Numerical investigations of the haemodynamic changes associated with stent malapposition in an idealised coronary artery

被引:25
|
作者
Poon, Eric K. W. [1 ]
Barlis, Peter [1 ,2 ]
Moore, Stephen [3 ]
Pan, Wei-Han [1 ]
Liu, Yun [1 ]
Ye, Yufei [1 ]
Xue, Yuan [1 ]
Zhu, Shuang J. [1 ]
Ooi, Andrew S. H. [1 ]
机构
[1] Univ Melbourne, Melbourne Sch Engn, Dept Mech Engn, Melbourne, Vic 3010, Australia
[2] Univ Melbourne, Melbourne Med Sch, North West Acad Ctr, Melbourne, Vic 3010, Australia
[3] Univ Melbourne, IBM Res Collaboratory Life Sci Melbourne, Victoria Life Sci Computat Initiat, Melbourne, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
Stent malapposition; Coronary stents; Atherosclerosis; in silico; Wall shear stress; SIROLIMUS-ELUTING STENT; INTRAVASCULAR ULTRASOUND ANALYSIS; ELEVATION MYOCARDIAL-INFARCTION; COMPUTATIONAL FLUID-DYNAMICS; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-FLOW-VELOCITY; BARE-METAL STENTS; SHEAR-STRESS; CIRCULAR-CYLINDER; IMPLANTATION;
D O I
10.1016/j.jbiomech.2014.07.030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The deployment of a coronary stent near complex lesions can sometimes lead to incomplete stent apposition (ISA), an undesirable side effect of coronary stent implantation. Three-dimensional computational fluid dynamics (CFD) calculations are performed on simplified stent models (with either square or circular cross-section struts) inside an idealised coronary artery to analyse the effect of different levels of ISA to the change in haemodynamics inside the artery. The clinical significance of ISA is reported using haemodynamic metrics like wall shear stress (WSS) and wall shear stress gradient (WSSG). A coronary stent with square cross-sectional strut shows different levels of reverse flow for malapposition distance (MD) between 0 mm and 0.12 mm. Chaotic blood flow is usually observed at late diastole and early systole for MD=0 mm and 0.12 mm but are suppressed for MD=0.06 mm. The struts with circular cross section delay the flow chaotic process as compared to square cross-sectional struts at the same MD and also reduce the level of fluctuations found in the flow field. However, further increase in MD can lead to chaotic flow not only at late diastole and early systole, but it also leads to chaotic flow at the end of systole. In all cases, WSS increases above the threshold value (0.5 Pa) as MD increases due to the diminishing reverse flow near the artery wall. Increasing MD also results in an elevated WSSG as flow becomes more chaotic, except for square struts at MD= 0.06 mm. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2843 / 2851
页数:9
相关论文
共 50 条
  • [21] Integrated analysis of gene expression changes associated with coronary artery disease
    Liu Miao
    Rui-Xing Yin
    Feng Huang
    Shuo Yang
    Wu-Xian Chen
    Jin-Zhen Wu
    Lipids in Health and Disease, 18
  • [22] Integrated analysis of gene expression changes associated with coronary artery disease
    Miao, Liu
    Yin, Rui-Xing
    Huang, Feng
    Yang, Shuo
    Chen, Wu-Xian
    Wu, Jin-Zhen
    LIPIDS IN HEALTH AND DISEASE, 2019, 18 (1)
  • [23] Proteomic Changes Associated with Cardiopulmonary Bypass for Coronary Artery Bypass Surgery
    De Biasio, Justin C.
    Shaefi, Shahzad
    Marcantonio, Edward
    Subramaniam, Balachundhar
    Shankar, Puja
    Libermann, Towia A.
    Dillon, Simon
    ANESTHESIA AND ANALGESIA, 2020, 130 : 164 - 165
  • [24] Numerical and experimental investigations of the flow-pressure relation in multiple sequential stenoses coronary artery
    Li, S.
    Chin, Cheng
    Thondapu, Vikas
    Poon, Eric K. W.
    Monty, Jason P.
    Li, Yingguang
    Ooi, Andrew S. H.
    Tu, Shengxian
    Barlis, Peter
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (07): : 1083 - 1088
  • [25] POSTEXERCISE CHANGES IN EJECTION FRACTION ASSOCIATED WITH CORONARY-ARTERY DISEASE
    LUTOLF, UM
    VANDYKE, DC
    BRISTOW, JD
    WEAVER, CS
    EUROPEAN JOURNAL OF CARDIOLOGY, 1980, 11 (04): : 283 - 294
  • [26] Numerical study on the mechanical coupling of external vascular stent and vein graft in coronary artery bypass surgery
    Gao R.
    Liang F.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2020, 37 (06): : 983 - 989
  • [27] Numerical analysis of stent expansion process in coronary artery stenosis with the use of non-compliant balloon
    Bukala, Jakub
    Kwiatkowski, Piotr
    Malachowski, Jerzy
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2016, 36 (01) : 145 - 156
  • [28] Continuous cardiac output monitoring during haemodynamic changes in off-pump coronary artery bypass grafting surgery
    Auler, J. O. C., Jr.
    Kim, S. M.
    Carmona, M. J. C.
    Malbouisson, L. M. S.
    de Oliveira, S. A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (10) : 890 - 892
  • [29] Serum Free Indoxyl Sulfate Associated with In-stent Restenosis After Coronary Artery Stentings
    Ming-Lung Tsai
    I-Chang Hsieh
    Cheng-Chieh Hung
    Chun-Chi Chen
    Cardiovascular Toxicology, 2015, 15 : 52 - 60
  • [30] Surgical management of drug-eluting stent associated coronary artery aneurysms: a case series
    Sajja, Lokeswara Rao
    Mannam, Gopichand
    Kamtam, Devanish Narasimhasanth
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 39 (02) : 182 - 185