Characterization of continuous and pulsed emission modes of a hybrid micro focus x-ray source for medical imaging applications

被引:12
|
作者
Ghani, Muhammad U. [1 ,2 ]
Wong, Molly D. [1 ,2 ]
Ren, Liqiang [1 ,2 ]
Wu, Di [1 ,2 ]
Zheng, Bin [1 ,2 ]
Rong, John. X. [3 ]
Wu, Xizeng [4 ]
Liu, Hong [1 ,2 ]
机构
[1] Univ Oklahoma, Ctr Biomed Engn, Norman, OK 73019 USA
[2] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[4] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35249 USA
关键词
Pulsed beam emission; Spatial resolution; Beam quality; Continuous beam; SPATIAL-RESOLUTION CHARACTERISTICS; HIGH-ENERGY; COMPUTED RADIOGRAPHY; BREAST CT; CONTRAST; TOMOGRAPHY; VASCULATURE; DEPTH; SLIT;
D O I
10.1016/j.nima.2017.02.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study was to quantitatively characterize a micro focus x-ray tube that can operate in both continuous and pulsed emission modes. The micro focus x-ray source (Model L9181-06, Hamamatsu Photonics, Japan) has a varying focal spot size ranging from 16 mu m to 50 mu m as the source output power changes from 10 to 39 W. We measured the source output, beam quality, focal spot sizes, kV accuracy, spectra shapes and spatial resolution. Source output was measured using an ionization chamber for various tube voltages (kVs) with varying current (mu A) and distances. The beam quality was measured in terms of half value layer (HVL), kV accuracy was measured with a non-invasive kV meter, and the spectra was measured using a compact integrated spectrometer system. The focal spot sizes were measured using a slit method with a CCD detector with a pixel pitch of 22 mu m. The spatial resolution teas quantitatively measured using the slit method with a CMOS flat panel detector with a 50 mu m pixel pitch, and compared to the qualitative results obtained by imaging a contrast bar pattern. The focal spot sizes in the vertical direction were smaller than that of the horizontal direction, the impact of which was visible when comparing the spatial resolution values. Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam quality, spectra shape and spatial resolution effects. There were no significantly large differences, thus providing the motivation for future studies to design and develop stable and robust cone beam imaging systems for various diagnostic applications.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [1] x-Ray Source: Continuous and Pulsed Modes
    A. B. Dorin
    M. V. Petrovskii
    I. A. Tolokonnikov
    Atomic Energy, 2003, 95 : 512 - 513
  • [2] X-ray source: Continuous and pulsed modes
    Dorin, AB
    Petrovskii, MV
    Tolokonnikov, IA
    ATOMIC ENERGY, 2003, 95 (01) : 512 - 513
  • [3] Design, hard x-ray source characterization and applications of a plasma focus tailored for flash hard x-ray imaging
    Knoblauch, P.
    Di Lorenzo, F.
    Raspa, V.
    Clausse, A.
    Moreno, C.
    PHYSICA SCRIPTA, 2008, T131
  • [4] Phase contrast imaging using a micro focus x-ray source
    Zhou, Wei
    Majidi, Keivan
    Brankov, Jovan G.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IX, 2014, 9207
  • [5] A pulsed hard x-ray source for nondestructive testing and medical imaging
    Boyer, CN
    Holland, GE
    Seely, JF
    COHERENT ELECTRON-BEAM X-RAY SOURCES: TECHNIQUES AND APPLICATIONS, 1997, 3154 : 16 - 26
  • [6] Characterization of X-Ray Source and Detector Geometry for the Compton Backscatter Imaging System for Medical Applications
    Juneja, B.
    Doxsee, K.
    Gilland, D.
    Hintenlang, D.
    Dugan, E.
    Bova, F.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] RELIABLE CARBON NANOTUBE BASED MICRO WIRE FOR MICRO FOCUS FIELD EMISSION X-RAY SOURCE BY MICROMACHINING
    Sun, Bin
    Wang, Yan
    Deng, Min
    Ding, Guifu
    2017 19TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2017, : 1967 - 1970
  • [8] X-Ray Tubes in Medical Imaging Applications
    Fuerst, Jens
    VAKUUM IN FORSCHUNG UND PRAXIS, 2015, 27 (05) : 17 - 21
  • [9] MEDICAL IMAGING APPLICATIONS OF X-RAY PHOSPHORS
    ISSLER, SL
    BEUTEL, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 66 - IEC
  • [10] In-line phase contrast imaging using a micro-focus X-ray source
    Yu Ai-Min
    Li Zheng
    Zhang Di
    Huang Zhi-Feng
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (11): : 1119 - 1122