Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: Verification of intracardiac signals with a second circular mapping catheter

被引:18
|
作者
Rosso, Raphael [1 ]
Halkin, Amir
Michowitz, Yoav
Belhassen, Bernard
Glick, Aharon
Viskin, Sami
机构
[1] Tel Aviv Sourasky Med Ctr, Dept Cardiol, IL-64239 Tel Aviv, Israel
关键词
Atrial fibrillation; Radiofrequency ablation; Pulmonary veins; PULMONARY VEIN POTENTIALS; PATIENT;
D O I
10.1016/j.hrthm.2013.12.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND During radiofrequency (RE) ablation of paroxysmal atrial fibrillation, a circular multielectrode recording "lasso" catheter is generally positioned within each pulmonary vein (PV) to determine when pulmonary vein potentials (PVPs) are present and when they have been ablated. The new irrigated multipolar nMARQ circular ablation catheter is positioned within the left atrium to create contiguous circular ablation lines around each PV ostium. OBJECTIVE To determine whether the recordings obtained from the nMARQ catheter position around the PV ostium accurately reproduce the recordings obtained from a Lasso catheter positioned within that vein. METHODS In 10 patients undergoing RF ablation of paroxysmaL atrial fibrillation, we placed an nMARQ and a lasso catheter around and within each PV, respectively. Recordings obtained from both catheters at baseline and after RE ablation were compared. RESULTS At baseline, recordings of PVPs in both catheters were concordant in 92% of all PVs. However, after RF delivery, the concordance between the nMARQ and lasso recordings was poor. The discordant result most commonly observed was disappearance of "PVPs" from the nMARQ catheter with persistence of PVPs in the Lasso catheter (12 of 39 [30%]). Conversely, the delivery of RE frequently resulted in fragmented electrograms (pseudo-PVPs) on the nMARQ catheter despite evidence of PV isolation by lasso catheter recordings. CONCLUSIONS The use of an nMARQ catheter alone, as currently recommended, may Lead to underestimation and overestimation of the number of RE applications required to achieve PV isolation.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [21] Radiofrequency catheter ablation of vagotonic, adrenergic and random paroxysmal atrial fibrillation
    Oral, H
    Scharf, C
    Chugh, A
    Cheung, P
    Hall, B
    Veerareddy, S
    Pelosi, F
    Morady, F
    CIRCULATION, 2003, 108 (17) : 645 - 646
  • [22] Evaluation of an Optimized Workflow for the Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation
    Cui, Luqian
    Cui, Shihua
    Li, Jingchao
    Yu, Haijia
    Song, Huihui
    Chu, Yingjie
    Dong, Shujuan
    MEDICAL SCIENCE MONITOR, 2024, 30
  • [23] Ablation of right ventricular outflow tract tachycardia using a novel multipolar irrigated ablation catheter (nMARQ)
    Tuan, Jiun
    Andre Ng, G.
    HEART RHYTHM, 2014, 11 (03) : 502 - 505
  • [24] Unusefulness of image integration in radiofrequency catheter ablation of paroxysmal atrial fibrillation with multielectrode mapping systems
    Majocchi, B.
    Tundo, F.
    Fassini, G.
    Riva, S.
    Dello Russo, A.
    Casella, M.
    Moltrasio, M.
    Marino, V.
    Russo, E.
    Tondo, C.
    EUROPEAN HEART JOURNAL, 2014, 35 : 549 - 549
  • [25] Catheter ablation for paroxysmal and persistent atrial fibrillation
    Chen, Huai Sheng
    Wen, Jun Min
    Wu, Sheng Nan
    Liu, Jian Ping
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (04):
  • [26] Nonfluoroscopic catheter ablation of paroxysmal atrial fibrillation
    Lyan, Evgeny
    Tsyganov, Alexey
    Abdrahmanov, Ayan
    Morozov, Alexander
    Bakytzhanuly, Abay
    Tursunbekov, Azat
    Nuralinov, Omirbek
    Mironovich, Sergey
    Klukvin, Alexander
    Marinin, Valery
    Tilz, Roland Richard
    Sawan, Noureddin
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (06): : 611 - 619
  • [27] Remote Magnetic Navigation With Irrigated Tip Catheter for Ablation of Paroxysmal Atrial Fibrillation
    Miyazaki, Shinsuke
    Shah, Ashok J.
    Xhaet, Olivier
    Derval, Nicolas
    Matsuo, Seiichiro
    Wright, Matthew
    Nault, Isabelle
    Forclaz, Andrei
    Jadidi, Amir S.
    Knecht, Sebastien
    Rivard, Lena
    Liu, Xingpeng
    Linton, Nick
    Sacher, Frederic
    Hocini, Meleze
    Jais, Pierre
    Haissaguerre, Michel
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (06): : 585 - 589
  • [28] Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation
    Stabile, Giuseppe
    Anselmino, Matteo
    Soldati, Ezio
    De Ruvo, Ermengildo
    Solimene, Francesco
    Iuliano, Assunta
    Sciarra, Luigi
    Bongiorni, Maria Grazia
    Calo, Leonardo
    Gaita, Fiorenzo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 48 (02) : 201 - 207
  • [29] Radiofrequency catheter ablation of atrial flutter and fibrillation
    Saoudy, N
    Poty, H
    Cribier, AFA
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 337 - 339
  • [30] Radiofrequency catheter ablation of focal atrial fibrillation
    Peinado, RP
    Llorens, JLM
    Guindal, JAG
    Daza, JAS
    REVISTA ESPANOLA DE CARDIOLOGIA, 1998, 51 (06): : 494 - 497