Refrigerant maldistribution in an evaporator of automotive air conditioning system: investigation and a design improvement by numerical simulations

被引:0
|
作者
Stevanovic, V. [1 ]
Cucuz, S. [1 ]
Seeds, N. [1 ]
机构
[1] Univ Belgrade, Fac Mech Engn, Belgrade 11001, Serbia
关键词
2-PHASE FLOW DISTRIBUTION; ANNULAR-FLOW; HEADER;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Temperature stratification in the exit stream of cooled air from the plate and fin evaporator in automotive air conditioning occurs under low operating loads. Numerical simulations and analyses show that this malfunction is caused by the uneven distribution of the refrigerant liquid from the two-phase mixture in the header towards the evaporating channel. The applied numerical approach is validated for available experimental conditions. Refrigerant two-phase flows in a header of improved design are numerically investigated and a reduction of the temperature stratification is demonstrated.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 50 条
  • [1] A numerical investigation of the refrigerant maldistribution from a header towards parallel channels in an evaporator of automotive air conditioning system
    Stevanovic, Vladimir
    Cucuz, Stojan
    Carl-Meissner, Waldemar
    Maslovaric, Blazenka
    Prica, Sanja
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (13-14) : 3335 - 3343
  • [2] Sleeping evaporator and refrigerant maldistribution: An experimental investigation in an automotive multi-evaporator air-conditioning and battery cooling system
    Gillet, Thomas
    Andres, Emmanuelle
    El-Bakkali, Amin
    Lemort, Vincent
    Rulliere, Romuald
    Haberschill, Philippe
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 90 : 119 - 131
  • [3] Experimental study on refrigerant maldistribution in a fin-and-tube evaporator for a direct expansion air-conditioning system
    Tang, Haida
    Zhang, Tao
    Liu, Xiao-Hua
    [J]. ENERGY AND BUILDINGS, 2020, 208
  • [4] AN EXPERIMENTAL INVESTIGATION OF THE EFFECT OF REFRIGERANT CHARGE LEVEL ON AN AUTOMOTIVE AIR CONDITIONING SYSTEM
    Atik, Kemal
    Aktas, Abdurrazzak
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2011, 31 (01) : 11 - 17
  • [5] ANALYSIS OF THE PERFORMANCE OF THE EVAPORATOR OF AUTOMOTIVE AIR CONDITIONING SYSTEM
    Shen, C. C.
    Lu, J. H.
    [J]. INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2014, 15 (01) : 19 - 38
  • [6] Analysis of the performance of the evaporator of automotive air conditioning system
    C. C. Shen
    J. H. Lu
    [J]. International Journal of Automotive Technology, 2014, 15 : 19 - 38
  • [7] Tribology of an automotive air conditioning system with an alternative refrigerant
    Natsume, Yoshitaka
    Arahira, Kazuharu
    [J]. Toraibarojisuto/Journal of Japanese Society of Tribologists, 40 (09):
  • [8] THE TRIBOLOGY OF AN AUTOMOTIVE AIR-CONDITIONING SYSTEM WITH AN ALTERNATIVE REFRIGERANT
    NATSUME, Y
    ARAHIRA, K
    [J]. JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS, 1995, 40 (09) : 718 - 723
  • [9] Airflow maldistribution and the performance of a packaged air conditioning unit evaporator
    Aganda, AA
    Coney, JER
    Sheppard, CGW
    [J]. APPLIED THERMAL ENGINEERING, 2000, 20 (06) : 515 - 528
  • [10] Numerical analysis of evaporator frosting in automotive air-conditioning system with a variable-displacement compressor
    Tian, CQ
    Li, XT
    Yang, XJ
    [J]. APPLIED ENERGY, 2005, 82 (01) : 1 - 22