Flowability measurements of pharmaceutical powder mixtures with poor flow using five different techniques

被引:65
|
作者
Lindberg, NO
Pålsson, M
Pihl, AC
Freeman, R
Freeman, T
Zetzener, H
Enstad, G
机构
[1] Pharmacia Consumer Healthcare, Pharmaceut R&D, Helsingborg, Sweden
[2] Freeman Technol, Coulters Farm Ctr, Malvern, Worcs, England
[3] Telemark Technol Res & Dev Ctr, Porsgrunn, Norway
关键词
flowability; pharmaceutical; poor flow; uniaxial tester; Jenike tester;
D O I
10.1081/DDC-120040343
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Four different tablet formulations for direct compression with poor flow properties were tested regarding flowability using five different techniques: Hausner ratio, avalanching behavior, powder rheometer, uniaxial tester, and Jenike tester. In addition, the behavior of three of the formulations during emptying of the mixer and tableting was observed and compared to the results of the flowability measurements. The rank order correlation of the formulations was generally the same with all techniques. The flow properties measured by the different techniques reflected the behavior during processing of the powder mixtures.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [31] COMPARISON OF CEPHALIC BLOOD-FLOW MEASUREMENTS USING 2 TECHNIQUES
    MEYER, MW
    SMITH, KA
    TRIPP, MR
    FOX, IJ
    JOURNAL OF DENTAL RESEARCH, 1975, 54 : 109 - 109
  • [32] Local two-phase flow measurements using sensor techniques
    Hogsett, S
    Ishii, M
    NUCLEAR ENGINEERING AND DESIGN, 1997, 175 (1-2) : 15 - 24
  • [33] Glidant effect of hydrophobic and hydrophilic nanosilica on a cohesive powder: Comparison of different flow characterization techniques
    Bin Ruzaidi, Ahmad Fahmi
    Mandal, Uttam Kumar
    Chatterjee, Bappaditya
    PARTICUOLOGY, 2017, 31 : 69 - 79
  • [34] Soil solution electrical conductivity measurements using different dielectric techniques
    Hamed, Y
    Persson, M
    Berndtsson, R
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2003, 67 (04) : 1071 - 1078
  • [35] Study of powder flow patterns in a Couette cell with axial flow using tracers and solid fraction measurements
    M. Kheiripour Langroudi
    P. R. Mort
    G. I. Tardos
    Granular Matter, 2011, 13 : 541 - 552
  • [36] Study of powder flow patterns in a Couette cell with axial flow using tracers and solid fraction measurements
    Langroudi, M. Kheiripour
    Mort, P. R.
    Tardos, G. I.
    GRANULAR MATTER, 2011, 13 (05) : 541 - 552
  • [37] MEASUREMENTS OF 2-PHASE MASS-FLOW RATE - A COMPARISON OF DIFFERENT TECHNIQUES
    REIMANN, J
    JOHN, H
    MULLER, U
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1982, 8 (01) : 33 - 46
  • [38] Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method
    Shi, Zhenqi
    Igne, Benoit
    Bondi, Robert W., Jr.
    Drennen, James K., III
    Anderson, Carl A.
    APPLIED SPECTROSCOPY, 2012, 66 (09) : 1075 - 1081
  • [39] Simultaneous determination of metronidazole and spiramycin in bulk powder and in tablets using different spectrophotometric techniques
    Khattab, Fatma I.
    Ramadan, Nesrin K.
    Hegazy, Maha A.
    Ghoniem, Nermine S.
    DRUG TESTING AND ANALYSIS, 2010, 2 (1-2) : 37 - 44
  • [40] COMPARATIVE STUDY OF FIVE DIFFERENT SURGICAL TECHNIQUES FOR THE TREATMENT OF MORBID OBESITY USING BAROS
    Marchesini, Joao Batista
    Nicareta, Jean Ricardo
    ABCD-ARQUIVOS BRASILEIROS DE CIRURGIA DIGESTIVA-BRAZILIAN ARCHIVES OF DIGESTIVE SURGERY, 2014, 27 : 17 - 20