Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: Verification of intracardiac signals with a second circular mapping catheter

被引:18
|
作者
Rosso, Raphael [1 ]
Halkin, Amir
Michowitz, Yoav
Belhassen, Bernard
Glick, Aharon
Viskin, Sami
机构
[1] Tel Aviv Sourasky Med Ctr, Dept Cardiol, IL-64239 Tel Aviv, Israel
关键词
Atrial fibrillation; Radiofrequency ablation; Pulmonary veins; PULMONARY VEIN POTENTIALS; PATIENT;
D O I
10.1016/j.hrthm.2013.12.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND During radiofrequency (RE) ablation of paroxysmal atrial fibrillation, a circular multielectrode recording "lasso" catheter is generally positioned within each pulmonary vein (PV) to determine when pulmonary vein potentials (PVPs) are present and when they have been ablated. The new irrigated multipolar nMARQ circular ablation catheter is positioned within the left atrium to create contiguous circular ablation lines around each PV ostium. OBJECTIVE To determine whether the recordings obtained from the nMARQ catheter position around the PV ostium accurately reproduce the recordings obtained from a Lasso catheter positioned within that vein. METHODS In 10 patients undergoing RF ablation of paroxysmaL atrial fibrillation, we placed an nMARQ and a lasso catheter around and within each PV, respectively. Recordings obtained from both catheters at baseline and after RE ablation were compared. RESULTS At baseline, recordings of PVPs in both catheters were concordant in 92% of all PVs. However, after RF delivery, the concordance between the nMARQ and lasso recordings was poor. The discordant result most commonly observed was disappearance of "PVPs" from the nMARQ catheter with persistence of PVPs in the Lasso catheter (12 of 39 [30%]). Conversely, the delivery of RE frequently resulted in fragmented electrograms (pseudo-PVPs) on the nMARQ catheter despite evidence of PV isolation by lasso catheter recordings. CONCLUSIONS The use of an nMARQ catheter alone, as currently recommended, may Lead to underestimation and overestimation of the number of RE applications required to achieve PV isolation.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [31] Toward radiofrequency catheter ablation of atrial fibrillation
    Haissaguerre, Michel
    HEART RHYTHM, 2021, 18 (12) : 2219 - 2220
  • [32] RADIOFREQUENCY CATHETER ABLATION FOR ATRIAL-FIBRILLATION
    HARVEY, MN
    MORADY, F
    CORONARY ARTERY DISEASE, 1995, 6 (02) : 115 - 120
  • [33] Percutaneous radiofrequency catheter ablation of atrial fibrillation
    Haegeli, Laurent M.
    EUROPEAN HEART JOURNAL, 2012, 33 (21) : 2625 - 2627
  • [34] New mapping tools for catheter ablation of atrial fibrillation
    Delgado-López M.
    Heeger C.-H.
    Tilz R.R.
    Herzschrittmachertherapie + Elektrophysiologie, 2022, 33 (4) : 380 - 385
  • [35] Pulmonary veins isolation for paroxysmal atrial fibrillation ablation without the use of circular mapping catheter
    Dourte, E.
    Robaye, B.
    Deceuninck, O.
    Dormal, F.
    Collet, B.
    Godeaux, V.
    Huys, F.
    Ballant, E.
    Gourdin, M.
    Blommaert, D.
    Xhaet, O.
    ACTA CARDIOLOGICA, 2020, 75 (06) : 589 - 590
  • [36] Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation
    Giuseppe Stabile
    Matteo Anselmino
    Ezio Soldati
    Ermengildo De Ruvo
    Francesco Solimene
    Assunta Iuliano
    Luigi Sciarra
    Maria Grazia Bongiorni
    Leonardo Calò
    Fiorenzo Gaita
    Journal of Interventional Cardiac Electrophysiology, 2017, 48 : 201 - 207
  • [37] Radiofrequency catheter ablation in atrial flutter and atrial fibrillation
    Reithmann, C
    Hoffmann, E
    Steinbeck, G
    HERZ, 1998, 23 (04) : 209 - 218
  • [38] Rapid Linear Ventricular Ablation Using a Novel Irrigated Multipolar Radiofrequency Ablation Catheter
    Nazer, Babak
    Walters, Tomos E.
    Duggirala, Srikant
    Gerstenfeld, Edward P.
    CIRCULATION, 2016, 134
  • [39] Risk factors of recurrence of paroxysmal atrial fibrillation after radiofrequency catheter ablation
    Zhang, X. L.
    Fu, H.
    Wei, X.
    Liang, Y. J.
    Tang, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 731 - 731
  • [40] Pulmonary vein isolation by radiofrequency ablation using an irrigated multipolar ablation catheter in the ostium
    Weiss, C
    Willems, S
    Franzen, O
    Rostock, T
    Skarda, JR
    Stewart, MT
    EUROPEAN HEART JOURNAL, 2002, 23 : 256 - 256