Numerical investigations of the haemodynamic changes associated with stent malapposition in an idealised coronary artery

被引:25
|
作者
Poon, Eric K. W. [1 ]
Barlis, Peter [1 ,2 ]
Moore, Stephen [3 ]
Pan, Wei-Han [1 ]
Liu, Yun [1 ]
Ye, Yufei [1 ]
Xue, Yuan [1 ]
Zhu, Shuang J. [1 ]
Ooi, Andrew S. H. [1 ]
机构
[1] Univ Melbourne, Melbourne Sch Engn, Dept Mech Engn, Melbourne, Vic 3010, Australia
[2] Univ Melbourne, Melbourne Med Sch, North West Acad Ctr, Melbourne, Vic 3010, Australia
[3] Univ Melbourne, IBM Res Collaboratory Life Sci Melbourne, Victoria Life Sci Computat Initiat, Melbourne, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
Stent malapposition; Coronary stents; Atherosclerosis; in silico; Wall shear stress; SIROLIMUS-ELUTING STENT; INTRAVASCULAR ULTRASOUND ANALYSIS; ELEVATION MYOCARDIAL-INFARCTION; COMPUTATIONAL FLUID-DYNAMICS; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-FLOW-VELOCITY; BARE-METAL STENTS; SHEAR-STRESS; CIRCULAR-CYLINDER; IMPLANTATION;
D O I
10.1016/j.jbiomech.2014.07.030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The deployment of a coronary stent near complex lesions can sometimes lead to incomplete stent apposition (ISA), an undesirable side effect of coronary stent implantation. Three-dimensional computational fluid dynamics (CFD) calculations are performed on simplified stent models (with either square or circular cross-section struts) inside an idealised coronary artery to analyse the effect of different levels of ISA to the change in haemodynamics inside the artery. The clinical significance of ISA is reported using haemodynamic metrics like wall shear stress (WSS) and wall shear stress gradient (WSSG). A coronary stent with square cross-sectional strut shows different levels of reverse flow for malapposition distance (MD) between 0 mm and 0.12 mm. Chaotic blood flow is usually observed at late diastole and early systole for MD=0 mm and 0.12 mm but are suppressed for MD=0.06 mm. The struts with circular cross section delay the flow chaotic process as compared to square cross-sectional struts at the same MD and also reduce the level of fluctuations found in the flow field. However, further increase in MD can lead to chaotic flow not only at late diastole and early systole, but it also leads to chaotic flow at the end of systole. In all cases, WSS increases above the threshold value (0.5 Pa) as MD increases due to the diminishing reverse flow near the artery wall. Increasing MD also results in an elevated WSSG as flow becomes more chaotic, except for square struts at MD= 0.06 mm. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2843 / 2851
页数:9
相关论文
共 50 条
  • [31] Thrombotic occlusion of the coronary artery associated with accidental detachment of undeployed Palmaz-Schatz stent
    Shiojima, I
    Ikari, Y
    Abe, JI
    Ishizaka, N
    Maemura, K
    Kurihara, H
    Isshiki, TA
    Suma, H
    Saeki, H
    Hara, K
    Tamura, T
    Yamaguchi, T
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 38 (04): : 360 - 362
  • [32] Active matrix metalloproteinases 3 and 9 are independently associated with coronary artery in-stent restenosis
    Jones, G. T.
    Tarr, G. P.
    Phillips, L. V.
    Wilkins, G. T.
    van Rij, A. M.
    Williams, M. J. A.
    ATHEROSCLEROSIS, 2009, 207 (02) : 603 - 607
  • [33] Surgical management of drug-eluting stent associated coronary artery aneurysms: a case series
    Lokeswara Rao Sajja
    Gopichand Mannam
    Devanish Narasimhasanth Kamtam
    Indian Journal of Thoracic and Cardiovascular Surgery, 2023, 39 : 182 - 185
  • [34] Serum Free Indoxyl Sulfate Associated with In-stent Restenosis After Coronary Artery Stentings
    Tsai, Ming-Lung
    Hsieh, I-Chang
    Hung, Cheng-Chieh
    Chen, Chun-Chi
    CARDIOVASCULAR TOXICOLOGY, 2015, 15 (01) : 52 - 60
  • [35] IS CORONARY STENT IMPLANTATION ASSOCIATED WITH A HIGHER-RISK FOR CORONARY-ARTERY ANEURYSM FORMATION THAN BALLOON ANGIOPLASTY
    SLOTA, P
    FISCHMAN, D
    SAVAGE, M
    RAKE, R
    GOLDBERG, S
    CIRCULATION, 1995, 92 (08) : 3298 - 3298
  • [36] Use of the PK Papyrus Covered Coronary Stent in the Treatment of Kawasaki Disease-Associated Giant Coronary Artery Aneurysms
    Naimi, Iman
    Morray, Brian
    Steinberg, Zachary
    PEDIATRIC CARDIOLOGY, 2021, 42 (08) : 1909 - 1909
  • [37] ANGIOGRAPHIC CHANGES IN THE CORONARY-ARTERY ASSOCIATED WITH CYCLICAL REDUCTIONS OF CORONARY BLOOD-PRESSURE
    UCHIDA, Y
    YOSHIMOTO, N
    MURAO, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1980, 44 (03): : 163 - 171
  • [38] Use of the PK Papyrus covered coronary stent in the treatment of Kawasaki disease-associated giant coronary artery aneurysms
    Naimi, Iman
    Morray, Brian
    Portman, Michael A.
    Steinberg, Zachary L.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (07) : 1267 - 1272
  • [39] Intraluminal delivery of tyrosine kinase inhibitor with biodegradable stent suppresses the restenotic changes of the coronary artery in pigs
    Yamawaki, T
    Shimokawa, H
    Kozai, T
    Miyata, K
    Higo, T
    Tanaka, E
    Takeshita, A
    CIRCULATION, 1997, 96 (08) : 3395 - 3395
  • [40] Mechanical performances of balloon post-dilation for improving stent expansion in calcified coronary artery: Computational and experimental investigations
    Dong, Pengfei
    Mozafari, Hozhabr
    Lee, Juhwan
    Gharaibeh, Yazan
    Zimin, Vladislav N.
    Dallan, Luis A. P.
    Bezerra, Hiram G.
    Wilson, David L.
    Gu, Linxia
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 121