A simple approach to X-ray spectrometry with driftless gas proportional scintillation counters

被引:0
|
作者
Simoes, PCPS [1 ]
Covita, DS [1 ]
Monteiro, CMB [1 ]
dos Santos, JMF [1 ]
Morgado, RE [1 ]
机构
[1] Univ Coimbra, Dept Phys, P-3004516 Coimbra, Portugal
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Driftless gas proportional scintillation counters are used not only for soft x-ray spectrometry but also for x-rays with energies in the 0.1- to 25-keV region. At the higher energies, however, pulse amplitudes will depend on where the absorption occurred in the detector. Pulse-shape analysis with either analog or digital pulse techniques is required to restore proportionality between the measured pulse and the energy of the x-ray. In this work we describe a simpler approach to driftless gas proportional scintillation counter spectrometry at higher energies. The method eliminates the requirement for additional analog electronics or digital signal processing with only a modest amount of energy-dependent degradation in overall performance. The approach relies on short amplifier time constants and allows tradeoffs in the design of x-ray spectrometers whose performance requirements do not justify the complexity of a fully compensated system. We report the results of a comprehensive study of the performance characteristics of a driftless GPSC using short time constants with no additional compensation and compare its performance with that of a fully compensated digital system as a function of x-ray energy.
引用
收藏
页码:289 / 293
页数:5
相关论文
共 50 条
  • [21] A large area gas proportional scintillation counter for balloon born solar X-ray spectrometry
    da Luz, HN
    Veloso, JFCA
    dos Santos, JMF
    Conde, CAN
    Silva, RMC
    Pan, HR
    Li, ZY
    Lin, HA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2488 - 2491
  • [22] Enhanced digital spectrometry of gas proportional scintillation counter pulses in x-ray fluorescence applications
    Simoes, PCPS
    dos Santos, JMF
    Conde, CAN
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 452 - 456
  • [24] SOFT-X-RAY ENERGY RESOLUTION AND BACKGROUND REJECTION IN A DRIFTLESS GAS SCINTILLATION PROPORTIONAL COUNTER
    SIMONS, DG
    DEKORTE, PAJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3): : 642 - 656
  • [25] The X-ray performance of a driftless gas proportional scintillation counter using short shaping-time constants for pulse analysis
    Covita, DS
    Simoes, PCPS
    Fernandes, LMP
    Freitas, EDC
    Ferreira, LFR
    Veloso, JFCA
    dos Santos, JMF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (01): : 134 - 142
  • [26] X-ray polarimetry experiment with balloon borne gas proportional counters
    Hayashida, K
    Tsunemi, H
    Horikawa, T
    NEW CENTURY OF X-RAY ASTRONOMY, 2001, 251 : 538 - 539
  • [27] PROPORTIONAL COUNTERS AND COUNTING ELECTRONICS - PRINCIPLES, CONTROL AND ADJUSTMENT IN X-RAY SPECTROMETRY
    MAURICE, F
    RUSTE, J
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1977, 2 (02): : 171 - &
  • [28] THE X-RAY-SPECTRUM OF THE CYGNUS LOOP MEASURED WITH GAS SCINTILLATION PROPORTIONAL-COUNTERS
    TSUNEMI, H
    MANABE, M
    YAMASHITA, K
    KOYAMA, K
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 1988, 40 (04) : 449 - 458
  • [29] NONDISPERSIVE X-RAY ANALYSIS WITH PROPORTIONAL COUNTERS
    HENDEE, CF
    FINE, S
    BROWN, WB
    SPECTROCHIMICA ACTA, 1956, 8 (02): : 112 - 113
  • [30] PROPORTIONAL FLOW X-RAY COUNTERS SRPP
    VLASOV, AD
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (04): : 263 - 263