Flowability measurements of pharmaceutical powder mixtures with poor flow using five different techniques

被引:65
|
作者
Lindberg, NO
Pålsson, M
Pihl, AC
Freeman, R
Freeman, T
Zetzener, H
Enstad, G
机构
[1] Pharmacia Consumer Healthcare, Pharmaceut R&D, Helsingborg, Sweden
[2] Freeman Technol, Coulters Farm Ctr, Malvern, Worcs, England
[3] Telemark Technol Res & Dev Ctr, Porsgrunn, Norway
关键词
flowability; pharmaceutical; poor flow; uniaxial tester; Jenike tester;
D O I
10.1081/DDC-120040343
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Four different tablet formulations for direct compression with poor flow properties were tested regarding flowability using five different techniques: Hausner ratio, avalanching behavior, powder rheometer, uniaxial tester, and Jenike tester. In addition, the behavior of three of the formulations during emptying of the mixer and tableting was observed and compared to the results of the flowability measurements. The rank order correlation of the formulations was generally the same with all techniques. The flow properties measured by the different techniques reflected the behavior during processing of the powder mixtures.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [21] Assessment of blending performance of pharmaceutical powder mixtures in a continuous mixer using Discrete Element Method (DEM)
    Behjani, Mohammadreza Alizadeh
    Motlagh, Yousef Ghaffari
    Bayly, Andrew E.
    Hassanpour, Ali
    POWDER TECHNOLOGY, 2020, 366 : 73 - 81
  • [22] Comparison of void fraction measurements using different techniques in two-phase flow bubble column reactors
    Hernandez-Alvarado, Freddy
    Kleinbart, Simon
    Kalaga, Dinesh V.
    Banerjee, Sanjoy
    Joshi, Jyeshtharaj B.
    Kawaji, Masahiro
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2018, 102 : 119 - 129
  • [23] A comparison of ocular blood flow measurements using two different techniques; Pulsatile ocular blood flow and color Doppler imaging.
    Chung, HS
    Harris, A
    McNulty, L
    Evans, DW
    Kagemann, L
    Kagemann, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4891 - 4891
  • [24] Measuring the Flow Functions of Pharmaceutical Powders Using the Brookfield Powder Flow Tester and Freeman FT4
    Leaper, Mark Christopher
    PROCESSES, 2021, 9 (11)
  • [25] Assessing the diet of great skuas, Catharacta skua, using five different techniques
    Stephen C. Votier
    Stuart Bearhop
    Aidan MacCormick
    Norman Ratcliffe
    Robert W. Furness
    Polar Biology, 2003, 26 : 20 - 26
  • [26] Modeling pharmaceutical powder-flow performance using particle-size distribution data
    Pfizer, Inc., Eastern Point Rd., Groton, CT 06340, United States
    Pharm. Technol., 2009, 3 (126-134):
  • [27] Assessing the diet of great skuas, Catharacta skua, using five different techniques
    Votier, SC
    Bearhop, S
    MacCormick, A
    Ratcliffe, N
    Furness, RW
    POLAR BIOLOGY, 2003, 26 (01) : 20 - 26
  • [28] Evaluating the Durability of Asphalt Mixtures for Flexible Pavement Using Different Techniques: A Review
    Al-Taher, Metwally G.
    Sawan, Ahmed M.
    Solyman, Mahmoud El-Saied Ali
    Attia, Mohamed Ibrahim El-Sharkawi
    Ibrahim, Mokhtar F.
    INTERNATIONAL JOURNAL OF PAVEMENT RESEARCH AND TECHNOLOGY, 2024,
  • [29] An overview of qualimetric strategies for optimisation and calibration in pharmaceutical analysis using flow injection techniques
    Bosque-Sendra, JM
    Gámiz-Gracia, L
    García-Campaña, AM
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (05) : 863 - 874
  • [30] An overview of qualimetric strategies for optimisation and calibration in pharmaceutical analysis using flow injection techniques
    J. M. Bosque-Sendra
    L. Gámiz-Gracia
    A. M. García-Campaña
    Analytical and Bioanalytical Chemistry, 2003, 377 : 863 - 874