Refrigerant maldistribution in an evaporator of automotive air conditioning system: investigation and a design improvement by numerical simulations

被引:0
|
作者
Stevanovic, V. [1 ]
Cucuz, S. [1 ]
Seeds, N. [1 ]
机构
[1] Univ Belgrade, Fac Mech Engn, Belgrade 11001, Serbia
关键词
2-PHASE FLOW DISTRIBUTION; ANNULAR-FLOW; HEADER;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Temperature stratification in the exit stream of cooled air from the plate and fin evaporator in automotive air conditioning occurs under low operating loads. Numerical simulations and analyses show that this malfunction is caused by the uneven distribution of the refrigerant liquid from the two-phase mixture in the header towards the evaporating channel. The applied numerical approach is validated for available experimental conditions. Refrigerant two-phase flows in a header of improved design are numerically investigated and a reduction of the temperature stratification is demonstrated.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 50 条
  • [21] Development of durability test bench and experimental evaluation for refrigerant compressor of automotive air conditioning system
    Department of Mechanical Engineering, Cheng Shiu University, Cheng-Ching RD., Niaosong Township, Kaohsiung County 833, Taiwan
    [J]. Key Engineering Materials, 2008, 381-382 : 489 - 492
  • [22] Experimental study on performance of automotive air conditioning system using R-152a refrigerant
    Yoo, S. -Y.
    Lee, D. -W.
    [J]. INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2009, 10 (03) : 313 - 320
  • [23] Investigation of Optimum Refrigerant Charge and Fans' Speed for a Vehicle Air Conditioning System
    Bagheri, Farshid
    Fayazbakhsh, M. Ali
    Bahrami, Majid
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2017, 9 (01)
  • [24] Generic simulation model of multi-evaporator variable refrigerant flow air conditioning system for control analysis
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fan, Bo
    Fu, Sijie
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (06): : 1602 - 1615
  • [25] A modeling study on the effects of refrigerant pipeline length on the operational performance of a dual-evaporator air conditioning system
    Pan Yan
    Xu Xiangguo
    Xia Liang
    Deng Shiming
    [J]. APPLIED THERMAL ENGINEERING, 2012, 39 : 15 - 25
  • [26] Composite nanolubricants in automotive air conditioning system: An investigation on its performance
    Zawawi, N. N. M.
    Azmi, W. H.
    Sharif, M. Z.
    Shaiful, A. I. M.
    [J]. 1ST INTERNATIONAL POSTGRADUATE CONFERENCE ON MECHANICAL ENGINEERING (IPCME2018), 2019, 469
  • [27] Study of compressor-performance improvement in automotive air-conditioning system
    Kim, Young Shin
    Yoo, Seong Yeon
    Na, Seung Gyu
    [J]. Transactions of the Korean Society of Mechanical Engineers, B, 2015, 39 (09) : 713 - 718
  • [28] Performance evaluation of ecofriendly R1234ze(E) refrigerant in an automotive air conditioning system
    Kuwar, Yogendra V.
    [J]. HEAT TRANSFER, 2024, 53 (02) : 472 - 494
  • [29] Experimental study on automotive cooling and heating air conditioning system using CO2 as a refrigerant
    Tamura, T
    Yakumaru, Y
    Nishiwaki, F
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08): : 1302 - 1307