Evaluations of a flat-panel based compact daily quality assurance device for proton pencil beam scanning (PBS) system

被引:10
|
作者
Su, Zhong [1 ,2 ]
Hsi, Wen [1 ,2 ]
Forthomme, Julien [3 ]
Rossomme, Severine [3 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL USA
[2] Univ Florida, Hlth Proton Therapy Inst, 2015 N Jefferson St, Jacksonville, FL 32206 USA
[3] IBA Dosimetry, Schwarzenbruck, Germany
关键词
Proton therapy; Pencil beam scanning (PBS); Daily quality assurance (QA); Flat-panel detector; LINEAR-ENERGY-TRANSFER; DAILY QA; THERAPY; DOSIMETER; IMRT;
D O I
10.1016/j.ejmp.2020.10.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the flat-panel detector quenching effect and clinical usability of a flat-panel based compact QA device for PBS daily constancy measurements. Materials & Method: The QA device, named Sphinx Compact, is composed of a 20x20 cm(2) flat-panel imager mounted on a portable frame with removable plastic modules for constancy checks of proton energy (100 MeV, 150 MeV, 200 MeV), Spread-Out-Bragg-Peak (SOBP) profile, and machine output. The potential quenching effect of the flat-panel detector was evaluated. Daily PBS QA tests of X-ray/proton isocenter coincidence, the constancy of proton spot position and sigma as well as the energy of pristine proton beam, and the flatness of SOBP proton beam through the 'transformed' profile were performed and analyzed. Furthermore, the sensitivity of detecting energy changes of pristine proton beam was also evaluated. Results: The quenching effect was observed at depths near the pristine peak regions. The flat-panel measured range of the distal 80% is within 0.9 mm to the defined ranges of the delivered proton beams. X-ray/proton isocenter coincidence tests demonstrated maximum mismatch of 0.3 mm between the two isocenters. The device can detect 0.1 mm change of spot position and 0.1 MeV energy changes of pristine proton beams. The measured transformed SOBP beam profile through the wedge module rendered as flat. Conclusions: Even though the flat-panel detector exhibited quenching effect at the Bragg peak region, the proton range can still be accurately measured. The device can fulfill the requirements of the daily QA tests recommended by the AAPM TG224 Report.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 50 条
  • [41] Development of a Daily-Treatment Beam-Monitoring System Based Gafchromic EBT3 Film for Pencil-Beam Scanning Proton Therapy
    Jeong, Seonghoon
    Yoon, Myonggeun
    Chung, Kwangzoo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (08) : 769 - 773
  • [42] Beam Characteristics of the First Clinical 360°-rotational Compact Scanning Pencil Beam Proton Treatment System and Comparisons against a Multi-Room System
    Shang, C. Y.
    Evans, G.
    Rahman, M.
    Lin, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E360 - E361
  • [43] Feasibility study of utilizing XRV-124 scintillation detector for quality assurance of spot profile in pencil beam scanning proton therapy
    Rana, Suresh
    Samuel, E. James Jebaseelan
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 66 : 15 - 20
  • [44] Development of Optical Fiber Based Measurement System for the Verification of Entrance Dose Map in Pencil Beam Scanning Proton Beam
    Son, Jaeman
    Lee, Se Byeong
    Lim, Youngkyung
    Park, Sung Yong
    Cho, Kwanho
    Yoon, Myonggeun
    Shin, Dongho
    [J]. SENSORS, 2018, 18 (01):
  • [45] Beam Characteristics of the First Clinical 360-Rotational Compact Scanning Pencil Beam Proton Treatment System and Differences From a Multi-Room System
    Shang, C.
    Evans, G.
    Rahman, M.
    Lin, L.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E709 - E710
  • [46] A comprehensive pre-clinical treatment quality assurance program using unique spot patterns for proton pencil beam scanning FLASH radiotherapy
    Tsai, Pingfang
    Yang, Yunjie
    Wu, Mengjou
    Chen, Chin-Cheng
    Yu, Francis
    Simone II, Charles B.
    Choi, Jehee Isabelle
    Tome, Wolfgang A.
    Lin, Haibo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [47] Evaluation of GATE-RTion (GATE/Geant4) Monte Carlo simulation settings for proton pencil beam scanning quality assurance
    Winterhalter, Carla
    Taylor, Michael
    Boersma, David
    Elia, Alessio
    Guatelli, Susanna
    Mackay, Ranald
    Kirkby, Karen
    Maigne, Lydia
    Ivanchenko, Vladimir
    Resch, Andreas F.
    Sarrut, David
    Sitch, Peter
    Vidal, Marie
    Grevillot, Loic
    Aitkenhead, Adam
    [J]. MEDICAL PHYSICS, 2020, 47 (11) : 5817 - 5828
  • [48] A contrast-detail phantom study to compare a slot scanning digital mammography system with an ASi/CsI flat-panel based system
    Lai, C
    Shaw, C
    Geiser, W
    Liu, X
    Kappadath, S
    Altunbas, M
    Tu, S
    Wang, T
    Whitman, G
    Dempsey, P
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1796 - 1796
  • [49] SDDRO-PBS: Simultaneous Dose and Dose Rate Optimization for FLASH Proton SBRT Based on Pencil Beam Scanning Dose Rate Modeling
    Gao, H.
    Folkerts, M. M.
    Lin, Y.
    Abel, E.
    Bradley, J. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E553 - E553
  • [50] Investigating Aperture-Based Approximations to Model a Dynamic Collimation System for Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Smith, B.
    Culberson, W.
    Flynn, R.
    Hyer, D.
    Rana, S.
    Hill, P.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E802 - E802