Refrigerant maldistribution in an evaporator of automotive air conditioning system: investigation and a design improvement by numerical simulations

被引:0
|
作者
Stevanovic, V. [1 ]
Cucuz, S. [1 ]
Seeds, N. [1 ]
机构
[1] Univ Belgrade, Fac Mech Engn, Belgrade 11001, Serbia
关键词
2-PHASE FLOW DISTRIBUTION; ANNULAR-FLOW; HEADER;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Temperature stratification in the exit stream of cooled air from the plate and fin evaporator in automotive air conditioning occurs under low operating loads. Numerical simulations and analyses show that this malfunction is caused by the uneven distribution of the refrigerant liquid from the two-phase mixture in the header towards the evaporating channel. The applied numerical approach is validated for available experimental conditions. Refrigerant two-phase flows in a header of improved design are numerically investigated and a reduction of the temperature stratification is demonstrated.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 50 条
  • [41] Numerical simulation on performance band of automotive air conditioning system with a variable displacement compressor
    Tian, CQ
    Li, XT
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (17) : 2718 - 2738
  • [42] Design and parametric investigation of an ejector in an air-conditioning system
    Rogdakis, ED
    Alexis, GK
    [J]. APPLIED THERMAL ENGINEERING, 2000, 20 (02) : 213 - 226
  • [43] Performance investigation on refrigeration and air conditioning systems with multi-evaporator
    Liu, Haibo
    Ma, Guoyuan
    Shao, Shuangquan
    Fan, Boyuan
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2018, 39 : 605 - 612
  • [44] The optimal design of refrigerant mixtures for a two-evaporator refrigeration system
    Churi, N
    Achenie, LEK
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 1997, 21 : S349 - S354
  • [45] Distributed control for a multi-evaporator air conditioning system
    Mei, Jun
    Xia, Xiaohua
    [J]. CONTROL ENGINEERING PRACTICE, 2019, 90 : 85 - 100
  • [46] Second law analysis of an automotive air conditioning system using HFO-1234yf, an environmentally friendly refrigerant
    Golzari, Soudabeh
    Kasaeian, Alibakhsh
    Daviran, Samaneh
    Mahian, Omid
    Wongwises, Somchai
    Sahin, Ahmet Z.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 73 : 134 - 143
  • [47] Numerical investigation of the effect of microchannel evaporator design and operation on the improvement potential of ejector refrigeration cycles
    Lawrence, Neal
    Elbel, Stefan
    [J]. ENERGY, 2018, 164 : 21 - 34
  • [48] Thermodynamic Investigation of Automotive Air Conditioning System Performance Using Ejector as an Expansion Device
    Sumeru, Kasni
    Pratikto
    Tritjahjono, Rachmad Imbang
    Sukri, Mohamad Firdaus
    [J]. INNOVATIVE SCIENCE AND TECHNOLOGY IN MECHANICAL ENGINEERING FOR INDUSTRY 4.0, 2019, 2187
  • [49] Numerical Investigation into the Air Flow Distributions of the Air Conditioning System in the Modular Data Center
    Dong, Hao
    Qin, Ziqiang
    Liu, Shicheng
    Li, Yao
    Shen, Yingying
    Wang, Haibo
    Zong, Yitong
    Wu, Xiaojun
    Si, Haiqing
    [J]. ADVANCES IN APPLIED MATHEMATICS AND MECHANICS, 2019, 11 (01) : 91 - 107
  • [50] Coupled effect of operation conditions and refrigerant charge on the performance of a transcritical CO2 automotive air conditioning system
    Yin, Xiang
    Wang, Anci
    Fang, Jianmin
    Cao, Feng
    Wang, Xiaolin
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 123 : 72 - 80