A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA

被引:21
|
作者
Alhazmi, Abdulaziz [1 ]
Gianoli, Chiara [1 ]
Neppl, Sebastian [2 ]
Martins, Juliana [1 ]
Veloza, Stella [1 ]
Podesta, Mark [3 ]
Verhaegen, Frank [3 ]
Reiner, Michael [2 ]
Belka, Claus [2 ]
Parodi, Katia [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Munich, Germany
[2] Univ Hosp, Dept Radiat Oncol, LMU Munich, Munich, Germany
[3] Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Med Ctr, Maastricht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 11期
关键词
EPID dosimetry; pre-treatment QA; dose reconstruction; VMAT; IMRT; 2D DIODE-ARRAY; QUALITY-ASSURANCE; VERIFICATION; POSITION; MODE; FILM;
D O I
10.1088/1361-6560/aac1a6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are relatively complex treatment delivery techniques and require quality assurance (QA) procedures. Pre-treatment dosimetric verification represents a fundamental QA procedure in daily clinical routine in radiation therapy. The purpose of this study is to develop an EPID-based approach to reconstruct a 3D dose distribution as imparted to a virtual cylindrical water phantom to be used for plan-specific pre-treatment dosimetric verification for IMRT and VMAT plans. For each depth, the planar 2D dose distributions acquired in air were back-projected and convolved by depth-specific scatter and attenuation kernels. The kernels were obtained by making use of scatter and attenuation models to iteratively estimate the parameters from a set of reference measurements. The derived parameters served as a look-up table for reconstruction of arbitrary measurements. The summation of the reconstructed 3D dose distributions resulted in the integrated 3D dose distribution of the treatment delivery. The accuracy of the proposed approach was validated in clinical IMRT and VMAT plans by means of gamma evaluation, comparing the reconstructed 3D dose distributions with Octavius measurement. The comparison was carried out using (3% , 3 mm) criteria scoring 99% and 96% passing rates for IMRT and VMAT, respectively. An accuracy comparable to the one of the commercial device for 3D volumetric dosimetry was demonstrated. In addition, five IMRT and five VMAT were validated against the 3D dose calculation performed by the TPS in a water phantom using the same passing rate criteria. The median passing rates within the ten treatment plans was 97.3%, whereas the lowest was 95%. Besides, the reconstructed 3D distribution is obtained without predictions relying on forward dose calculation and without external phantom or dosimetric devices. Thus, the approach provides a fully automated, fast and easy QA procedure for plan-specific pretreatment dosimetric verification.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] 3D EPID-based in vivo dosimetry for IMRT and VMAT
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Vijlbrief, R.
    Mans, A.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [2] A Novel EPID-Based 3D Dose Reconstruction for IMRT QA
    Alhazmi, A.
    Gianoli, C.
    Neppl, S.
    Veloza, S.
    Martins, J.
    Podesta, M.
    Verhaegen, F.
    Reiner, M.
    Belka, C.
    Parodi, K.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2887 - 2887
  • [3] Sensitivity analysis of EPID-based 3D dose reconstruction for VMAT QA
    Alhazmi, A.
    Gianoli, C.
    Neppl, S.
    Martins, J.
    Veloza, S.
    Podesta, M.
    Verhaegen, F.
    Reiner, M.
    Belka, C.
    Parodi, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S960 - S961
  • [4] A Viable Approach to Patient Specific QA for Spine VMAT SRS Using EPID-Based Dosimetry
    Song, Y.
    Zhang, P.
    Li, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3742 - 3742
  • [5] Implementing an EPID Based 3D Absolute Dosimetry System for IMRT QA
    Patel, J. B.
    Bismack, B. J.
    Parsai, E. I.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S746 - S746
  • [6] Error detection during VMAT delivery using EPID-based 3D transit dosimetry
    Mijnheer, B.
    Jomehzadeh, A.
    Gonzalez, P.
    Olaciregui-Ruiz, I
    Rozendaal, R.
    Shokrani, P.
    Spreeuw, H.
    Tielenburg, R.
    Mans, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 : 137 - 145
  • [7] Establishing action levels for EPID-based QA for IMRT
    Howell, Rebecca M.
    Smith, Iris P. N.
    Jarrio, Christie S.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 16 - 25
  • [8] Development of an EPID-Based Machine and IMRT QA System
    Chen, X.
    Shi, C.
    Buckey, C.
    Stathakis, S.
    Alkhatib, H.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3154 - +
  • [9] Sensing ability of EPID-based in vivo dosimetry for VMAT
    Tanooka, M.
    Tarutani, K.
    Doi, H.
    Suzuki, H.
    Takada, Y.
    Fujiwara, M.
    Toda, Y.
    Fujimoto, H.
    Miyashita, M.
    Okumura, A.
    Kagawa, K.
    Kamikonya, N.
    Yamakado, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S939 - S940
  • [10] EPID-based verification of the MLC performance for dynamic IMRT and VMAT
    Rowshanfarzad, Pejman
    Sabet, Mahsheed
    Barnes, Michael P.
    O'Connor, Daryl J.
    Greer, Peter B.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6192 - 6207