High resolution MR eye protocol optimization: Comparison between 3D-CISS, 3D-PSIF and 3D-VIBE sequences

被引:6
|
作者
Tsiapa, Irene [1 ,2 ,4 ]
Tsilimbaris, Miltiadis K. [2 ]
Papadaki, Efrosini [3 ]
Bouziotis, Penelope [4 ]
Pallikaris, Ioannis G. [2 ]
Karantanas, Apostolos H. [3 ]
Maris, Thomas G. [1 ]
机构
[1] Univ Crete, Dept Med Phys, GR-71201 Iraklion, Crete, Greece
[2] Univ Hosp Crete, Dept Ophthalmol, Iraklion, Crete, Greece
[3] Univ Crete, Dept Radiol, GR-71201 Iraklion, Crete, Greece
[4] Natl Ctr Sci Res Demokritos, Inst Nucl & Radiol Sci Technol Energy & Safety, Athens, Greece
来源
关键词
MR eye; Ophthalmology; Ocular tissues; High-resolution MRI; CILIARY MUSCLE; MELANOMA; 1.5-T; COIL; LENS;
D O I
10.1016/j.ejmp.2015.03.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare selected MRI pulse sequences and to evaluate their utility for depicting specific anatomic regions in the eye. Methods: A High-Resolution (HR) 0.08 x 0.08 x 0.60 mm(3) MRI protocol was developed on a 1.5-T clinical system and applied in the left eye of an albino rabbit, utilizing a small field of view surface coil. The comprehensive MRI protocol consisted of two 3D (T2/T1) w sequences (3D-PSIF and 3D-CISS), and one 3D T1w sequence (3D-VIBE). The T1w 3D-VIBE sequence was acquired, before and after intravenous injection of 0.2 mmol/kgr gadolinium-DTPA. Signal-to-Noise Ratios (SNR) and Contrast-to-Noise Ratios (CNR) amongst specific eye anatomical areas were calculated for each sequence. The presence of artifacts was rated subjectively utilizing a 5 point scale. Results: 3D-PSIF and 3D-CISS provide better delineation and visualization of the eye as compared with 3D-VIBE sequences. 3D-CISS images present the highest SNR and revealed better discrimination of the ocular surrounding tissues; its basic drawback though is related to ghost artifacts appearing in the anterior chamber and resulting in the lowest image quality. In post-contrast imaging, the T1w 3D-VIBE sequence provided the best overall image quality. Moreover, 3D (T2/T1) w sequences can provide good anatomic depiction of the eye segments. Agreement between the two independent readers was good. Conclusions: Optimization of a comprehensive MR eye imaging protocol is achieved. A higher SNR, a better spatial resolution and a reduction of the total scan time were obtained, thus making clinical MRI systems more reliable in eye imaging. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:774 / 780
页数:7
相关论文
共 50 条
  • [41] Morphometric analysis of facial and cochlear nerves in normal-hearing ears using 3D-CISS
    Meltem ?zdemir
    Rasime Pelin Kavak
    JournalofOtology, 2019, 14 (04) : 136 - 140
  • [42] Targeting the cranial nerve: microradiosurgery for trigeminal neuralgia with CISS and 3D-Flash MR imaging sequences
    Zerris, VA
    Noren, GC
    Shucart, WA
    Rogg, J
    Friehs, GM
    JOURNAL OF NEUROSURGERY, 2005, 102 : 107 - 110
  • [43] Morphometric analysis of facial and cochlear nerves in normal-hearing ears using 3D-CISS
    Ozdemir, Meltem
    Kavak, Rasime Pelin
    JOURNAL OF OTOLOGY, 2019, 14 (04) : 136 - 140
  • [44] The superiority of 3D-CISS sequence in displaying the cisternal segment of facial, vestibulocochlear nerves and their abnormal changes
    Liang, Changhu
    Zhang, Bin
    Wu, Lebin
    Du, Yinglin
    Wang, Ximing
    Liu, Cheng
    Yu, Fuhua
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : 437 - 440
  • [45] MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences
    Nickolas Papanikolaou
    John Grammatikakis
    Thomas Maris
    Thomas Lauenstein
    Panos Prassopoulos
    Nicholas Gourtsoyiannis
    European Radiology, 2003, 13 : 448 - 452
  • [46] MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences
    Papanikolaou, N
    Grammatikakis, J
    Maris, T
    Lauenstein, T
    Prassopoulos, P
    Gourtsoyiannis, N
    EUROPEAN RADIOLOGY, 2003, 13 (03) : 448 - 452
  • [47] Segmentation of 3D MR image sequences
    Haris, K
    Strintzis, MG
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 425 - 428
  • [48] 3D-CISS序列在儿童脑积水术前诊断中的应用
    谭震
    陈乾
    朱凤军
    臧冬东
    刘健刚
    王靖生
    刘明刚
    中国微侵袭神经外科杂志, 2014, 19 (07) : 296 - 299
  • [49] 3D-CISS序列对颅内表皮样囊肿的诊断价值
    黄劲柏
    徐海波
    孔祥泉
    史河水
    李欣
    吴汉平
    刘定西
    中国医学影像技术, 2005, (11) : 58 - 60
  • [50] 3D-CISS序列诊断脑室、脑池系统疾病的价值
    周旭峰
    陈成立
    中国医学影像学杂志, 2005, (05) : 353 - 355