High resolution MR eye protocol optimization: Comparison between 3D-CISS, 3D-PSIF and 3D-VIBE sequences

被引:6
|
作者
Tsiapa, Irene [1 ,2 ,4 ]
Tsilimbaris, Miltiadis K. [2 ]
Papadaki, Efrosini [3 ]
Bouziotis, Penelope [4 ]
Pallikaris, Ioannis G. [2 ]
Karantanas, Apostolos H. [3 ]
Maris, Thomas G. [1 ]
机构
[1] Univ Crete, Dept Med Phys, GR-71201 Iraklion, Crete, Greece
[2] Univ Hosp Crete, Dept Ophthalmol, Iraklion, Crete, Greece
[3] Univ Crete, Dept Radiol, GR-71201 Iraklion, Crete, Greece
[4] Natl Ctr Sci Res Demokritos, Inst Nucl & Radiol Sci Technol Energy & Safety, Athens, Greece
来源
关键词
MR eye; Ophthalmology; Ocular tissues; High-resolution MRI; CILIARY MUSCLE; MELANOMA; 1.5-T; COIL; LENS;
D O I
10.1016/j.ejmp.2015.03.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare selected MRI pulse sequences and to evaluate their utility for depicting specific anatomic regions in the eye. Methods: A High-Resolution (HR) 0.08 x 0.08 x 0.60 mm(3) MRI protocol was developed on a 1.5-T clinical system and applied in the left eye of an albino rabbit, utilizing a small field of view surface coil. The comprehensive MRI protocol consisted of two 3D (T2/T1) w sequences (3D-PSIF and 3D-CISS), and one 3D T1w sequence (3D-VIBE). The T1w 3D-VIBE sequence was acquired, before and after intravenous injection of 0.2 mmol/kgr gadolinium-DTPA. Signal-to-Noise Ratios (SNR) and Contrast-to-Noise Ratios (CNR) amongst specific eye anatomical areas were calculated for each sequence. The presence of artifacts was rated subjectively utilizing a 5 point scale. Results: 3D-PSIF and 3D-CISS provide better delineation and visualization of the eye as compared with 3D-VIBE sequences. 3D-CISS images present the highest SNR and revealed better discrimination of the ocular surrounding tissues; its basic drawback though is related to ghost artifacts appearing in the anterior chamber and resulting in the lowest image quality. In post-contrast imaging, the T1w 3D-VIBE sequence provided the best overall image quality. Moreover, 3D (T2/T1) w sequences can provide good anatomic depiction of the eye segments. Agreement between the two independent readers was good. Conclusions: Optimization of a comprehensive MR eye imaging protocol is achieved. A higher SNR, a better spatial resolution and a reduction of the total scan time were obtained, thus making clinical MRI systems more reliable in eye imaging. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:774 / 780
页数:7
相关论文
共 50 条
  • [31] Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis
    Algin, Oktay
    Hakyemez, Bahattin
    Parlak, Mufit
    NEURORADIOLOGY, 2010, 52 (02) : 99 - 108
  • [32] Glenoid bone lesions: Comparison between 3D VIBE images in MR arthrography and nonarthrographic MSCT
    Tian, Chun-Yan
    Shang, Yao
    Zheng, Zhuo-Zhao
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (01) : 231 - 236
  • [33] Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis
    Oktay Algin
    Bahattin Hakyemez
    Mufit Parlak
    Neuroradiology, 2010, 52 : 99 - 108
  • [34] 磁共振3D-SPACE序列与3D-CISS序列对Ⅴ~Ⅷ颅神经成像的对照性研究
    杜春华
    吴飞云
    祝因苏
    张伟
    刘波
    杨正强
    临床放射学杂志, 2012, 31 (12) : 1699 - 1702
  • [35] MRI of inner ear anatomy using 3D MP-RAGE and 3D CISS sequences
    Held, P
    Fellner, C
    Fellner, F
    Seitz, J
    Strutz, J
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (833): : 465 - 472
  • [36] T2-WEIGHTED MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A RAPID 3D-PSIF SEQUENCE IN 72 PATIENTS
    TAUPITZ, MC
    SPEIDEL, A
    HAMM, B
    DEIMLING, M
    BOCK, A
    WOLF, K
    RADIOLOGY, 1992, 185 : 140 - 140
  • [37] MR imaging of the neural foramina of the cervical spine -: Comparison of 3D-DESS and 3D-FISP sequences
    Muhle, C
    Ahn, JM
    Biederer, J
    Schäfer, FKW
    Frahm, CH
    Mohr, A
    Brossmann, J
    Resnick, D
    ACTA RADIOLOGICA, 2002, 43 (01) : 96 - 100
  • [38] MR enteroclysis protocol optimization: comparison between 3D FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences
    Nicholas Gourtsoyiannis
    Nickolas Papanikolaou
    John Grammatikakis
    Thomas Maris
    Panos Prassopoulos
    European Radiology, 2001, 11 : 908 - 913
  • [39] MR enteroclysis protocol optimization: comparison between 3D FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences
    Gourtsoyiannis, N
    Papanikolaou, N
    Grammatikakis, J
    Maris, T
    Prassopoulos, P
    EUROPEAN RADIOLOGY, 2001, 11 (06) : 908 - 913
  • [40] Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography for the detection of spontaneous third ventriculostomy
    Algin, O.
    Hakyemez, B.
    Parlak, M.
    JOURNAL OF NEURORADIOLOGY, 2011, 38 (02) : 98 - 104