High resolution MR eye protocol optimization: Comparison between 3D-CISS, 3D-PSIF and 3D-VIBE sequences

被引:6
|
作者
Tsiapa, Irene [1 ,2 ,4 ]
Tsilimbaris, Miltiadis K. [2 ]
Papadaki, Efrosini [3 ]
Bouziotis, Penelope [4 ]
Pallikaris, Ioannis G. [2 ]
Karantanas, Apostolos H. [3 ]
Maris, Thomas G. [1 ]
机构
[1] Univ Crete, Dept Med Phys, GR-71201 Iraklion, Crete, Greece
[2] Univ Hosp Crete, Dept Ophthalmol, Iraklion, Crete, Greece
[3] Univ Crete, Dept Radiol, GR-71201 Iraklion, Crete, Greece
[4] Natl Ctr Sci Res Demokritos, Inst Nucl & Radiol Sci Technol Energy & Safety, Athens, Greece
来源
关键词
MR eye; Ophthalmology; Ocular tissues; High-resolution MRI; CILIARY MUSCLE; MELANOMA; 1.5-T; COIL; LENS;
D O I
10.1016/j.ejmp.2015.03.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare selected MRI pulse sequences and to evaluate their utility for depicting specific anatomic regions in the eye. Methods: A High-Resolution (HR) 0.08 x 0.08 x 0.60 mm(3) MRI protocol was developed on a 1.5-T clinical system and applied in the left eye of an albino rabbit, utilizing a small field of view surface coil. The comprehensive MRI protocol consisted of two 3D (T2/T1) w sequences (3D-PSIF and 3D-CISS), and one 3D T1w sequence (3D-VIBE). The T1w 3D-VIBE sequence was acquired, before and after intravenous injection of 0.2 mmol/kgr gadolinium-DTPA. Signal-to-Noise Ratios (SNR) and Contrast-to-Noise Ratios (CNR) amongst specific eye anatomical areas were calculated for each sequence. The presence of artifacts was rated subjectively utilizing a 5 point scale. Results: 3D-PSIF and 3D-CISS provide better delineation and visualization of the eye as compared with 3D-VIBE sequences. 3D-CISS images present the highest SNR and revealed better discrimination of the ocular surrounding tissues; its basic drawback though is related to ghost artifacts appearing in the anterior chamber and resulting in the lowest image quality. In post-contrast imaging, the T1w 3D-VIBE sequence provided the best overall image quality. Moreover, 3D (T2/T1) w sequences can provide good anatomic depiction of the eye segments. Agreement between the two independent readers was good. Conclusions: Optimization of a comprehensive MR eye imaging protocol is achieved. A higher SNR, a better spatial resolution and a reduction of the total scan time were obtained, thus making clinical MRI systems more reliable in eye imaging. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:774 / 780
页数:7
相关论文
共 50 条
  • [21] Clinical Application of 3D-CISS MRI Sequences for Diagnosis and Surgical Planning of Spinal Arachnoid Diverticula and Adhesions in Dogs
    Tauro, Anna
    Jovanovik, Jelena
    Driver, Colin John
    Rusbridge, Clare
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2018, 31 (02) : 83 - 94
  • [22] Comparison between high-resolution 3D-IR with real reconstruction and 3D-flair sequences in the assessment of endolymphatic hydrops in 3 tesla
    Suarez Vega, Victor Manuel
    Dominguez, Pablo
    Caballeros Lam, Fanny Meylin
    Leal, Jose Ignacio
    Perez-Fernandez, Nicolas
    ACTA OTO-LARYNGOLOGICA, 2020, 140 (11) : 883 - 888
  • [23] SPECTROSCOPY AND 3D-CISS SEQUENCE IN CYSTIC LESIONS OF BRAIN: A PROSPECTIVE EVALUATION ON MRI
    Bhuyan, Mary Hazarika
    Bhuyan, R. K.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (74): : 5463 - 5469
  • [24] Comparison of Modern 3D and 2D MR Imaging Sequences of the Wrist at 3 Tesla
    Rehnitz, C.
    Klaan, B.
    von Stillfried, F.
    Amarteifio, E.
    Burkholder, I.
    Kauczor, H. U.
    Weber, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (08): : 753 - 762
  • [25] 3D-CISS序列与3D-TSE序列对ⅦⅨ对颅神经成像质量的比较
    梁长虎
    柳澄
    李坤成
    黄杰
    乌大尉
    王海燕
    赵振美
    医学影像学杂志, 2007, (09) : 891 - 894
  • [26] The contribution of 3D-CISS and contrast-enhanced MR cisternography in detecting cerebrospinal fluid leak in patients with rhinorrhoea
    Algin, O.
    Hakyemez, B.
    Gokalp, G.
    Ozcan, T.
    Korfali, E.
    Parlak, M.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (987): : 225 - 232
  • [27] Radiosurgery of vestibular schwannoma: prognostic factors for hearing outcome using 3D-constructive interference in steady state (3D-CISS)
    Wagner, Franca
    Gandalini, Matteo
    Hakim, Arsany
    Ermis, Ekin
    Leiser, Dominic
    Zbinden, Martin
    Anschuetz, Lukas
    Raabe, Andreas
    Caversaccio, Marco
    Wiest, Roland
    Herrmann, Evelyn
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (12) : 1132 - 1143
  • [28] DCE-MRI of esophageal carcinoma using star-VIBE compared with conventional 3D-VIBE
    Deng, He-Ping
    Li, Xue-Ming
    Yang, Liu
    Wang, Yi
    Wang, Shao-Yu
    Zhou, Peng
    Lu, Yu-Jie
    Ren, Jin
    Wang, Min
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [29] Internal Auditory Canal (IAC) and Cerebellopontine Angle (CPA): Comparison between T2-weighted SPACE and 3D-CISS sequences at 1.5T
    Makhamrah, Osama
    Ahmad, Muntaser S.
    Doufish, Dania
    Mohammad, Hjouj
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [30] Radiosurgery of vestibular schwannoma: prognostic factors for hearing outcome using 3D-constructive interference in steady state (3D-CISS)Radiochirurgie bei Vestibularisschwannom: Prognostische Faktoren für das Hörvermögen bei Akquisition der 3D-CISS
    Franca Wagner
    Matteo Gandalini
    Arsany Hakim
    Ekin Ermis
    Dominic Leiser
    Martin Zbinden
    Lukas Anschuetz
    Andreas Raabe
    Marco Caversaccio
    Roland Wiest
    Evelyn Herrmann
    Strahlentherapie und Onkologie, 2018, 194 : 1132 - 1143