Binary pseudorandom test standard to determine the modulation transfer function of optical microscopes

被引:0
|
作者
Lacey, Ian [1 ]
Anderson, Erik H. [1 ]
Artemiev, Nikolay A. [1 ]
Babin, Sergey [2 ]
Cabrini, Stefano [1 ]
Calafiore, Guiseppe [2 ]
Chan, Elaine R. [1 ]
McKinney, Wayne R. [1 ]
Peroz, Christophe [2 ]
Takacs, Peter Z. [3 ]
Yashchuk, Valeriy V. [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[2] ABeam Technol Inc, Hayward, CA 94541 USA
[3] Brookhaven Natl Lab, Upton, NY 11973 USA
关键词
modulation transfer function; interferometric microscope; coded aperture imaging; calibration; test standard; correlation analysis; surface metrology; systematic error; ARRAYS;
D O I
10.1117/12.2185191
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This work reports on the development of a binary pseudo-random test sample optimized to calibrate the MTF of optical microscopes. The sample consists of a number of 1-D and 2-D patterns, with different minimum sizes of spatial artifacts from 300 nm to 2 microns. We describe the mathematical background, fabrication process, data acquisition and analysis procedure to return spatial frequency based instrument calibration. We show that the developed samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Evaluation of Geometrical Modulation Transfer Function in Optical Lens System
    Tsai, Cheng-Mu
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2015, 2015
  • [22] Evaluation of Modulation Transfer Function on the Optical Tomography Imaging System
    Wang, Yicheng
    Li, Baosheng
    2015 8TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), 2015, : 717 - 721
  • [23] A formula for the mean human optical modulation transfer function as a function of pupil size
    Watson, Andrew B.
    JOURNAL OF VISION, 2013, 13 (06): : 18
  • [24] Can processed images be used to determine the modulation transfer function and detective quantum efficiency?
    Garland, Lisa M.
    Yang, Haechan J.
    Picot, Paul A.
    Tanguay, Jesse
    Cunningham, Ian A.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (03)
  • [25] Signal processing and correction implementation for modulation transfer function test bench
    Chen, Yuheng
    Chen, Xinhua
    Xiang, Chunchang
    Shen, Weimin
    OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY, 2010, 7850
  • [26] Test method of the dynamic modulation transfer function in an indoor analog environment
    Zhang W.
    Yu X.
    Han F.
    Zhang F.
    Wu Y.
    Chen Y.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (07):
  • [27] Modulation transfer function measurement of sampled imaging systems in field test
    Yang Le
    Sun Qiang
    Wang Jian
    Zhang Jianzhong
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656
  • [28] OPTICAL CRITERIA FOR THE PREDICTION OF OPTICAL-SYSTEM MODULATION TRANSFER-FUNCTION (MTF)
    FEHNIGER, MJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 310 : 70 - 76
  • [29] Average optical modulation transfer function of the human eye in a normal population as a function of age
    Guirao, A
    Redondo, M
    Gonzalez, C
    Geragthy, E
    Norrby, S
    Artal, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4722 - 4722
  • [30] Imaging performance evaluation for fiber optical plates with Modulation Transfer Function
    Tian, WJ
    Zhang, W
    Ma, WH
    Wang, YX
    Li, WL
    OPTICAL DESIGN AND TESTING, 2002, 4927 : 193 - 198