A simple approach to X-ray spectrometry with driftless gas proportional scintillation counters

被引:0
|
作者
Simoes, PCPS [1 ]
Covita, DS [1 ]
Monteiro, CMB [1 ]
dos Santos, JMF [1 ]
Morgado, RE [1 ]
机构
[1] Univ Coimbra, Dept Phys, P-3004516 Coimbra, Portugal
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Driftless gas proportional scintillation counters are used not only for soft x-ray spectrometry but also for x-rays with energies in the 0.1- to 25-keV region. At the higher energies, however, pulse amplitudes will depend on where the absorption occurred in the detector. Pulse-shape analysis with either analog or digital pulse techniques is required to restore proportionality between the measured pulse and the energy of the x-ray. In this work we describe a simpler approach to driftless gas proportional scintillation counter spectrometry at higher energies. The method eliminates the requirement for additional analog electronics or digital signal processing with only a modest amount of energy-dependent degradation in overall performance. The approach relies on short amplifier time constants and allows tradeoffs in the design of x-ray spectrometers whose performance requirements do not justify the complexity of a fully compensated system. We report the results of a comprehensive study of the performance characteristics of a driftless GPSC using short time constants with no additional compensation and compare its performance with that of a fully compensated digital system as a function of x-ray energy.
引用
收藏
页码:289 / 293
页数:5
相关论文
共 50 条
  • [31] PROPORTIONAL-COUNTERS FOR X-RAY ANALYSIS
    GILAR, O
    PAVLICEK, Z
    JADERNA ENERGIE, 1978, 24 (10): : 375 - 377
  • [32] WAVELENGTH RESOLUTION OF X-RAY PROPORTIONAL COUNTERS
    LANG, AR
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1952, 65 (389): : 372 - 373
  • [33] A gas proportional-scintillation counter for x-ray spectrometry in the 0.1-3 keV range
    Borges, FIGM
    dos Santos, JMF
    Dias, THVT
    Santos, FP
    Conde, CAN
    X-RAY SPECTROMETRY, 2004, 33 (02) : 124 - 127
  • [34] A large area gas proportional scintillation counter for solar X-ray spectrometry in a balloon born experiment
    da Luz, HN
    Veloso, JFCA
    dos Santos, JMF
    Conde, CAN
    Silva, RMC
    Pan, HR
    Li, ZY
    Lin, HA
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 414 - 416
  • [35] SCINTILLATION EFFICIENCY OF GAS PROPORTIONAL SCINTILLATION-COUNTERS
    ALEGRIAFEIO, M
    POLICARPO, A
    CHARPAK, G
    SAULI, F
    NUCLEAR INSTRUMENTS & METHODS, 1980, 176 (03): : 473 - 476
  • [36] A GAS SCINTILLATION PROPORTIONAL COUNTER FOR THE X-RAY ASTRONOMY SATELLITE SAX
    SMITH, A
    PEACOCK, A
    KOWALSKI, TZ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 57 - 61
  • [37] AN IMAGING GAS SCINTILLATION PROPORTIONAL COUNTER FOR USE IN X-RAY ASTRONOMY
    HAILEY, CJ
    KU, WHM
    VARTANIAN, MH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (2-3): : 397 - 410
  • [38] SEALED XENON GAS SCINTILLATION PROPORTIONAL COUNTER FOR X-RAY ASTRONOMY
    ANDRESEN, RD
    KARLSSON, L
    TAYLOR, BG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 473 - 475
  • [39] ACCURATE CALIBRATION OF EFFICIENCIES OF X-RAY DETECTORS - FLOW-PROPORTIONAL AND SCINTILLATION-COUNTERS
    LOOMIS, TC
    KEITH, HD
    APPLIED SPECTROSCOPY, 1975, 29 (04) : 316 - 322
  • [40] GAS DENSITY CONTROL-SYSTEM FOR X-RAY PROPORTIONAL COUNTERS IN SPACE
    SHEATHER, PH
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (09): : 889 - 890