High resolution MR eye protocol optimization: Comparison between 3D-CISS, 3D-PSIF and 3D-VIBE sequences

被引:6
|
作者
Tsiapa, Irene [1 ,2 ,4 ]
Tsilimbaris, Miltiadis K. [2 ]
Papadaki, Efrosini [3 ]
Bouziotis, Penelope [4 ]
Pallikaris, Ioannis G. [2 ]
Karantanas, Apostolos H. [3 ]
Maris, Thomas G. [1 ]
机构
[1] Univ Crete, Dept Med Phys, GR-71201 Iraklion, Crete, Greece
[2] Univ Hosp Crete, Dept Ophthalmol, Iraklion, Crete, Greece
[3] Univ Crete, Dept Radiol, GR-71201 Iraklion, Crete, Greece
[4] Natl Ctr Sci Res Demokritos, Inst Nucl & Radiol Sci Technol Energy & Safety, Athens, Greece
来源
关键词
MR eye; Ophthalmology; Ocular tissues; High-resolution MRI; CILIARY MUSCLE; MELANOMA; 1.5-T; COIL; LENS;
D O I
10.1016/j.ejmp.2015.03.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare selected MRI pulse sequences and to evaluate their utility for depicting specific anatomic regions in the eye. Methods: A High-Resolution (HR) 0.08 x 0.08 x 0.60 mm(3) MRI protocol was developed on a 1.5-T clinical system and applied in the left eye of an albino rabbit, utilizing a small field of view surface coil. The comprehensive MRI protocol consisted of two 3D (T2/T1) w sequences (3D-PSIF and 3D-CISS), and one 3D T1w sequence (3D-VIBE). The T1w 3D-VIBE sequence was acquired, before and after intravenous injection of 0.2 mmol/kgr gadolinium-DTPA. Signal-to-Noise Ratios (SNR) and Contrast-to-Noise Ratios (CNR) amongst specific eye anatomical areas were calculated for each sequence. The presence of artifacts was rated subjectively utilizing a 5 point scale. Results: 3D-PSIF and 3D-CISS provide better delineation and visualization of the eye as compared with 3D-VIBE sequences. 3D-CISS images present the highest SNR and revealed better discrimination of the ocular surrounding tissues; its basic drawback though is related to ghost artifacts appearing in the anterior chamber and resulting in the lowest image quality. In post-contrast imaging, the T1w 3D-VIBE sequence provided the best overall image quality. Moreover, 3D (T2/T1) w sequences can provide good anatomic depiction of the eye segments. Agreement between the two independent readers was good. Conclusions: Optimization of a comprehensive MR eye imaging protocol is achieved. A higher SNR, a better spatial resolution and a reduction of the total scan time were obtained, thus making clinical MRI systems more reliable in eye imaging. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:774 / 780
页数:7
相关论文
共 50 条
  • [1] 3D MR Cisternography to Identify Distal Dural Rings: Comparison of 3D-CISS and 3D-SPACE Sequences
    Watanabe, Yoshiyuki
    Makidono, Akari
    Nakamura, Miho
    Saida, Yukihisa
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (01) : 29 - 32
  • [2] Detection of the Stellate and Thoracic Sympathetic Chain Ganglia with High-Resolution 3D-CISS MR Imaging
    Chaudhry, A.
    Kamali, A.
    Herzka, D. A.
    Wang, K. C.
    Carrino, J. A.
    Blitz, A. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (08) : 1550 - 1554
  • [3] MR diagnosis of CSF fistulas using a 3D-CISS sequence.
    Eberhardt, KEW
    Deimling, M
    Hollenbach, HP
    Huk, WJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (06): : 605 - 611
  • [4] 2D and 3D-CISS imaging of cranial nerves
    Brechtelsbauer, D
    Bendszus, M
    Hofmann, E
    Warmuth-Metz, M
    Solymosi, L
    RIVISTA DI NEURORADIOLOGIA, 1999, 12 : 179 - 182
  • [5] Evaluation of schwannoma using the 3D-SPACE sequence: comparison with the 3D-CISS sequence in 3T-MRI
    Gurun, Enes
    Akdulum, Ismail
    Kilic, Pinar
    Tokgoz, Nil
    Ucar, Murat
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2021, 51 (03) : 1129 - 1135
  • [6] MR 3D-CISS序列对脊髓AVM的诊断价值
    熊茵
    孔祥泉
    徐海波
    刘定西
    于群
    常时新
    戴文
    医学影像学杂志, 2004, (06) : 436 - 438
  • [7] 3D-CISS MRI in a purely intracanalicular cochlear schwannoma
    Thomas, B.
    Krishnamoorthy, T.
    Arvinda, H. R.
    Kesavadas, C.
    JOURNAL OF NEURORADIOLOGY, 2008, 35 (05) : 305 - 307
  • [8] Identification and anatomic description of the anterior choroidal artery by use of 3D-TOF source and 3D-CISS MR imaging
    Wiesmann, M
    Yousry, I
    Seelos, KC
    Yousry, TA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (02) : 305 - 310
  • [9] 3D-SPACE与3D-CISS序列内耳成像的比较研究
    程亚宝
    范伟雄
    刘可夫
    孙岩
    中国中西医结合影像学杂志, 2016, 14 (02) : 146 - 149
  • [10] Signal Alteration of the Cochlear Perilymph on 3 Different Sequences after Intratympanic Gd-DTPA Administration at 3 Tesla: Comparison of 3D-FLAIR, 3D-T1-weighted Imaging, and 3D-CISS
    Yamazaki, Masahiro
    Naganawa, Shinji
    Kawai, Hisashi
    Nihashi, Takashi
    Nakashima, Tsutomu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (02) : 65 - 71