A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA

被引:22
|
作者
Alhazmi, Abdulaziz [1 ]
Gianoli, Chiara [1 ]
Neppl, Sebastian [2 ]
Martins, Juliana [1 ]
Veloza, Stella [1 ]
Podesta, Mark [3 ]
Verhaegen, Frank [3 ]
Reiner, Michael [2 ]
Belka, Claus [2 ]
Parodi, Katia [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Munich, Germany
[2] Univ Hosp, Dept Radiat Oncol, LMU Munich, Munich, Germany
[3] Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Med Ctr, Maastricht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 11期
关键词
EPID dosimetry; pre-treatment QA; dose reconstruction; VMAT; IMRT; 2D DIODE-ARRAY; QUALITY-ASSURANCE; VERIFICATION; POSITION; MODE; FILM;
D O I
10.1088/1361-6560/aac1a6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are relatively complex treatment delivery techniques and require quality assurance (QA) procedures. Pre-treatment dosimetric verification represents a fundamental QA procedure in daily clinical routine in radiation therapy. The purpose of this study is to develop an EPID-based approach to reconstruct a 3D dose distribution as imparted to a virtual cylindrical water phantom to be used for plan-specific pre-treatment dosimetric verification for IMRT and VMAT plans. For each depth, the planar 2D dose distributions acquired in air were back-projected and convolved by depth-specific scatter and attenuation kernels. The kernels were obtained by making use of scatter and attenuation models to iteratively estimate the parameters from a set of reference measurements. The derived parameters served as a look-up table for reconstruction of arbitrary measurements. The summation of the reconstructed 3D dose distributions resulted in the integrated 3D dose distribution of the treatment delivery. The accuracy of the proposed approach was validated in clinical IMRT and VMAT plans by means of gamma evaluation, comparing the reconstructed 3D dose distributions with Octavius measurement. The comparison was carried out using (3% , 3 mm) criteria scoring 99% and 96% passing rates for IMRT and VMAT, respectively. An accuracy comparable to the one of the commercial device for 3D volumetric dosimetry was demonstrated. In addition, five IMRT and five VMAT were validated against the 3D dose calculation performed by the TPS in a water phantom using the same passing rate criteria. The median passing rates within the ten treatment plans was 97.3%, whereas the lowest was 95%. Besides, the reconstructed 3D distribution is obtained without predictions relying on forward dose calculation and without external phantom or dosimetric devices. Thus, the approach provides a fully automated, fast and easy QA procedure for plan-specific pretreatment dosimetric verification.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] EPID-Based in Vivo Dosimetry: The Next Step in Patient-Specific QA
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Mans, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [32] On the Sensitivity of An EPID-Based 3D Dose Verification System to Detect Delivery Errors in VMAT Treatments
    Gonzalez, P.
    Olaciregui-Ruiz, I.
    Mijnheer, B.
    Mans, A.
    Rozendaal, R.
    MEDICAL PHYSICS, 2016, 43 (06) : 3633 - 3633
  • [33] DEVELOPMENT OF AN A-SI EPID-BASED SYSTEM FOR MACHINE, IMRT AND VMAT QUALITY ASSURANCE
    Vazquez-Quino, L. A.
    Chen, X.
    Fitzpatrick, M.
    Shi, C.
    Mavroidis, P.
    Alkhatib, H.
    Mihailidis, D.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S170 - S171
  • [34] Investigating the effectiveness of monitoring relevant variations during IMRT and VMAT treatments by EPID-based 3D in vivo verification performed using planning CTs
    Li, Yinghui
    Zhu, Jinhan
    Shi, Jinping
    Chen, Lixin
    Liu, Xiaowei
    PLOS ONE, 2019, 14 (06):
  • [35] On using 3D γ-analysis for IMRT and VMAT pretreatment plan QA
    Wu, Chuan
    Hosier, Kelly E.
    Beck, Kristen E.
    Radevic, Marlyn B.
    Lehmann, Joerg
    Zhang, Hao H.
    Kroner, Aaron
    Dutton, Sharon C.
    Rosenthal, Seth A.
    Bareng, Jonathan K.
    Logsdon, Mark D.
    Asche, David R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3051 - 3059
  • [36] EPID-based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams
    Miri, Narges
    Keller, Peter
    Zwan, Benjamin J.
    Greer, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 292 - 304
  • [37] Clinical results of an EPID-based in-vivo dosimetry for prostate cancer treated by VMAT
    Falco, M. D.
    Giancaterino, S.
    De Nicola, A.
    Perrotti, F.
    Menna, S.
    Fidanzio, A.
    Piermattei, A.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S706 - S706
  • [38] 3D EPID based dosimetry for pre-treatment verification of VMAT - methods and challenges
    Greer, P. B.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [39] In vivo EPID dosimetry: 3D analysis applied to prostate VMAT treatments
    Villaggi, E.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S217 - S218
  • [40] Initial clinical experience with EPID-based in-vivo dosimetry for VMAT treatment verification
    Cilla, S.
    Meluccio, D.
    Fidanzio, A.
    Azario, L.
    Greco, F.
    Deodato, F.
    Macchia, G.
    Digesu, C.
    Valentini, V.
    Morganti, A. G.
    Piermattei, A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S852 - S852