Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: Verification of intracardiac signals with a second circular mapping catheter

被引:18
|
作者
Rosso, Raphael [1 ]
Halkin, Amir
Michowitz, Yoav
Belhassen, Bernard
Glick, Aharon
Viskin, Sami
机构
[1] Tel Aviv Sourasky Med Ctr, Dept Cardiol, IL-64239 Tel Aviv, Israel
关键词
Atrial fibrillation; Radiofrequency ablation; Pulmonary veins; PULMONARY VEIN POTENTIALS; PATIENT;
D O I
10.1016/j.hrthm.2013.12.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND During radiofrequency (RE) ablation of paroxysmal atrial fibrillation, a circular multielectrode recording "lasso" catheter is generally positioned within each pulmonary vein (PV) to determine when pulmonary vein potentials (PVPs) are present and when they have been ablated. The new irrigated multipolar nMARQ circular ablation catheter is positioned within the left atrium to create contiguous circular ablation lines around each PV ostium. OBJECTIVE To determine whether the recordings obtained from the nMARQ catheter position around the PV ostium accurately reproduce the recordings obtained from a Lasso catheter positioned within that vein. METHODS In 10 patients undergoing RF ablation of paroxysmaL atrial fibrillation, we placed an nMARQ and a lasso catheter around and within each PV, respectively. Recordings obtained from both catheters at baseline and after RE ablation were compared. RESULTS At baseline, recordings of PVPs in both catheters were concordant in 92% of all PVs. However, after RF delivery, the concordance between the nMARQ and lasso recordings was poor. The discordant result most commonly observed was disappearance of "PVPs" from the nMARQ catheter with persistence of PVPs in the Lasso catheter (12 of 39 [30%]). Conversely, the delivery of RE frequently resulted in fragmented electrograms (pseudo-PVPs) on the nMARQ catheter despite evidence of PV isolation by lasso catheter recordings. CONCLUSIONS The use of an nMARQ catheter alone, as currently recommended, may Lead to underestimation and overestimation of the number of RE applications required to achieve PV isolation.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [41] Intracardiac echocardiography during catheter ablation of atrial fibrillation
    Saliba, Walid
    Thomas, James
    EUROPACE, 2008, 10 : 42 - 47
  • [42] The use of Intracardiac Echocardiography in Catheter Ablation of Atrial Fibrillation
    Sousonis, Vasileios
    Asvestas, Dimitrios
    Vavouris, Emmanouil
    Karanikas, Stavros
    Ypsilanti, Elissavet
    Tzeis, Stylianos
    CURRENT CARDIOLOGY REPORTS, 2024, 26 (09) : 893 - 901
  • [43] Procedural and clinical impact of a new open-irrigated radiofrequency catheter with direct force measurement on ablation of paroxysmal atrial fibrillation
    Sigmund, E.
    Puererfellner, H.
    Derndorfer, M.
    Kollias, G.
    Aichinger, J.
    Winter, S.
    Nesser, H-J
    Martinek, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 : S45 - S46
  • [44] Atrial mapping and radiofrequency catheter ablation inpatients with idiopathic atrial fibrillation -: Electrophysiological findings and ablation results
    Gaita, F
    Riccardi, R
    Calò, L
    Scaglione, M
    Garberoglio, L
    Antolini, R
    Kirchner, M
    Lamberti, F
    Richiardi, E
    CIRCULATION, 1998, 97 (21) : 2136 - 2145
  • [45] Safety and efficacy of catheter ablation of atrial fibrillation using an irrigated-tip ablation catheter
    Vasamreddy, CR
    Jayam, V
    Lickfett, L
    Bradley, D
    Nasir, K
    Eldadah, Z
    Dickfeld, T
    Donahue, K
    Berger, R
    Calkins, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 114A - 114A
  • [46] Comparison of 28mm cryoballoon ablation versus radiofrequency catheter ablation of paroxysmal atrial fibrillation
    Kuhne, M.
    Suter, Y.
    Altmann, D.
    Schaer, B.
    Osswald, S.
    Sticherling, C.
    EUROPEAN HEART JOURNAL, 2010, 31 : 115 - 115
  • [47] Atrial fibrillation ablation with advanced radiofrequency catheter versus second-generation cryoballoon catheter
    Berman, Adam E.
    Maccioni, Sonia
    Khanna, Rahul
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2022, 11 (09) : 659 - 668
  • [48] A tailored approach to catheter ablation of paroxysmal atrial fibrillation
    Oral, H
    Chugh, A
    Good, E
    Sankaran, S
    Reich, SS
    Igic, P
    Elmouchi, D
    Tschopp, D
    Crawford, T
    Dey, S
    Wimmer, A
    Lemola, K
    Jongnarangsin, K
    Bogun, F
    Pelosi, F
    Morady, F
    CIRCULATION, 2006, 113 (15) : 1824 - 1831
  • [49] Radiation exposure on paroxysmal atrial fibrillation catheter ablation
    Scanavacca, M
    Samesima, N
    Caballero, J
    Sartini, R
    Diangelo, S
    Piza, F
    Hardy, C
    Sosa, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 131A - 131A
  • [50] Effect of Catheter Ablation on Progression of Paroxysmal Atrial Fibrillation
    Jongnarangsin, Krit
    Suwanagool, Arisara
    Chugh, Aman
    Crawford, Thomas
    Good, Eric
    Pelosi, Frank, Jr.
    Bogun, Frank
    Oral, Hakan
    Morady, Fred
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (01) : 9 - 14