Numerical analysis of stent expansion process in coronary artery stenosis with the use of non-compliant balloon

被引:26
|
作者
Bukala, Jakub [1 ]
Kwiatkowski, Piotr [2 ]
Malachowski, Jerzy [1 ]
机构
[1] Mil Univ Technol, Dept Mech & Appl Comp Sci, Ul Gen Sylwestra,Kaliskiego 2, PL-00908 Warsaw, Poland
[2] Cent Clin Hosp, Minist Interior, Clin Dept Intervent Cardiol, Warsaw, Poland
关键词
Stent; Angioplasty; Coronary; Fea; Numerical; Balloon; FINITE-ELEMENT-ANALYSIS; DEFORMATION; RESTENOSIS; SIMULATION; TISSUE; VESSEL; IMPACT;
D O I
10.1016/j.bbe.2015.10.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the paper the authors present an applied methodology, data and numerical results for numerical analysis of the stent crimping process and stent implantation in the coronary artery stenosis with the use of a non-compliant angioplasty balloon. The authors focused on the modeling methodology of balloon angioplasty with minimum possible simplification, i.e.: a full load path (compression and inflation in single analysis), 3D unsymmetrical geometry and discretization, highly nonlinear material models (hyperelasticity, plastic kinematic formulation, crushable foam) and sophisticated contact models (bodies with highly different stiffness). The use of a highly compressible crushable foam material model for an arterial plaque is considered as the most original part of the work. The presented results allow for better understanding of the mechanisms governing stent crimping and implementation. (C) 2015 Published by Elsevier Sp. z o.o. on behalf of Nalecz Institute of Biocybemetics and Biomedical Engineering.
引用
收藏
页码:145 / 156
页数:12
相关论文
共 50 条
  • [1] Clinical Benefit of Use of Kissing Balloon Inflation and Non-Compliant Balloon in the Crush Technique for Bifurcation Coronary Lesions
    Kim, Young-Hak
    Lee, Jong-Young
    Kim, Youg-Giun
    Park, Gyun-Min
    Park, Duk-woo
    Kang, Soo-Jin
    Lee, Seung-Whan
    Lee, Cheol Whan
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B36 - B36
  • [2] Management and Retrieval of Undeflatable Non-Compliant Coronary Balloon During Percutaneous Coronary Intervention
    Yumul, Arvin Romero
    Yahaya, Shaiful Azmi
    Ganesan, Kumara Gurupparan
    Kolanthaivelu, Jayakhanthan
    Aris, Faten Aqilah
    Nazeeb, Mohamed Nazrul Mohamed
    Jalaluddin, Khin Maung Zan Mohd Saad
    Khaw, Chee Sin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (15) : S252 - S253
  • [3] Intravascular ultrasound evaluation of optimal drug-eluting stent expansion after post-stent balloon dilation using non-compliant balloon versus semi-compliant balloon. Post-stent optimal stent expansion trial (POET).
    Ko, Young-Guk
    Moon, Jae-Youn
    Choi, Donghoon
    Jang, Yangsoo
    Kang, Woong Chol
    Ahn, Taehoon
    Kim, Byoung-Keuk
    Oh, Soong Jin
    Jeon, Dong Woon
    Yang, Joo-Young
    CIRCULATION, 2006, 114 (18) : 548 - 548
  • [4] Unravelling of a Wiktor stent by a high pressure non-compliant balloon - Successful nonsurgical management
    Bhargava, B
    Agarwal, R
    Kaul, U
    JOURNAL OF INVASIVE CARDIOLOGY, 1996, 8 (09): : 447 - 449
  • [5] Stent Expansion after Additional Non-Compliant Balloon High Pressure Inflation in Patients with Drug-Eluting Stent Underexpansion: An Intravascular Ultrasound Study
    Lee, Wane Soo
    Kim, Sang Wook
    Mintz, Gary
    Hong, Young Joon
    Lee, Sung Yun
    Lee, Kwang Je
    Kim, Tae Ho
    Kim, Chee Jeong
    Ryu, Wang Seong
    Pichard, August
    Weissman, Neil
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (8A): : 72A - 72A
  • [6] Stent Expansion After Additional Non-Compliant Balloon High-Pressure Inflation in Patients With Drug-Eluting Stent Underexpansion: An Intravascular Ultrasound Study
    Kim, Sang-Wook
    Lee, Wang Soo
    Mintz, Gary S.
    Hong, Young Joon
    Lee, Sung Yun
    Lee, Kwang Je
    Kim, Tae Ho
    Kim, Chee Jeong
    Ryu, Wang Seong
    Pichard, August D.
    Weissman, Neil J.
    CIRCULATION, 2010, 122 (21)
  • [7] Stent Expansion After Additional Non-compliant Balloon High-pressure Inflation In Patients With Drug-eluting Stent Underexpansion: An Intravascular Ultrasound Study
    Kim, Sang-Wook
    Mintz, Gary S.
    Maehara, Akiko
    Lee, Ming Soo
    Hong, Young Joon
    Lee, Sung Yun
    Min, Yun Joo
    Lee, Kwang Je
    Kim, Tae Ho
    Kim, Chee Jeong
    Ryu, Wang Seong
    Weissman, Neil J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B60 - B60
  • [8] Coronary lithotripsy for failed rotational atherectomy, cutting balloon, scoring balloon, and ultra-high-pressure non-compliant balloon
    Venuti, Giuseppe
    D'Agosta, Guido
    Tamburino, Corrado
    La Manna, Alessio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 94 (03) : E111 - E115
  • [9] Impact of non-compliant balloon on long-term clinical outcomes in coronary bifurcation lesions: results from the COBIS (COronary BIfurcation Stent) II registry
    Park, T. K.
    Song, Y. B.
    Gwag, H. B.
    Jang, W. J.
    Yang, J. H.
    Hahn, J. Y.
    Choi, S. H.
    Choi, J. H.
    Lee, S. H.
    Gwon, H. C.
    EUROPEAN HEART JOURNAL, 2014, 35 : 466 - 466
  • [10] Combination of Laser Atherectomy and Super High-pressure Non-compliant Balloon to Treat Stent Under-expansion in Cases of Failed Interventional Options
    Sasi, Viktor
    Szanto, Gyula
    Achim, Alexandru
    Ungi, Imre
    Varga, Albert
    Ruzsa, Zoltan
    INTERVENTIONAL CARDIOLOGY-REVIEWS RESEARCH RESOURCES, 2023, 18