Evaluations of a flat-panel based compact daily quality assurance device for proton pencil beam scanning (PBS) system

被引:10
|
作者
Su, Zhong [1 ,2 ]
Hsi, Wen [1 ,2 ]
Forthomme, Julien [3 ]
Rossomme, Severine [3 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL USA
[2] Univ Florida, Hlth Proton Therapy Inst, 2015 N Jefferson St, Jacksonville, FL 32206 USA
[3] IBA Dosimetry, Schwarzenbruck, Germany
关键词
Proton therapy; Pencil beam scanning (PBS); Daily quality assurance (QA); Flat-panel detector; LINEAR-ENERGY-TRANSFER; DAILY QA; THERAPY; DOSIMETER; IMRT;
D O I
10.1016/j.ejmp.2020.10.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the flat-panel detector quenching effect and clinical usability of a flat-panel based compact QA device for PBS daily constancy measurements. Materials & Method: The QA device, named Sphinx Compact, is composed of a 20x20 cm(2) flat-panel imager mounted on a portable frame with removable plastic modules for constancy checks of proton energy (100 MeV, 150 MeV, 200 MeV), Spread-Out-Bragg-Peak (SOBP) profile, and machine output. The potential quenching effect of the flat-panel detector was evaluated. Daily PBS QA tests of X-ray/proton isocenter coincidence, the constancy of proton spot position and sigma as well as the energy of pristine proton beam, and the flatness of SOBP proton beam through the 'transformed' profile were performed and analyzed. Furthermore, the sensitivity of detecting energy changes of pristine proton beam was also evaluated. Results: The quenching effect was observed at depths near the pristine peak regions. The flat-panel measured range of the distal 80% is within 0.9 mm to the defined ranges of the delivered proton beams. X-ray/proton isocenter coincidence tests demonstrated maximum mismatch of 0.3 mm between the two isocenters. The device can detect 0.1 mm change of spot position and 0.1 MeV energy changes of pristine proton beams. The measured transformed SOBP beam profile through the wedge module rendered as flat. Conclusions: Even though the flat-panel detector exhibited quenching effect at the Bragg peak region, the proton range can still be accurately measured. The device can fulfill the requirements of the daily QA tests recommended by the AAPM TG224 Report.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 50 条
  • [1] Evaluation of a Pencil-Beam Scanning Proton Radiography System Using a Flat-Panel Imager
    Harms, J.
    Maloney, L.
    Sohn, J.
    Lin, Y.
    Gao, H.
    Erickson, A.
    Liu, T.
    Zhang, R.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E475 - E475
  • [2] Flat-panel imager energy-dependent proton radiography for a proton pencil-beam scanning system
    Harms, Joseph
    Maloney, Luke
    Sohn, James J.
    Erickson, Anna
    Lin, Yuting
    Zhang, Rongxiao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (14):
  • [3] Proton Beam Imaging Using X-Ray Flat Panel for a Pencil Beam Scanning System
    Finley, C.
    Jee, K.
    Zwart, T.
    Sharp, G.
    Huo, W.
    Jones, M.
    Huang, K.
    Catanzano, D.
    Nyamane, S.
    Cooley, J.
    Rosenthal, S.
    Lu, H.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3145 - 3145
  • [4] Initial Daily Quality Assurance (QA) Experiences of the Adaptive Aperture in Mevion Hyperscan Proton Pencil Beam Scanning System
    Zhu, X.
    Rashid, A.
    Kang, M.
    Chen, Y.
    Lischalk, J.
    Pang, D.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E592 - E593
  • [5] Auto-Trending daily quality assurance program for a pencil beam scanning proton system aligned with TG 224
    Shi, Chengyu
    Chen, Qing
    Yu, Francis
    Zhang, Jingqiao
    Kang, Minglei
    Tang, Shikui
    Chang, Chang
    Lin, Haibo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 117 - 127
  • [6] Machine Log File Analysis for Quality Assurance of Proton Pencil Beam Scanning System
    Zhang, R.
    Clasie, B.
    Depauw, N.
    Lin, Y.
    Shen, T.
    Flanz, J.
    Lu, H.
    Jee, K.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E264 - E264
  • [7] Detectors for quality assurance of pencil beam scanning gantries for proton therapy
    Gagnon-Moisan, F.
    van der Meer, R.
    Chowdhuri, Z.
    Eichin, M.
    Koenig, S.
    Schmid, F. -J.
    Weber, D. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S44 - S45
  • [8] Investigations of a flat-panel detector for quality assurance measurements in ion beam therapy
    Hartmann, Bernadette
    Telsemeyer, Julia
    Huber, Lucas
    Ackermann, Benjamin
    Jaekel, Oliver
    Martisikova, Maria
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 51 - 68
  • [9] Study of a plastic scintillating plate-based quality assurance system for pencil beam scanning proton beams
    Seo, Jaehyeon
    Chung, Kwangzoo
    Han, Youngyih
    Jeong, Seonghoon
    Jo, Yunhui
    Oh, Geon
    Gi, Yongha
    Sung, Heehun
    Ahn, Sung Hwan
    Yoon, Myonggeun
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (01) : 85 - 92
  • [10] First Quality Assurance Implementation of Treatment Planning System for Pencil Beam Scanning Proton Radiotherapy
    Xiong, W.
    Yu, G.
    Kang, M.
    Huang, S.
    Lin, H.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)