A simple approach to X-ray spectrometry with driftless gas proportional scintillation counters

被引:0
|
作者
Simoes, PCPS [1 ]
Covita, DS [1 ]
Monteiro, CMB [1 ]
dos Santos, JMF [1 ]
Morgado, RE [1 ]
机构
[1] Univ Coimbra, Dept Phys, P-3004516 Coimbra, Portugal
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Driftless gas proportional scintillation counters are used not only for soft x-ray spectrometry but also for x-rays with energies in the 0.1- to 25-keV region. At the higher energies, however, pulse amplitudes will depend on where the absorption occurred in the detector. Pulse-shape analysis with either analog or digital pulse techniques is required to restore proportionality between the measured pulse and the energy of the x-ray. In this work we describe a simpler approach to driftless gas proportional scintillation counter spectrometry at higher energies. The method eliminates the requirement for additional analog electronics or digital signal processing with only a modest amount of energy-dependent degradation in overall performance. The approach relies on short amplifier time constants and allows tradeoffs in the design of x-ray spectrometers whose performance requirements do not justify the complexity of a fully compensated system. We report the results of a comprehensive study of the performance characteristics of a driftless GPSC using short time constants with no additional compensation and compare its performance with that of a fully compensated digital system as a function of x-ray energy.
引用
收藏
页码:289 / 293
页数:5
相关论文
共 50 条
  • [41] μ-Strip photosensors for gas proportional scintillation counters
    Veloso, JFCA
    Freitas, DSAP
    dos Santos, JMF
    Morgado, RE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 223 - 227
  • [42] PEAK SHIFTS IN GAS PROPORTIONAL SCINTILLATION COUNTERS
    ALVES, MAF
    POLICARPO, AJ
    DOSSANTO.MC
    NUCLEAR INSTRUMENTS & METHODS, 1973, 111 (03): : 413 - 418
  • [43] OPERATING LIFE OF X-RAY PROPORTIONAL-COUNTERS
    VAIGACHEV, AA
    KLUKVINA, EF
    PUZYREV, SY
    SOROKIN, LS
    CHAIKOVSKII, VG
    SHCHEKIN, KI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1977, 20 (04) : 1014 - 1015
  • [44] DETECTION AND CORRECTION OF NONLINEARITY IN X-RAY PROPORTIONAL COUNTERS
    SHORT, MA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (06): : 618 - 620
  • [45] BACKGROUND IN X-RAY ASTRONOMY PROPORTIONAL-COUNTERS
    BOWER, CR
    DIETZ, KL
    RAMSEY, BD
    WEISSKOPF, MC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 585 - 590
  • [46] SUPPORT OF THIN WINDOWS FOR X-RAY PROPORTIONAL COUNTERS
    SHEATHER, PH
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (04): : 319 - 322
  • [47] PRINCIPLES AND APPLICATIONS OF PROPORTIONAL COUNTERS FOR X-RAY SPECTROGRAPHS
    BESSEN, II
    SPECTROCHIMICA ACTA, 1958, 10 (03): : 339 - 339
  • [48] ADVANCES IN DESIGN AND PERFORMANCE OF X-RAY PROPORTIONAL COUNTERS
    CULHANE, JL
    HERRING, J
    SANFORD, PW
    OSHEA, G
    PHILLIPS, RD
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (12): : 908 - &
  • [49] MICROSTRIP PROPORTIONAL-COUNTERS FOR X-RAY ASTRONOMY
    BUDTZJORGENSEN, C
    BAHNSEN, A
    OLESEN, C
    MADSEN, MM
    JONASSON, P
    SCHNOPPER, HW
    OED, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 82 - 87
  • [50] RECENT PROGRESS IN DEVELOPMENT OF A GAS SCINTILLATION PROPORTIONAL COUNTER FOR X-RAY ASTRONOMY
    ANDRESEN, RD
    LEIMANN, EA
    PEACOCK, A
    TAYLOR, BG
    BROWNLIE, G
    SANFORD, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 810 - 816