019 USA
[2] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[4] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35249 USA
关键词
Pulsed beam emission; Spatial resolution; Beam quality; Continuous beam; SPATIAL-RESOLUTION CHARACTERISTICS; HIGH-ENERGY; COMPUTED RADIOGRAPHY; BREAST CT; CONTRAST; TOMOGRAPHY; VASCULATURE; DEPTH; SLIT;
D O I
10.1016/j.nima.2017.02.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study was to quantitatively characterize a micro focus x-ray tube that can operate in both continuous and pulsed emission modes. The micro focus x-ray source (Model L9181-06, Hamamatsu Photonics, Japan) has a varying focal spot size ranging from 16 mu m to 50 mu m as the source output power changes from 10 to 39 W. We measured the source output, beam quality, focal spot sizes, kV accuracy, spectra shapes and spatial resolution. Source output was measured using an ionization chamber for various tube voltages (kVs) with varying current (mu A) and distances. The beam quality was measured in terms of half value layer (HVL), kV accuracy was measured with a non-invasive kV meter, and the spectra was measured using a compact integrated spectrometer system. The focal spot sizes were measured using a slit method with a CCD detector with a pixel pitch of 22 mu m. The spatial resolution teas quantitatively measured using the slit method with a CMOS flat panel detector with a 50 mu m pixel pitch, and compared to the qualitative results obtained by imaging a contrast bar pattern. The focal spot sizes in the vertical direction were smaller than that of the horizontal direction, the impact of which was visible when comparing the spatial resolution values. Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam quality, spectra shape and spatial resolution effects. There were no significantly large differences, thus providing the motivation for future studies to design and develop stable and robust cone beam imaging systems for various diagnostic applications.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [31] X-ray microscopy and imaging of Caenorhabditis elegans nematode using a laser plasma pulsed x-ray source
    Poletti, G
    Orsini, F
    Ullschmied, J
    Skala, J
    Kralikova, B
    Pfeifer, M
    Kadlec, C
    Mocek, T
    Präg, A
    Cotelli, F
    Lamia, CL
    Batani, D
    Bernardinello, A
    Desai, T
    Zullini, A
    LASER-GENERATED AND OTHER LABORATORY X-RAY AND EUV SOURCES, OPTICS, AND APPLICATIONS, 2003, 5196 : 375 - 382
  • [32] Phase sensitive X-ray imaging: Towards medical applications
    Kottler, Christian
    Revol, Vincent
    Maake, Caroline
    Kaufmann, Rolf
    Urban, Claus
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2445 - 2448
  • [33] Characterization of digital systems used in medical X-ray imaging
    Perez, A. M. M. M.
    Poletti, M. E.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [34] Transmission and emission x-ray microscopy: operation modes, contrast mechanisms and applications
    Kaulich, Burkhard
    Thibault, Pierre
    Gianoncelli, Alessandra
    Kiskinova, Maya
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2011, 23 (08)
  • [35] A COMPACT HARD X-RAY SOURCE FOR MEDICAL IMAGING AND BIOMOLECULAR STUDIES
    CLINE, DB
    GARREN, AA
    GREEN, MA
    KOLONKO, J
    MADURA, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 821 - 823
  • [36] Design and Characterization of a Carbon Nanotube based Micro-Focus X-Ray Tube for Small Animal Imaging
    Sultana, Shabana
    Calderon-Colon, Xiomara
    Cao, Guohua
    Zhou, Otto
    Lu, Jianping
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [37] Portable hard x-ray source for nondestructive testing and medical imaging
    Boyer, CN
    Holland, GE
    Seely, JF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (06): : 2524 - 2530
  • [38] Potentiality of a table top plasma focus as X-ray source: Radiographic applications
    Pavez, Cristian
    Zambra, Marcelo
    Veloso, Felipe
    Moreno, Jose
    Soto, Leopoldo
    15TH INTERNATIONAL CONGRESS ON PLASMA PHYSICS (ICPP2010) & 13TH LATIN AMERICAN WORKSHOP ON PLASMA PHYSICS (LAWPP2010), 2014, 511
  • [39] Laboratory x-ray micro imaging: Sources, optics, systems and applications
    Hertz, H. M.
    Bertilson, M.
    Chubarova, E.
    Ewald, J.
    Gleber, S-C
    Hemberg, O.
    Henriksson, M.
    von Hofsten, O.
    Holmberg, A.
    Lindblom, M.
    Mudry, E.
    Otendal, M.
    Reinspach, J.
    Schlie, M.
    Skoglund, P.
    Takman, P.
    Thieme, J.
    Sedlmair, J.
    Tjornhammar, R.
    Tuohimaa, T.
    Vita, M.
    Vogt, U.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [40] Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging
    Mascali, David
    Castro, Giuseppe
    Biri, Sandor
    Racz, Richard
    Palinkas, Jozsef
    Caliri, Claudia
    Celona, Luigi
    Neri, Lorenzo
    Romano, Francesco Paolo
    Torrisi, Giuseppe
    Gammino, Santo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):