Characterization of continuous and pulsed emission modes of a hybrid micro focus x-ray source for medical imaging applications

被引:12
|
作者
Ghani, Muhammad U. [1 ,2 ]
Wong, Molly D. [1 ,2 ]
Ren, Liqiang [1 ,2 ]
Wu, Di [1 ,2 ]
Zheng, Bin [1 ,2 ]
Rong, John. X. [3 ]
Wu, Xizeng [4 ]
Liu, Hong [1 ,2 ]
机构
[1] Univ Oklahoma, Ctr Biomed Engn, Norman, OK 73019 USA
[2] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[4] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35249 USA
关键词
Pulsed beam emission; Spatial resolution; Beam quality; Continuous beam; SPATIAL-RESOLUTION CHARACTERISTICS; HIGH-ENERGY; COMPUTED RADIOGRAPHY; BREAST CT; CONTRAST; TOMOGRAPHY; VASCULATURE; DEPTH; SLIT;
D O I
10.1016/j.nima.2017.02.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study was to quantitatively characterize a micro focus x-ray tube that can operate in both continuous and pulsed emission modes. The micro focus x-ray source (Model L9181-06, Hamamatsu Photonics, Japan) has a varying focal spot size ranging from 16 mu m to 50 mu m as the source output power changes from 10 to 39 W. We measured the source output, beam quality, focal spot sizes, kV accuracy, spectra shapes and spatial resolution. Source output was measured using an ionization chamber for various tube voltages (kVs) with varying current (mu A) and distances. The beam quality was measured in terms of half value layer (HVL), kV accuracy was measured with a non-invasive kV meter, and the spectra was measured using a compact integrated spectrometer system. The focal spot sizes were measured using a slit method with a CCD detector with a pixel pitch of 22 mu m. The spatial resolution teas quantitatively measured using the slit method with a CMOS flat panel detector with a 50 mu m pixel pitch, and compared to the qualitative results obtained by imaging a contrast bar pattern. The focal spot sizes in the vertical direction were smaller than that of the horizontal direction, the impact of which was visible when comparing the spatial resolution values. Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam quality, spectra shape and spatial resolution effects. There were no significantly large differences, thus providing the motivation for future studies to design and develop stable and robust cone beam imaging systems for various diagnostic applications.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [21] Optimization of Focusing Structure for a Micro-Focus X-ray Source
    Wang, Junfan
    Guo, Yajie
    Zhu, Haifeng
    Li, Baohong
    Zhang, Yu
    Deng, Shaozhi
    Xu, Ningsheng
    Chen, Jun
    2021 34TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2021, : 191 - 192
  • [22] CHARACTERIZATION OF A PULSED X-RAY SOURCE FOR FLUORESCENT LIFETIME MEASUREMENTS
    BLANKESPOOR, SC
    DERENZO, SE
    MOSES, WW
    ROSSINGTON, CS
    ITO, M
    OBA, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 698 - 702
  • [23] Commissioning of a laser-plasma X-Ray micro-focus source for phase contrast imaging
    Martin, L.
    Benlliure, J.
    Cortina, D.
    Gonzalez, D.
    Llerena, J. J.
    Pena, J.
    Ruiz, C.
    RELATIVISTIC PLASMA WAVES AND PARTICLE BEAMS AS COHERENT AND INCOHERENT RADIATION SOURCES III, 2019, 11036
  • [24] A BRIGHT PULSED X-RAY SOURCE FOR SOFT-X-RAY RESEARCH AND PROCESSING APPLICATIONS
    PEARLMAN, JS
    RIORDAN, JC
    KOLB, AC
    RADIATION PHYSICS AND CHEMISTRY, 1985, 25 (4-6): : 709 - 718
  • [25] Field emission arrays for tomographic medical x-ray imaging
    Schwoebel, P. R.
    Holland, C. E.
    Spindt, C. A.
    2006 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE HELD JOINTLY WITH 2006 IEEE INTERNATIONAL VACUUM ELECTRON SOURCES, 2006, : 511 - 511
  • [26] A dual-functional micro-focus X-ray source based on carbon nanotube field emission
    Huang, Weijun
    Huang, Yunmi
    Liu, Ruizi
    Zhu, Wei
    Kang, Song
    Qian, Weijin
    Dong, Changkun
    DIAMOND AND RELATED MATERIALS, 2022, 125
  • [27] Enhancing X-ray Emission of Cold Cathode Flat-Panel X-ray Source by Pulsed Driving
    Fan, Ruowen
    Kang, Song
    Zhang, Guofu
    She, Juncong
    Deng, Shaozhi
    Chen, Jun
    2024 37TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE, IVNC 2024, 2024,
  • [28] Laser-electron X-ray source for medical applications
    Bessonov, EG
    Vinogradov, AV
    Tourianskii, AG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (05) : 718 - 723
  • [29] Applications of the generalized X-ray diffraction enhanced imaging in the medical imaging
    Maksimenko, Anton
    Hashimoto, Eiko
    Ando, Masami
    Sugiyama, Hiroshi
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1972 - +
  • [30] Analyzer-based phase-contrast imaging system using a micro focus x-ray source
    Zhou, Wei
    Majidi, Keivan