Numerical analysis of stent expansion process in coronary artery stenosis with the use of non-compliant balloon

被引:26
|
作者
Bukala, Jakub [1 ]
Kwiatkowski, Piotr [2 ]
Malachowski, Jerzy [1 ]
机构
[1] Mil Univ Technol, Dept Mech & Appl Comp Sci, Ul Gen Sylwestra,Kaliskiego 2, PL-00908 Warsaw, Poland
[2] Cent Clin Hosp, Minist Interior, Clin Dept Intervent Cardiol, Warsaw, Poland
关键词
Stent; Angioplasty; Coronary; Fea; Numerical; Balloon; FINITE-ELEMENT-ANALYSIS; DEFORMATION; RESTENOSIS; SIMULATION; TISSUE; VESSEL; IMPACT;
D O I
10.1016/j.bbe.2015.10.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the paper the authors present an applied methodology, data and numerical results for numerical analysis of the stent crimping process and stent implantation in the coronary artery stenosis with the use of a non-compliant angioplasty balloon. The authors focused on the modeling methodology of balloon angioplasty with minimum possible simplification, i.e.: a full load path (compression and inflation in single analysis), 3D unsymmetrical geometry and discretization, highly nonlinear material models (hyperelasticity, plastic kinematic formulation, crushable foam) and sophisticated contact models (bodies with highly different stiffness). The use of a highly compressible crushable foam material model for an arterial plaque is considered as the most original part of the work. The presented results allow for better understanding of the mechanisms governing stent crimping and implementation. (C) 2015 Published by Elsevier Sp. z o.o. on behalf of Nalecz Institute of Biocybemetics and Biomedical Engineering.
引用
收藏
页码:145 / 156
页数:12
相关论文
共 50 条
  • [31] Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation
    Yoshitaka Muraoka
    Shinjo Sonoda
    Yuki Tsuda
    Seiya Tanaka
    Masahiro Okazaki
    Yutaka Otsuji
    Heart and Vessels, 2011, 26 : 565 - 571
  • [32] Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation
    Muraoka, Yoshitaka
    Sonoda, Shinjo
    Tsuda, Yuki
    Tanaka, Seiya
    Okazaki, Masahiro
    Otsuji, Yutaka
    HEART AND VESSELS, 2011, 26 (06) : 565 - 571
  • [33] Catheter-based local antiproliferative therapy in kissing balloon technique for in-stent stenosis of coronary artery bifurcation lesions
    Herdeg, Christian
    Ceisler, Tobias
    Goehring-Frischholz, Katrin
    Zuern, Christine
    Hartmann, Ulrike
    Haase, Karl K.
    Gawaz, Meinrad
    CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (04) : 309 - 311
  • [34] An analysis of published cases of cutting balloon use in spontaneous coronary artery dissection
    Maricic, Bojan
    Perisic, Zoran
    Kostic, Tomislav
    Bozinovic, Nenad
    Petrovic, Milovan
    Cankovic, Milenko
    Mehmedbegovic, Zlatko
    Juricic, Stefan
    Vasilev, Vladimir
    Dakic, Sonja
    Perisic, Jelena
    Milosevic, Jelena
    Bojanovic, Mihajlo
    Nikolic, Miroslav
    Maricic, Tijana
    Apostolovic, Svetlana
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [35] The impact of post-dilatation on stent expansion and eccentricity using the novel balloon delivery system for the self-apposing coronary artery stent; a detailed Optical Coherence Tomography analysis
    Lu, Huangling
    IJsselmuiden, Alexander J.
    Grundeken, Maik J.
    Nassif, Martina
    de Vries, Arie G.
    Weevers, Auke
    Scholte, Martijn
    Spaargaren, Rene
    Wykrzykowska, Joanna J.
    Tijssen, Jan G.
    de Winter, Robbert J.
    Koch, Karel T.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B140 - B140
  • [36] Intravascular ultrasound analysis of the effect of post-dilation with non-compliant balloons following initial high pressure stent implantation using newer generation stent delivery systems
    Patel, T
    Cutlip, DE
    Cove, CJ
    Pomerantz, RM
    Ling, FS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 45A - 45A
  • [37] Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience
    Salsamendi, Jason
    Pereira, Keith
    Baker, Reginald
    Bhatia, Shivank S.
    Narayanan, Govindarajan
    JOURNAL OF RADIOLOGY CASE REPORTS, 2015, 9 (10): : 9 - 17
  • [38] CLINICAL CHARACTERISTICS OF PATENTS WHO DEVELOPED SLOW FLOW/ NO-REFLOW AFTER POST-DILATATION WITH NON-COMPLIANT BALLOON DURING PRIMARY PERCUTANEOUS CORONARY INTERVENTION
    Parkash, Chandar
    Mal, Vashu
    Shaikh, Asim
    Kumar, Dileep
    Ahmed, Rameez
    Masood, Sara
    Shah, Jehanghir Ali
    Ahmed, Bashir
    Khan, Naveedullah
    Sial, Jawaid Akbar
    PAKISTAN HEART JOURNAL, 2023, 56 (01): : 110 - 114
  • [39] Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening
    Ganesh B. Rahinj
    Harshit S. Chauhan
    Martin L. Sirivella
    Menta V. Satyanarayana
    Laxminarayanan Ramanan
    Cardiovascular Engineering and Technology, 2022, 13 : 247 - 264
  • [40] Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening
    Rahinj, Ganesh B.
    Chauhan, Harshit S.
    Sirivella, Martin L.
    Satyanarayana, Menta, V
    Ramanan, Laxminarayanan
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2022, 13 (02) : 247 - 264